Page 161

Installation Forms 
TABLE 3-9 
FORM 08 - ATTENDANT LDN ASSIGNMENTS 
SHEET 
-OF - 
BAY/SLT/CCT: CONSOLE EXTENSION NUMBER: 
BAY/SLT/CCT: CONSOLE EXTENSION NUMBER: 
KEY DIR NUMBER LABEL 
COMMENTS 
2 
3 
4 
5 
6 
7 
8 
9 
0 
Notes: 1. There are a maximum of 11 consoles. 
2. The directory number is a maximum of five digits. It links this form to Form 19, Call 
Rerouting Table, where the actual call type is defined for each directory number. The 
directory number programmed for softkey 2 shares the softkey...

Page 162

Installation Forms 
TABLE 3-10 
FORM 09 - STATION/SUPERSET@ SETS 
SHEET -OF - 
Notes: 1. Specify the Tenant Group, Extension Number, COS number and COR number for each 
device. 
2. Specify the device type in the TYP field as a Rotary Dial or DTMF set (STN), 
SUPERSET@ set (SET) or Call Announce Port (CAP). The CAP can be a Station Circuit, a 
SUPERSET@ set circuit or COV circuit. Hardware restrictions prevent a digital ONS 
circuit from being a CAP. 
3. Specify the physical location (by the bay, slot and...

Page 163

installation Forms 
TABLE 3-11 
SUPERSET@ SET LINES 
SHEET-OF - 
BAY/SLT/CCT: 
EXTENSION NUMBER: 
Notes: 1. This form is a nested form and can only be accessed from the previous form 
(Station/SUPERSET@ Sets). 
2. Key 1 is the Prime Line and cannot be modified. 
3. For each Line Select key, select a variant for each of the following four categories: 
TYPE KEY = Key Line RING IMMED = Immediate Ring 
Multiple = Multiple Call Line DELAY = Delay Ring 
Personal = Personal Outgoing Line NO = No Ring 
DTS =...

Page 164

TABLE 3-12 
FORM 10 - PICKUP GROUPS 
SHEET 
-OF _ 
I I I I I I I 
I I 
Notes: 1. The system supports a maximum of 50 Pickup Groups and each Pickup Group supports 
a maximum of 50 members. 
2. The order in which the Pickup Group members are entered is not significant. 
3. Pickup Group members are restricted to extension numbers of Rotary Dial or DTMF 
sets or Prime Line numbers of SUPERSET@ sets. Attendant Consoles are not allowed in 
Pickup Groups. 
Page 3-20  

Page 165

Installation Forms 
TABLE 3-13 
FORM 13 - TRUNK CIRCUIT DESCRIPTORS 
SHEET 1 OF 1 
21 
22 
23 
24 
25 
Notes: 1. Specify a Trunk Type for the required trunk circuit descriptors. The Trunk Types 
include: 4-CCT CO, 4-CCT DISA, E&M CARD, E&M Module”*, 2-CCT DID/TIE, 6-CCT 
DID**, 6-CCT CO and 6-CCT DISA. 
2. The COMMENTS field stores additional information. It is not used by the system and 
can have a maximum of 20 characters. 
* Generic 1000 ** Generic 1001 
Page 3-21  

Page 166

Installation Forms 
TABLE 3-14 
TRUNK CIRCUIT DESCRIPTOR OPTIONS SHEET _ OF _ 
4-CIRCUIT CO TRUNK and TRUNK CIRCUIT DESCRIPTOR NUMBER (1 -. 25) 
4-CIRCUIT DISA OPTIONS 
Far-End Gives Answer 
Supervision (Y or N) 
Inhibit Automatic 
Supervision (Y or N) 
No Seize Alarm (Y or N) 
Complex) 
Dictation Trunk (Y or N) 
Notes: 1. This form is a nested form and can only be accessed from the previous form (Trunk 
Circuit Descriptors). 
2. Specify the hardware options for the selected trunk circuit descriptor...

Page 167

Installation Forms 
TABLE 3-14 (CONT’D) 
upervision Direction: 
* Generic 1000 ** Generic 1001 
Page 3-23  

Page 168

TABLE 3-14 (CONT’D) 
TRUNK CIRCUIT DESCRIPTOR OPTIONS 
SHEET _ OF _ 
Notes: 1. This form is a nested form 
and can only be accessed from the previous form (Trunk 
Circuit Descriptors). 
2. Specify the hardware options for the selected trunk circuit descriptor number. The 
options can be specified only after a trunk type has been assigned to a trunk circuit 
descriptor number. 
Page 3-24  

Page 169

Installation Forms 
TABLE 3-14 (CONT’D) 
TRUNK CIRCUIT DESCRIPTOR OPTIONS SHEET _ OF _ 
Toll Office (Y or N) 
Is this a CO (Y or N) 
DTMF (Y or N) 
Impedance ** Use DIP Switch on the Module 
to Program ** (600 Ohms or Complex) 
E Lead Invert (Y or N) 
M Lead Invert (Y or N) 
Disconnect Timer (150 - 300 ms) x (50 ms 
increments) 
Release Acknowledge Timer (2000 - 9900 ms) 
x (100 ms increments) 
Guard Timer (200 - 1000 ms) x (100 ms 
increments) 
Dictation Trunk (Y or N) 
Incoming Start Type (Immed, Wink...

Page 170

Installation Forms 
TABLE 3-14 (CONT’D) 
TRUNK CIRCUIT DESCRIPTOR OPTIONS SHEET _ OF _ 
E&M MODULE 
OPTIONS ** TRUNK CIRCUIT DESCRIPTOR NUMBER (1 - 25) 
Remote End is a Satellite with OPS Lines (Y 
or N) 
4-Wire (Y or N) 
4-Wire Unamplified (Y or N) 
* Generic 1000 ** Generic 1001 
Notes: 1. This form is a nested form and can only be accessed from the previous form (Trunk 
Circuit Descriptors). 
2. Specify the hardware options for the selected trunk circuit descriptor number. The 
options can be...