Page 171

CDE Form Descriptions 
EXT NUM: This field displays the assigned extension number of a data line. 
COS: This field lists the Class-of-Service number specification of each device (1 to 50). 
COR: This field lists the Class-of-Restriction number specification of each device (1 
to 25). 
CDN: This field lists the Circuit Descriptor Number assigned to a device (I to 25). 
DTE: This field lists the Data Terminal Equipment Profile number (I to 25). A data 
device must have a DTE Profile number to access a...

Page 172

Customer Data Entry 
and circuit numbers for the first and last devices. The entry is completed by pressing 
the ENTER softkey. When the extension number for the first device is entered, the 
system automatically assigns incremented extension numbers, the same COS, COR, 
CDN, and DTE for each device in the block. A dual circuit dataset cannot be included 
in range programming. 
DELETE FIELD: This softkey appears when the cursor is positioned in the AVL or 
HOTLINE field, when a value has been already...

Page 173

CDE Form Descriptions 
Field Descriptions 
DESCRIPTOR: This field lists the trunk circuit descriptors, numbers 01 to 25 (maximum 
of 25 different descriptors in total). 
TRUNK TYPE: This field lists trunk circuit type for each trunk circuit descriptor. Note 
that the selected trunk type (the one that appears on the command line) is not displayed 
on the softkeys. Note: Trunk type cannot be changed if there are 1 or more trunks 
assigned to the descriptor. 
NUMBER OF TRKS ASSIGNED: This field records the...

Page 174

Customer Data Entry 
Tl E&M DISA: This softkey appears when the MORE softkey has been pressed for 
the second time. Pressing this softkey defines the selected trunk circuit descriptor as 
a Ti Trunk simulating an E&M DISA Trunk. 
Tl LS/GS: This softkey appears when the MORE softkey has been pressed for the 
second time. Pressing this softkey defines the selected trunk circuit descriptor as a Tl 
Trunk simulating an LS/GS Trunk. 
Tl TIE DISA: This softkey appears when the MORE softkey has been pressed for...

Page 175

CDE Form Descriptions 
Field Descriptions 
The header line displays the trunk type, the trunk circuit descriptor number and the 
type of parameter under observation. 
STATUS: This field lists the option selected for each parameter. 
Softkeys 
YES, NO, COMPLEX, 600 OHM, 60/40, IMMEDIATE: This softkey toggles the status 
of the parameters. 
30/20, WINK: This softkey toggles the status of the parameters. 
66/33, DELAY: This softkey toggles the status of the parameters. 
DELAY INTEG: This softkey toggles the...

Page 176

Customer Data Entry 
4-66 Table 4-7 Trunk Options (continued) 
6-CIRCUIT CO TRUNK and 6-CIRCUIT DISA 
Reverse to Idle 
Far-End Gives Answer Supervision 
Inhibit Automatic Supervision 
No Seize Alarm 
No Release Alarm 
Toll Office 
Is this a CO 
DTMF 
Save Busy-Out Status 
Impedance (600 Ohm or Complex) 
Post Call Metering (0 + 15 seconds) 
Calling Party Disconnect Timer (1 + 12 minutes) 
Dictation Trunk 
Ignore Remote Disconnect 
Disconnect Timer (100 -+ 9900 ms) (100 ms increments) 
Supervision...

Page 177

CDE Form Descriptions 
Table 4-7 Trunk Options (continued) 
Tl DID/TIE and Ti TIE DISA 
Reverse to Idle 
Far-End Gives Answer Supervision 
Inhibit Automatic Supervision 
No Seize Alarm 
No Release Alarm 
Toll Office 
Is this a CO 
DTMF 
Save Busy-Out Status 
Disconnect Timer (I 50 -+ 300 ms) (50 ms inc) 
Release Acknowledge Timer (2 + 120 s) 
Guard Timer (200 + 1000 ms) (100 ms inc) 
Incoming Start Type (lmmed, Wink or Delay) 
Debounce Timer (20 + 150 ms) (10 ms inc) 
Wink Timer (150 + 300 ms) (50 ms...

Page 178

Customer Data Entry 
4-68 
Table 4-7 Trunk Options (continued) 
Tl LS/GS TRUNK and Tl CO DISA 
No Seize Alarm 
No Release Alarm 
Toll Office 
Is this a CO 
DTMF 
Save Busy-Out Status 
Loop Start or Ground Start (Tl LS, Tl GS) 
Calling Party Disconnect Timer (1 + 12 minutes) 
Disconnect Timer 100 + 9900 ms (100 ms inc) 
Guard Timer (0 + 3000 ms) (100 ms inc) 
Ring Cycle Timer (6 + 10 s) 
Ringing Expected 
Ringing Debounce Timer (5 + 12 seconds) 
Seize Timer (10 + 60 s) (10 s increments) 
Flash Timer (200...

Page 179

CDE Form Descriptions 
Flash Type: Specifies whether the flash will be done by opening the current loop (Loop 
Flash) or grounding the ring (Ring Ground). 
Guard Timer: This defines how long the system will wait after releasing the trunk 
before seizing it again for an outgoing call. 
Ignore Line Reversal During Seizure: If selected, line reversal is not recognized as 
an incoming seizure. 
Ignore Remote Disconnect: If selected, release signals from the far-end are ignored. 
If not selected, release...

Page 180

Customer Data Entry 
Remote End is a Satellite: Select if the trunk is to terminate at a satellite PABX. Refer 
to the Engineering hformhon /+actice for details of loss/gain. 
Remote End is a Satellite with OPS Lines: Select if the trunk is to terminate at a 
satellite PABX with OPS lines. Refer to the Engineering hforrrmtion practice for details 
of loss/gain. 
Reverse to Idle: In some central offices, upon seizure, the CO reverses the polarity 
on the trunk. When the call ends, the CO again reverses...