SX-2000 VS ICS Commissioning 
Chart 3-l Install Circuit Cards and Load Commissioning Software 
(continued) 
Step Action Comments 
12. The system returns the following prompt: While the system is waiting for 
TIME 0O:nn:nn (where ‘n’ is a digit, O-9) input, it is also reading from 
 sequential RAM locations in order 
to check the RAM refresh circuitry. 
indicating that the active Main Control is ready for If a RAM location loses its refresh, 
testing. a bus error is likely to occur. The 
Any...

Page 62

Commissioning 
l NOTES: A 15 PlCs 81e used, hen cnk DSU 1 may be Itied 
lfDSU1 and DSUZarerquired,then Pic15mustnatbeirslaUed. 
II DSU 1, DSU 2 and DSU 3 are required, then PIC 13, PIC 14 and PIC 15 must not be ihst&ed. 
204 3-4 
Figure 3-l SX-2OOOVS Circuit Card Locations 
Revision 0 9125-060-204-NA 
Issue 1  

Page 63

m IA 
SX-2000 VS ICS Commissioninn 
Control and Peripheral Card Tests 
3.2 Control and Peripheral Interface card tests are performed on the SX-2OOOVS system 
as described in the following chart. 
Chart 3-2 SX-2OOUVS ICS Control and Peripheral interface Card Tests 
EXTERNAL ON Enable external device testing; 
Enable hard disk testing. 
The EXTERNAL ON command is 
not possible if the RECORD tab is 
not in the RECORD position on the 
Testing of mass storage devices is 
disabled by issuing one of the...

Page 64

Commissioning 
Chart 3-2 SX-ZOOOVS ICS Control and Peripheral interface Card Tests 
(continued) 
Step Action Comments 
5. Test PlCs on Shelf 1 by entering: 
STEST Suppress all previous testing. 
ETEST 9-l 1 Enable testing of slots 9 - 11. 
TEST Test cards in slots 9 - 11. 
The system responds as in step 4, and then proceeds If errors are detected, error 
to the next slot. messages are returned. Reinsert 
the card and test again. Replace 
any cards which fail the second 
test. 
6. Test PlCs on Shelf 2 by...

Page 65

m IA 
SX-2000 VS ICS Commissioning 
Maintenance and Hard Disk (MHD) Card Commissioning 
3.3 Commissioning of the MHD card is performed on the SX-2000 VS system as 
described in the following chart. 
Chart 3-3 SX-2000 VS Maintenance and Hard Disk (MHD) Card Commissioning 
The system delivers the following message: If there is an Option Module 
installed, the message will read: 
SYS ID MODULE PRESENT 
Visual led test: Minor, Major, Critical, All ON, OFF 
Perform the following visual checks: 
l Minor ALARM...

Page 66

204 3-6 
Revision 0 9125-060-204-NA Issue 1  

Page 67

4 
. sx-2000 s ICS 
COMMISSIONING 
Install Circuit Cards 
Non-Redundant System 
Ensure that the Main and Peripheral Control cards, and the Peripheral Interface and 
DSU cards are installed in the correct card slots before loading the commissioning 
software. Chart 4-1 describes the card installation procedure for a non-redundant 
SX-2000 S system. 
Chart 4-1 Install Circuit Cards on a Non-Redundant SX-2UUll S ICS 
l Peripheral Switch Controller: Shelf 1, Slot 16 
Insert all Digital Service Units (DSUs)...

Page 68

Commissioning 
Step 
6. 
7. 
8. 
9. Chart 4-l Install Circuit Cards on a Non-Redundant SX-2000 S ICS 
(continued) 
Action 
In a multi-cabinet system, ensure that the Peripheral 
Switch Controller is installed in Shelf 1 Slot 16 of each 
additional cabinet. Comments 
Apply power to Shelf 1 of the next cabinet by setting 
the power switch to ON for the Shelf 1 Power 
Converter of that cabinet. 
Check that the Peripheral Switch Controller card 
begins power-up self-tests, as in Step 5 above. 
Repeat Steps 6...

Page 69

r 
m IA 
SX-2000 S ICS Commissioning 
Chart 4-2 Install Circuit Cards on a Redundant SX-2000 S ICS 
(continued) 
card. Reset the card by pressing 
PANEL ENABLE and LOAD (for 
the affected Plane) on the 
Maintenance Panel. If the card fails 
self-test a second time, replace it. 
Power-up self tests are only 
l Main Controller: Shelf 2, Slot 20 
l Control RAM II Card (optional): Shelf 2, Slot 19 
11. If one or more peripheral cabinets is also provided, Refer to Figure 4-l. 
insert the following cards in...

Page 70

Commissioning 
Chart 4-2 install Circuit Cards on a Redundant SX-2000 S ICS 
(continued) 
Step 
Action Comments 
12. Insert all Peripheral interface Cards (PICs) into their Slots 1 through 12 on each shelf in 
appropriate slots, in each peripheral cabinet. each cabinet. Refer to Figure 4-l. 
13;’ Ins&t all Digital Service Units (DSUs) into their 
appropriate slots, in each peripheral cabinet. Slot 17 on each shelf, except in 
Cabinet 4, if installed. Refer to 
Figure 4-l. 
14. Apply power to Shelf 1 in...