Page 171
CDE Form Descriptions EXT NUM: This field displays the assigned extension number of a data line. COS: This field lists the Class-of-Service number specification of each device (1 to 50). COR: This field lists the Class-of-Restriction number specification of each device (1 to 25). CDN: This field lists the Circuit Descriptor Number assigned to a device (I to 25). DTE: This field lists the Data Terminal Equipment Profile number (I to 25). A data device must have a DTE Profile number to access a...
Page 172
Customer Data Entry and circuit numbers for the first and last devices. The entry is completed by pressing the ENTER softkey. When the extension number for the first device is entered, the system automatically assigns incremented extension numbers, the same COS, COR, CDN, and DTE for each device in the block. A dual circuit dataset cannot be included in range programming. DELETE FIELD: This softkey appears when the cursor is positioned in the AVL or HOTLINE field, when a value has been already...
Page 173
CDE Form Descriptions Field Descriptions DESCRIPTOR: This field lists the trunk circuit descriptors, numbers 01 to 25 (maximum of 25 different descriptors in total). TRUNK TYPE: This field lists trunk circuit type for each trunk circuit descriptor. Note that the selected trunk type (the one that appears on the command line) is not displayed on the softkeys. Note: Trunk type cannot be changed if there are 1 or more trunks assigned to the descriptor. NUMBER OF TRKS ASSIGNED: This field records the...
Page 174
Customer Data Entry Tl E&M DISA: This softkey appears when the MORE softkey has been pressed for the second time. Pressing this softkey defines the selected trunk circuit descriptor as a Ti Trunk simulating an E&M DISA Trunk. Tl LS/GS: This softkey appears when the MORE softkey has been pressed for the second time. Pressing this softkey defines the selected trunk circuit descriptor as a Tl Trunk simulating an LS/GS Trunk. Tl TIE DISA: This softkey appears when the MORE softkey has been pressed for...
Page 175
CDE Form Descriptions Field Descriptions The header line displays the trunk type, the trunk circuit descriptor number and the type of parameter under observation. STATUS: This field lists the option selected for each parameter. Softkeys YES, NO, COMPLEX, 600 OHM, 60/40, IMMEDIATE: This softkey toggles the status of the parameters. 30/20, WINK: This softkey toggles the status of the parameters. 66/33, DELAY: This softkey toggles the status of the parameters. DELAY INTEG: This softkey toggles the...
Page 176
Customer Data Entry 4-66 Table 4-7 Trunk Options (continued) 6-CIRCUIT CO TRUNK and 6-CIRCUIT DISA Reverse to Idle Far-End Gives Answer Supervision Inhibit Automatic Supervision No Seize Alarm No Release Alarm Toll Office Is this a CO DTMF Save Busy-Out Status Impedance (600 Ohm or Complex) Post Call Metering (0 + 15 seconds) Calling Party Disconnect Timer (1 + 12 minutes) Dictation Trunk Ignore Remote Disconnect Disconnect Timer (100 -+ 9900 ms) (100 ms increments) Supervision...
Page 177
CDE Form Descriptions Table 4-7 Trunk Options (continued) Tl DID/TIE and Ti TIE DISA Reverse to Idle Far-End Gives Answer Supervision Inhibit Automatic Supervision No Seize Alarm No Release Alarm Toll Office Is this a CO DTMF Save Busy-Out Status Disconnect Timer (I 50 -+ 300 ms) (50 ms inc) Release Acknowledge Timer (2 + 120 s) Guard Timer (200 + 1000 ms) (100 ms inc) Incoming Start Type (lmmed, Wink or Delay) Debounce Timer (20 + 150 ms) (10 ms inc) Wink Timer (150 + 300 ms) (50 ms...
Page 178
Customer Data Entry 4-68 Table 4-7 Trunk Options (continued) Tl LS/GS TRUNK and Tl CO DISA No Seize Alarm No Release Alarm Toll Office Is this a CO DTMF Save Busy-Out Status Loop Start or Ground Start (Tl LS, Tl GS) Calling Party Disconnect Timer (1 + 12 minutes) Disconnect Timer 100 + 9900 ms (100 ms inc) Guard Timer (0 + 3000 ms) (100 ms inc) Ring Cycle Timer (6 + 10 s) Ringing Expected Ringing Debounce Timer (5 + 12 seconds) Seize Timer (10 + 60 s) (10 s increments) Flash Timer (200...
Page 179
CDE Form Descriptions Flash Type: Specifies whether the flash will be done by opening the current loop (Loop Flash) or grounding the ring (Ring Ground). Guard Timer: This defines how long the system will wait after releasing the trunk before seizing it again for an outgoing call. Ignore Line Reversal During Seizure: If selected, line reversal is not recognized as an incoming seizure. Ignore Remote Disconnect: If selected, release signals from the far-end are ignored. If not selected, release...
Page 180
Customer Data Entry Remote End is a Satellite: Select if the trunk is to terminate at a satellite PABX. Refer to the Engineering hformhon /+actice for details of loss/gain. Remote End is a Satellite with OPS Lines: Select if the trunk is to terminate at a satellite PABX with OPS lines. Refer to the Engineering hforrrmtion practice for details of loss/gain. Reverse to Idle: In some central offices, upon seizure, the CO reverses the polarity on the trunk. When the call ends, the CO again reverses...