    							Datacabinet 9000
    4. DATACABINET 9000 INSTALLATION AND WIRING
    General4.01Unpack the DATACABINET 9000 and check it for dama,ge or
    missing items. Position the cabinet where it is to be installed
    and equipped. install the shelves and cables within the cabinet accord-
    ing to Chart 4-1.
    Notes:1. Each card slot not equipped with a 
    DATASET set must be
    equipped with a filler plate to maintain correct flow of
    cooling air within the shelves; this does not apply to the
    top shelf of any configuration.
    2. Only 
    MITEL designed and approved equipment may be in-
    stalled within a DATACABINET 9000.
    CHART 4-l
    INSTALL SHELVES, CABLES, AND OTHER ASSEMBLIES INTO A DATACABINET 9000
    StepAction
    1Unpack and inspect the shelf for damage or missing items.
    2Turn off the power switch and remove the line cord from its outlet. Open the doors
    of the cabinet.
    3Install the cardfile rails in the bottom of the cabinet, above the fan unit, as shown in
    Figure 4-1, for the first shelf being installed in the cabinet, or immediately above an
    existing shelf.
    4Place the shelf onto the 
    cardfile rails and fasten to the front cabinet side rails with
    the screws provided.
    5Connect the frame ground wire from the shelf ground stud to the left side rail (as
    viewed from rear) within the cabinet, as shown in Figure 4-2. The Modem
    Interconnect Panel does not require a ground wire.
    6install remaining shelves (or Modem Interconnect Panel) similarly; each requires tha
    a pair of 
    cardfile rails be installed first.
    7Connect ac cords from distribution panel to each shelf and attach to left side rail
    within cabinet.
    8At the front of cabinet, unpack and install the DATASETs into their assigned slots.
    9Install remaining signal cables to each shelf; run the cable group for the bottom
    shelf through the right hand cable entry slot, run the cables for the middle shelf
    through the middle slot, and run the cables for the top shelf through the left slot.
    Page 9 
    						
    							SECTION MITL9141-753-525-NACHART 4-l (CONT’D)
    INSTALL SHELVES, CABLES, AND OTHER ASSEMBLIES INTO A 
    DATACABINET 9000
    StepAction
    10Form each cable bundle neatly up the right side rail, as shown in Figure 2-2, and
    attach securely to the brackets on the side rails.
    11Install 25-pair cables in through one of the three cable entry slots on the rear PDU
    panel and route up the left side of the cabinet to the associated shelves; attach to
    side rail brackets separately from ac cords.
    12
    13
    14Close up the covers of the cable access slots, close and lock rear door.
    Connect the power cord from the DATACABINET 9000 to its ac outlet.
    Connect the 25-pair cables to their associated MDF, and cross connect the MDF
    blocks as required.
    15
    16Connect the remaining signal cables to their associated equipment.
    Customer Data Entry for the DATASETs must be completed at the PABX before the
    DATASETs will operate, (refer to Section MITL9109-095-210-NA, Customer Data
    Entry).
    17Turn on the power switch on the PDU panel at the rear of the cabinet,
    18Turn on shelf power supply, and close and lock door.
    Page 10 
    						
    							Datacabinet 9000CARDFILE RAIL
    I
    FAN UNIT
    KAO601 ROE0Figure 4-l Installation of 
    Cardfile Rail
    Page 11 
    						
    							SECTION MITL9141-753-525-NAATASHELF 
    9100 i
    )ATACABINET 9001;lDE RAIL
    GROUNDWIRE
    CARDFILIRAILi
    7
    !J
    -
    a
    a
    a-
    00
    0
    0
    ]-
    i-
    -
    Ii
    T
    0
    I
    8
    0
    0--+
    0
    00
    0
    0
    0
    00
    0
    0Figure 4-2 Connection of Shelf Ground Wire
    Page 
    12 
    						
    							MITEL STANDARD PRACTICESECTION MITL9141-753-526-NAIssue 3, April 1988
    DATASHELF 9 100
    @Copyright 1988, MITEL Corporation. All rights reserved.
    T”Trademark of MITEL Corporation
    @Registered Trademark of MITEL Corporation 
    						
    							SECTION MITL9141-753-526-NAWARNING
    THIS EQUIPMENT GENERATES, USES, AND CAN RADIATE RADIO FREQUENCY ENERGY AND, IF
    NOT INSTALLED AND USED IN ACCORDANCE WITH THE INSTRUCTIONS MANUAL, MAY CAUSE
    INTERFERENCE TO RADIO COMMUNICATIONS. IT HAS BEEN TESTED AND FOUND TO COMPLY
    WITH THE LIMITS FOR A CLASS A COMPUTING DEVICE PURSUANT TO SUBPART J OF PART 15
    OF FCC RULES, WHICH ARE DESIGNED TO PROVIDE REASONABLE PROTECTION AGAINST
    SUCH INTERFERENCE WHEN OPERATED IN A COMMERCIAL ENVIRONMENT. OPERATION OF
    THIS EQUIPMENT IN A RESIDENTIAL AREA IS LIKELY TO CAUSE INTERFERENCE, IN WHICH
    CASE THE USER, AT HIS OWN EXPENSE, WILL BE REQUIRED TO TAKE WHATEVER MEASURES
    MAY BE REQUIRED TO CORRECT THE INTERFERENCE.
    NOTICE
    The information contained in this document is believed to be accurate in all respects but is
    not warranted by 
    Mite1 Corporation (MITEL). The information is subject to change without
    notice and should not be construed in any way as a commitment by 
    Mite1 or any of its
    affiliates or subsidiaries. 
    Mite1 and its affiliates and subsidiaries assume no responsibility
    for any errors or omissions in this document. Revisions of this document or new editions of
    it may be issued to incorporate such changes.
    WARNING
    THE DATASHELF 9100 IS MARKETED AND SOLD BY MITEL AS AN INTEGRAL PART OF ITS
    DATACABINET 9000 SYSTEM AND IS NOT INTENDED BY MITEL TO BE USED AT ANY TIME BY
    ANY CUSTOMER, IN WHOLE OR IN PART, IN ANY APPLICATION OTHER THAN IN AN APPRO-
    PRIATE DATACABINET 9000 SYSTEM. IN THE EVENT A DATASHELF 9100 DEVICE IS INSTALLED
    AND/OR OPERATED OTHER THAN IN AN APPROPRIATE DATACABINET 9000 SYSTEM, MITEL
    SHALL NOT BE RESPONSIBLE FOR ANY FINES, PENALTIES, CLAIMS, DAMAGES, LOSSES OR
    OTHER LIABILITIES WHICH MAY ARISE DIRECTLY OR INDIRECTLY AS A RESULT OF SUCH
    UNAUTHORIZED AND UNINTENDED USE, INCLUDING WITHOUT LIMITATION FINES OR PENAL-
    TIES FOR VIOLATION OR CONTRAVENTION OF ANY DECISIONS, ORDERS, RULES, REGULA-
    TIONS, STANDARDS OR OTHER REQUIREMENTS OF THE UNITED STATES FEDERAL COMMU-
    NICATIONS COMMISSION, UNDERWRITERS’ LABORATORIES INC. AND THE CANADIAN STAN-
    DARDS ASSOCIATION AS MAY BE IN EFFECT FROM TIME TO TIME. 
    						
    							Datashelf 9100
    1. INTRODUCTIONCONTENTSPAGE
    General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
    Reason for issue . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . , . . . . . . . 1
    2. DATASHELF 9100
    General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
    3. DATASHELF 9100 INSTALLATION AND WIRING . . . . . . , . . . . . . . . . . . . . . 7
    FIGURE
    2-l
    2-2
    3-1
    3-2
    TABLE
    2-l
    CHART
    3-lLIST OF ILLUSTRATIONS
    TITLEPAGE
    Front View of the DATASHELF 9100 . . . . . . . . . . . . . . . . 4
    Backplane and Connectors of the DATASHELF 9100 . . . . 5
    installation of Cardfile Rail . . . . . . . . . . . . . . . . . . . . . . . 8
    Connection of Shelf Ground Wire . . , . . . . . , . . . . . . . . 9
    LIST OF TABLES
    TITLEPAGE
    DATASHELF 9100 Tip and Ring Fin Assignments . . . . . . 3
    LIST OF CHARTS
    TITLEPAGE
    Install a DATASHELF 9100 into a DATACABINET 9000 . . . 7 
    						
    							SECTION MITL9141-753-526-NA
    iv 
    						
    							Datashelf 9100
    1. INTRODUCTION
    General1.01This Section describes the MITEL DATASHELF 9100, part number
    9141-901-IOO-NA. The DATASETs which mount in this shelf are
    described in separate practices.
    Reason for Issue
    1.02 This Section is issued to describe the DATASHELF 9100 in
    which 
    MITEL rack mounted DATASETs are installed.
    Page 1 
    						