Datashelf 9100 2. DATASHELF 9100 General2.01The DATASHELF 9100 is 8.75 in. high. The left side of the shelf holds up to 16 DATASETs, while the right side contains an integral shelf power supply. All connections to the DATASHELF 9100 are made at the back of the shelf. Each card has connectors which are connected directly to the device with which the DATASET is to cbm-municate. Each DATASET also has an edge connector which plugs into the shelf backplane; this connector provides power to the card, and connects to the backplane connector which connects tip-ring pair to the PABX. Figure 2-l shows a front view of the DATASHELF 9100. 2.02The shelf power supply, the shelf, and the backplane are one integral unit. The power supply provides 9 vat to each card connector. A 25-pair connector on the backplane connects the tip-ring pairs from the DATASETs to the PABX. The power cord from the ac distribution panel plugs into the back of the shelf, directly behind the power supply. Figure 2-2 shows the backplane and connectors of the DATASHELF 9100. 2.03The DATASET edge connectors which plug into the shelf con- nect the tip and ring to the 25-pair connector which is cabled to the PABX MDF. The pair assigned to each DATASET is listed in Table 2-1. TABLE 2-l DATASHELF 9100 TIP AND RING PIN ASSIGNMENTS slot DATASETtipringJ17 connector tipring Jl112261J2 112272 J3 112283 J4 112294 J5 112305J6 112316 J7 112327 J8 112338 J9112 934 JIO112 1035 Jll1121136 J12 1121237 J13112 1338 J14 1121439 J15 112 1540 J16 112 1641Page 3
SECTION MITL9141-753-526-NARACK-MOUNTED DATASET CARDON/OFF SWITCH POWER SUPPLV KAo317m IFigure 2-l Front View of the DATASHELF 9100 Page 4
Datashelf 9100IWMARVINIPUT FUSE GROUND/ STUD POWER CORDCONNECTOR \ KA0344RZEFigure 2-2 Backplane and Connectors of the DATASHELF 9100 Page 5
Datashelf 9100 3. DATASHELF 9100 INSTALLATION AND WIRING Note:Each card slot not equipped with a DATASET set must be equipped with a filler plate to maintain correct flow of cooling air within the shelves; this does not apply to the top shelf of any configuration. CHART 3-1 INSTALL DATASHELF 9100 INTO A DATACABINET 9000 StepAction 1Unpack and inspect the shelf for damage or missing items. 2Turn off the DATACABINET 9000 power switch and remove the line cord from its outlet. Open the doors of the cabinet. 3Install the cardfile rails in the bottom of the cabinet, above the fan unit, as shown in Figure 3-1, for the first shelf being installed in the cabinet, or immediately above an existing shelf. 4Place the shelf onto the cardfile rails and fasten to the front cabinet side rails with the screws provided. 5Connect the frame ground wire from the shelf ground stud to the left side rail (as viewed from rear) within the cabinet, as shown in Figure 3-2. 6Connect ac cords from distribution panel to the shelf and attach to left side rail within cabinet. 7Unpack and install DATASETs into their assigned slots. 8Install signal cables to each shelf, and connect the signal cables to their associated equipment. 9Form a cable bundle neatly up the right side rail, and attach securely to the brackets on the side rails. 10 11 12 13Install 25-pair cable to the shelf; attach to side rail brackets separately from ac cords. Connect the 25-pair cable to its associated MDF, and cross connect the MDF blocks as required. Close up the covers of the cable access slots, close and lock rear door. Connect the power cord from the DATACABINET 9000 to its ac outlet. Customer Data Entry for the DATASETs must be completed at the PABX before the DATASETs will operate (refer to PABX Customer Data Entry Practice). 14Turn on the power switch on the PDU panel at the rear of the cabinet. 15Turn on shelf power supply, and close and lock door. Page 7
SECTION MITL9141-753-526-NA CARDFILE RAIL I FAN UNIT KAO60 1 ROE0Figure 3-l Installation of Cardfile Rail Page 8
Datashelf 9100l!L 0DATASHELF 9100 80 0DATACABINET 9000 SIDE RAIL - CARDFILE RAILII“I III0 0 0 0 0 r 0 Q0 0 III/f--L- I:: . . Figure 3-2 Connection of Shelf Ground Wire Page 9
MITEL STANDARD PRACTICESECTION MITL9141-753-528-NAIssue 1, April 1988 MODEM INTERCONNECT PANEL @Copyright 1988, MITEL Corporation. All rights reserved. T”Trademark of MITEL Corporation @Registered Trademark of MITEL Corporationi
SECTION MITL9141-753-528-NANOTICE The information contained in this document is believed to be accurate in all respects but is not warranted by Mite1 Corporation (MITEL). The information is subject to change without notice and should not be construed in any way as a commitment by Mite1 or any of its affiliates or subsidiaries. Mite1 and its affiliates and subsidiaries assume no responsibility for any errors or omissions in this document. Revisions of this document or new editions of it may be issued to incorporate such changes.