Datacabinet 9000 4. DATACABINET 9000 INSTALLATION AND WIRING General4.01Unpack the DATACABINET 9000 and check it for dama,ge or missing items. Position the cabinet where it is to be installed and equipped. install the shelves and cables within the cabinet accord- ing to Chart 4-1. Notes:1. Each card slot not equipped with a DATASET set must be equipped with a filler plate to maintain correct flow of cooling air within the shelves; this does not apply to the top shelf of any configuration. 2. Only MITEL designed and approved equipment may be in- stalled within a DATACABINET 9000. CHART 4-l INSTALL SHELVES, CABLES, AND OTHER ASSEMBLIES INTO A DATACABINET 9000 StepAction 1Unpack and inspect the shelf for damage or missing items. 2Turn off the power switch and remove the line cord from its outlet. Open the doors of the cabinet. 3Install the cardfile rails in the bottom of the cabinet, above the fan unit, as shown in Figure 4-1, for the first shelf being installed in the cabinet, or immediately above an existing shelf. 4Place the shelf onto the cardfile rails and fasten to the front cabinet side rails with the screws provided. 5Connect the frame ground wire from the shelf ground stud to the left side rail (as viewed from rear) within the cabinet, as shown in Figure 4-2. The Modem Interconnect Panel does not require a ground wire. 6install remaining shelves (or Modem Interconnect Panel) similarly; each requires tha a pair of cardfile rails be installed first. 7Connect ac cords from distribution panel to each shelf and attach to left side rail within cabinet. 8At the front of cabinet, unpack and install the DATASETs into their assigned slots. 9Install remaining signal cables to each shelf; run the cable group for the bottom shelf through the right hand cable entry slot, run the cables for the middle shelf through the middle slot, and run the cables for the top shelf through the left slot. Page 9
SECTION MITL9141-753-525-NACHART 4-l (CONT’D) INSTALL SHELVES, CABLES, AND OTHER ASSEMBLIES INTO A DATACABINET 9000 StepAction 10Form each cable bundle neatly up the right side rail, as shown in Figure 2-2, and attach securely to the brackets on the side rails. 11Install 25-pair cables in through one of the three cable entry slots on the rear PDU panel and route up the left side of the cabinet to the associated shelves; attach to side rail brackets separately from ac cords. 12 13 14Close up the covers of the cable access slots, close and lock rear door. Connect the power cord from the DATACABINET 9000 to its ac outlet. Connect the 25-pair cables to their associated MDF, and cross connect the MDF blocks as required. 15 16Connect the remaining signal cables to their associated equipment. Customer Data Entry for the DATASETs must be completed at the PABX before the DATASETs will operate, (refer to Section MITL9109-095-210-NA, Customer Data Entry). 17Turn on the power switch on the PDU panel at the rear of the cabinet, 18Turn on shelf power supply, and close and lock door. Page 10
Datacabinet 9000CARDFILE RAIL I FAN UNIT KAO601 ROE0Figure 4-l Installation of Cardfile Rail Page 11
SECTION MITL9141-753-525-NAATASHELF 9100 i )ATACABINET 9001;lDE RAIL GROUNDWIRE CARDFILIRAILi 7 !J - a a a- 00 0 0 ]- i- - Ii T 0 I 8 0 0--+ 0 00 0 0 0 00 0 0Figure 4-2 Connection of Shelf Ground Wire Page 12
MITEL STANDARD PRACTICESECTION MITL9141-753-526-NAIssue 3, April 1988 DATASHELF 9 100 @Copyright 1988, MITEL Corporation. All rights reserved. T”Trademark of MITEL Corporation @Registered Trademark of MITEL Corporation
SECTION MITL9141-753-526-NAWARNING THIS EQUIPMENT GENERATES, USES, AND CAN RADIATE RADIO FREQUENCY ENERGY AND, IF NOT INSTALLED AND USED IN ACCORDANCE WITH THE INSTRUCTIONS MANUAL, MAY CAUSE INTERFERENCE TO RADIO COMMUNICATIONS. IT HAS BEEN TESTED AND FOUND TO COMPLY WITH THE LIMITS FOR A CLASS A COMPUTING DEVICE PURSUANT TO SUBPART J OF PART 15 OF FCC RULES, WHICH ARE DESIGNED TO PROVIDE REASONABLE PROTECTION AGAINST SUCH INTERFERENCE WHEN OPERATED IN A COMMERCIAL ENVIRONMENT. OPERATION OF THIS EQUIPMENT IN A RESIDENTIAL AREA IS LIKELY TO CAUSE INTERFERENCE, IN WHICH CASE THE USER, AT HIS OWN EXPENSE, WILL BE REQUIRED TO TAKE WHATEVER MEASURES MAY BE REQUIRED TO CORRECT THE INTERFERENCE. NOTICE The information contained in this document is believed to be accurate in all respects but is not warranted by Mite1 Corporation (MITEL). The information is subject to change without notice and should not be construed in any way as a commitment by Mite1 or any of its affiliates or subsidiaries. Mite1 and its affiliates and subsidiaries assume no responsibility for any errors or omissions in this document. Revisions of this document or new editions of it may be issued to incorporate such changes. WARNING THE DATASHELF 9100 IS MARKETED AND SOLD BY MITEL AS AN INTEGRAL PART OF ITS DATACABINET 9000 SYSTEM AND IS NOT INTENDED BY MITEL TO BE USED AT ANY TIME BY ANY CUSTOMER, IN WHOLE OR IN PART, IN ANY APPLICATION OTHER THAN IN AN APPRO- PRIATE DATACABINET 9000 SYSTEM. IN THE EVENT A DATASHELF 9100 DEVICE IS INSTALLED AND/OR OPERATED OTHER THAN IN AN APPROPRIATE DATACABINET 9000 SYSTEM, MITEL SHALL NOT BE RESPONSIBLE FOR ANY FINES, PENALTIES, CLAIMS, DAMAGES, LOSSES OR OTHER LIABILITIES WHICH MAY ARISE DIRECTLY OR INDIRECTLY AS A RESULT OF SUCH UNAUTHORIZED AND UNINTENDED USE, INCLUDING WITHOUT LIMITATION FINES OR PENAL- TIES FOR VIOLATION OR CONTRAVENTION OF ANY DECISIONS, ORDERS, RULES, REGULA- TIONS, STANDARDS OR OTHER REQUIREMENTS OF THE UNITED STATES FEDERAL COMMU- NICATIONS COMMISSION, UNDERWRITERS’ LABORATORIES INC. AND THE CANADIAN STAN- DARDS ASSOCIATION AS MAY BE IN EFFECT FROM TIME TO TIME.
Datashelf 9100 1. INTRODUCTIONCONTENTSPAGE General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Reason for issue . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . , . . . . . . . 1 2. DATASHELF 9100 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 3. DATASHELF 9100 INSTALLATION AND WIRING . . . . . . , . . . . . . . . . . . . . . 7 FIGURE 2-l 2-2 3-1 3-2 TABLE 2-l CHART 3-lLIST OF ILLUSTRATIONS TITLEPAGE Front View of the DATASHELF 9100 . . . . . . . . . . . . . . . . 4 Backplane and Connectors of the DATASHELF 9100 . . . . 5 installation of Cardfile Rail . . . . . . . . . . . . . . . . . . . . . . . 8 Connection of Shelf Ground Wire . . , . . . . . , . . . . . . . . 9 LIST OF TABLES TITLEPAGE DATASHELF 9100 Tip and Ring Fin Assignments . . . . . . 3 LIST OF CHARTS TITLEPAGE Install a DATASHELF 9100 into a DATACABINET 9000 . . . 7
Datashelf 9100 1. INTRODUCTION General1.01This Section describes the MITEL DATASHELF 9100, part number 9141-901-IOO-NA. The DATASETs which mount in this shelf are described in separate practices. Reason for Issue 1.02 This Section is issued to describe the DATASHELF 9100 in which MITEL rack mounted DATASETs are installed. Page 1