Home > Mitel > Communications System > Mitel SX 200 DIGITAL Pabx Superset 3 Telephone Description Manual

Mitel SX 200 DIGITAL Pabx Superset 3 Telephone Description Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Mitel SX 200 DIGITAL Pabx Superset 3 Telephone Description Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 55 Mitel manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							MITL9109-094-109-NAPage 20 
    						
    							SUPERSET 4DN Telephone information
    8. PACKAGING
    General
    8.01The SUPERSEJ 4DN telephone is shipped in a single carton.
    8.02On delivery at the destination, carefully unpack the SUPERSEJ
    4DN telephone carton and check that all items are present and
    undamaged.’ Retain some packaging for reshipment of any damaged
    items.
    8.03 The SUPERSEJ 4DN telephone consists of a main assembly,
    handset, and handset cord. Additional items include identifica-
    tion cards (for telephone numbers and lines), protective covers for
    these cards, reference guide, installation guide, and warranty tag.
    Page 
    21 
    						
    							MITL9109-094-109-NAPage 22 
    						
    							SUPERSET 4DN Telephone Information
    9. INSTALLATION AND MAINTENANCE
    WARNING
    ANY CONNECTION OF THIS SET TO AN OFF PREMISE APPLICATION,
    AN OUT OF PLANT APPLICATION, OR TO ANY OTHER EXPOSED
    PLANT APPLICATION MAY RESULT IN A SAFETY HAZARD, AND/OR
    DEFECTIVE OPERATION, AND/OR EQUIPMENT DAMAGE.
    9.01Installers should not attempt to use a hand test telephone (butt
    in) to check 
    SUPERSET 4DN telephone lines, because there is no
    loop detector installed in the PABX Digital Line Card: set on-/off-hook
    status is signaled using data transmission. 
    SUPERSET 4DN telephones
    must not be connected to standard lines, in parallel, or as Power Fail
    Transfer extensions.
    Installation
    9.02Installation of a 
    SUPERSET 4DN telephone is simplified because
    of the following:
    lHandset and line cords are modular-connector-ended.
    aNo local power supply is required; the system provides power
    through the line.
    0Only nonessential user programming is performed at the set;
    speed dial entry, call forward destination, name, and timed re-
    minder.
    0Installer can use set display feature to identify lines pro-
    grammed to appear at the set.
    0Initialization of the SUPERSET 4DN telephone occurs automati-
    cally when the set is connected to the system and pro-
    grammed. It takes 20-30 seconds; during part of the initializa-
    tion procedure, WAITING FOR COMMUNICATION is displayed.
    Upon completion, time and date are displayed.
    9.03Install a 
    SUPERSET 4DN telephone as follows:
    lBefore a SUPERSET 4DN telephone can be connected to a PABX
    system, the PABX must be programmed and equipped with a
    Digital Line Card to interface with it.
    lConnect the handset cord to the handset and the main assem-
    bly.
    0Install the card and protective lens onto the main assembly.
    0Identify the user’s telephone number, extension number, and
    other line appearances at the 
    SUPERSET 4DN telephone on the
    line identification card.
    Page 23 
    						
    							MITL9109-094-109-NA
    ainstall the line identification card and protective cover onto the
    main assembly.
    0Connect the line cord to the telephone jack (which has been
    connected to the Digital Line Card within the PABX).
    Environmental Specifications
    Operating Environment:
    Ambient Temperature: 4 to 49°C (39.2 to 120°F).
    Ambient Humidity: 10 to 90% RH, noncondensing.
    Storage/Shipping Environment:
    Ambient Temperature: -40 to 60°C (-40 to 150°F).
    Ambient Humidity: 
    IO to 90% RH, noncondensing.
    Page 24 
    						
    							MITEL STANDARD PRACTICESECTION MITLSI 09-094-125-NAIssue 1, March 1988
    SX-200” DIGITAL
    PRIVATE AUTOMATIC BRANCH EXCHANGE (PABX)
    CIRCUIT CARD DESCRIPTIONS
    @Copyright 1988, MITEL Corporation. All rights reserved,
    T”Trademark of MITEL Corporation
    @Registered Trademark of MITEL Corporation 
    						
    							SECTION MITL9109-094-125-NANOTICE
    The information contained in this document is believed to be accurate in all respects but is
    not warranted by 
    Mite1 Corporation (MITEL). The information is subject to change without
    notice and should not be construed in any way as a commitment by 
    Mite1 or any of its
    affiliates or subsidiaries. 
    Mite1 and its affiliates and subsidiaries assume no responsibility
    for any errors or omissions in this document. Revisions of this document or new editions of
    it may be issued to incorporate such changes. 
    						
    							Circuit Card Descriptions
    CONTENTSPAGE1. INTRODUCTION
    General . . . . . . . . . . . . . . . . . . . . . . . , . . . . . . . . . . . . . . . . . . . . , 1
    Reason for Issue . . . . . . . . . . . . . . . . . . . . . . . . . . , . . . . . . . . . . , 1
    2. MAIN CONTROL CARD
    Description..........................................
    3Facilities............................................
    3Operation............................................
    43. DECRYPTION MODULE
    Brief Description. . . . . . . . . . . . . . , . . . . . . . . . . . . . . . . . . . . . . . 7
    Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
    4. RAM MODULE
    Brief Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
    5. DX MODULE
    Brief Description.....................................
    11Facilities...........................................
    11Electrical Description..................................
    116. 
    Tl CLOCK MODULE
    Brief Description.....................................
    13Electrical Description..................................
    13Physical Description...................................
    137. BAY CONTROL CARD
    General............................................
    15Functions...........................................
    15Indicators...........................................
    15Electrical Description..................................
    ‘I 58. PERIPHERAL CONTROL CARD
    Brief Description.....................................
    17Major Components....................................
    17Facilities...........................................
    179. DIGITAL INTERFACE CARD
    Brief Description.....................................
    19Facilities...........................................
    19Connections.........................................
    1910. UNIVERSAL CARD
    Brief Description.....................................
    21Facilities............................................
    21Physical Description...................................
    21Electrical Description..................................
    2111. CONSOLE MODULE
    Brief Description. . . . . . . . . . . , . . . . . . . . . . . . . . . . . . . . . . . . . 25
    Electrical Description . . . . , . . . . . . . . . . , . . . . , . . . , . . . . . . . . . 25
    . . .III 
    						
    							SECTION MITL9109-094-q 25-NA
    CONTENTS (CONT’D)
    12. DTMF RECEIVER/RELAY MODULE
    Brief Description.....................................27
    Main Components....................................27
    Facilities...........................................
    27
    Circuit Description....................................27
    Relays.............................................28
    13. E&M TRUNK MODULE
    Brief Description.....................................29
    Facilities...........................................29
    Operation...........................................29
    TrunkTypes.........................................30
    14. MUSIC ON HOLD/PAGING MODULE
    Brief Description.....................................
    31Major Components....................................
    31Electrical Description..................................
    3115. DID TRUNK CARD
    Brief Description.....................................
    33
    Major Components....................................33
    Facilities...........................................33
    Operation...........................................33
    Electrical Description..................................34
    16. 
    LWGS TRUNK CARD
    Brief Description.....
    ;...............................35
    Facilities...........................................35
    Electrical Description..................................35
    Operation
    - Loop Start..................................35
    Operation
    - Ground Start...............................37
    17. ONS LINE CARD
    General Description...................................39
    Facilities...........................................
    39
    Electrical Description..................................39
    Operation
    ...........................................40
    18. OPS LINE CARD
    Brief Description......................................
    41Major Components....................................
    41Facilities...........................................
    41Operation...........................................
    41Electrical Description..................................42
    19. COV LINE CARD
    General...................................
    .,........43
    Major Components....................................43
    Facilities...........................................43
    Electrical Description..................................44
    iv 
    						
    							Circuit Card Descriptions
    CONTENTS (CONT’D)PAGE20. DIGITAL LINE CARD
    General Description
    ...................................45
    Facilities
    ...........................................45
    Electrical Description
    ..................................45
    DNIC Description
    .....................................46
    Operation
    ...........................................46
    21. POWER FAIL TRANSFER CARD (6 CIRCUIT)
    Brief Description
    .....................................47
    Connections.........................................
    47
    Electrical Description
    ..................................47
    Operation...........................................
    48
    22. SWITCH MATRIX CARD
    Facilities
    ............................................
    51DXArray...........................................51Ringing Reference Generator
    ............................
    51Non-volatile Static RAM
    ................................
    5123. 
    Tl DIGITAL TRUNK CARD
    Brief Description
    .....................................53
    Facilities
    ...........................................53
    General Description
    ....................................53
    Electrical Description
    ..................................54
    Indicators
    ...........................................54
    Physical Description
    ...................................54
    TABLE
    12-1LIST OF TABLES
    TITLE
    PAGE
    DTMF Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
    LIST OF ILLUSTRATIONS
    FIGURE
    TITLE
    PAGE
    l-lDigital Card Faces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
    2-l
    Main Control Card and Decryption Module . . . . . . . . . . . 5
    7-l
    Bay Control Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
    8-lMain Control Card and Interface Cards for Analog Shelf 18
    9-lDigital Interface Card . . . . . . . . . . . . . . . . . . . . . . . . . . 20
    IO-1Universal Card and Modules . . . . . . . . . . . . . . . . . . . . 23
    16-1Loop Start/Ground Start Card and Jumper Location . . . 36
    21-1Power Fail Transfer Card . . . . . . . . . . . . . . . . . . . . . . . 49
    V 
    						
    All Mitel manuals Comments (0)

    Related Manuals for Mitel SX 200 DIGITAL Pabx Superset 3 Telephone Description Manual