    							Modem interconnect Panel
    CONTENTSPAGE
    1. INTRODUCTION
    General. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
    Reason for Issue . . . . . . . . . . . . . . . . . . . . . . , . . . . . . . . . . . . . . . 1
    2. MODEM INTERCONNECT PANEL
    General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
    Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
    LIST OF TABLES
    2-lModem Interconnect Panel Connections . . . . . . . . . . . . 3
    LIST OF CHARTS
    CHART
    Tl.TLE
    2-linstall a Modem Interconnect Panel into a
    Datacabinet 9000 . . . . . . . . , . . . . . . , . . . . . . . . . . . . 5
    FIGURETITLEPAGE
    2-1Modem interconnect Panel Connectors.............4
    2-2Installation of Cardfile Rail.......................6
    PAGELIST OF ILLUSTRATIONS
    . . .III 
    						
    							Modem Interconnect Panel
    1. INTRODUCTIONGeneral
    1 .OlThis Section describes the MITEL Modem Interconnect Panel,
    part number 
    9141-940-100-NA. THE MITEL Modem Interconnect
    Panel is designed and approved only for installation in the 
    Mite1DATACABINET 9000.
    Reason for Issue
    1.02This Section is issued to describe the Modem Interconnect
    Panel.
    Page 1 
    						
    							SECTION MITL9141-753-528-NAPage 2 
    						
    							Modem Interconnect Panel
    2. MODEM INTERCONNECT PANEL
    General2.01The Modem Interconnect Panel provides a method to connect a
    voice tip-ring pair from the PABX to a modem, and to connect
    the 
    MI/MIC leads from the data set to the modem. Sixteen circuits are
    provided; each is the same, except for the tip-ring connection to the
    25-pair cable. Figure 2-1 shows the connections to a Modem Inter-
    connect Panel.
    Connections
    2.02The Teledapt jacks (FROM MODEM and TO 
    DATASET) are con-
    nected together in pairs (pin 2 to pin 2 and pin 5 to pin 5). The
    FROM MODEM Teledapt connector voice tip (pin 3) and voice ring (pin
    4) are connected to the 25-pair cable connector pins as listed in Table
    2-1. These cable pairs are then connected to ONS ports on the PABX.
    TABLE2-1
    MODEM INTERCONNECT PANEL CONNECTIONS
    DATASET Jack/25-pairConnector
    Modem Jack pairtipring
    161641
    151540
    141439
    131338
    12.I237
    111136
    10IO35
    9934
    8833
    7732
    6631
    5530
    4
    429
    3328
    2227
    1126
    Page 3 
    						
    							SECTION MITL9141-753-528-NA
    3C
    KA0346ElROFigure 2-l Modem Interconnect Panel Connectors
    Page 4 
    						
    							Modem Interconnect Panel
    CHART 2-l
    INSTALL A MODEM INTERCONNECT PANEL INTO A DATACABINET 9000
    CAUTION: Only MITEL designed and approved equipment may
    installed within a DATACABINET 9000.
    StepAction
    1.Unpack and inspect the Modem Interconnect Panel for damage or missing items.
    2.Turn off the power switch and remove the line cord from its outlet. Open the
    doors of the cabinet.
    3.
    4.
    5.install the cardfile rails for the Modem Interconnect Panel immediately above an
    existing DATASHELF 9100 or Modem Interconnect Panel. Refer to Figure 2-2. The
    Modem Interconnect Panel(s) must always be installed immediately above the
    DATASHELF 9100 to maintain correct cooling air flow.
    Place the Modem Interconnect Panel onto the 
    cardfile rails and fasten to the front
    cabinet side rails with the screws provided.
    Run the cable groups through the cable entry slots. Form each cable bundle neatly
    up the right side rail, and attach securely to the brackets on the side rails; also
    attach to the strain reliefs at the back of the Modem Interconnect Panel.
    6.Install 25-pair cables in through one of the cable entry slots on the rear PDU panel
    and route up the left side of the cabinet and attach to side rail brackets separately
    from ac cords.
    7.
    8.
    9.
    10.Close up the covers of the cable access slots.
    Connect the 25-pair cables to their associated MDF, and cross-connect the MDF
    blocks as required.
    Attach one end of a 4-wire line cord to the jack usually labeled “TELCO” on the
    rear of the modem. Attach the other end of the line cord to the Teledapt jack
    labeled “FROM MODEM” on the Modem Interconnect Panel.
    Attach one end of a 4-wire line cord to the “PHONE” jack of the Rack Mounted
    DATASET. Attach the other end of the line cord to the Teledapt jack labeled “TO
    DATASET” on the Modem Interconnect Panel.
    11.Complete the PABX Customer Data Entry for the Modem Interconnect Panel.
    12.Close and lock Cabinet doors.
    13.Connect the power cord from the DATACABINET 9000 to its ac outlet.
    bePage 5 
    						
    							CABINET ---e---vSIDE RAIL
    CARDFILE RAILIFAN UNIT SECTION 
    MITL9141-753-528-NA
    KAO601 EOR0Figure 2-2 Installation of 
    Cardfile Rail