Home > Mitel > Communications System > Mitel SX-200 DIGITAL Pabx Information Manual

Mitel SX-200 DIGITAL Pabx Information Manual

Here you can view all the pages of manual Mitel SX-200 DIGITAL Pabx Information Manual. The Mitel manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 191

Installation Forms 
TABLE 3-29 (CONT’D) 
FORM 27 - FORM ACCESS RESTRICTION DEFINITION 
FORM NAME INST 
30 = SYSTEM DIAL ENTRY ** 
31 = CDE DATA PRINT ** 
32 = ACCOUNT CODE ENTRY ** 
* Generic 1000 ** Generic 1001 MAINTl MAINTZ SHEET 2 OF 2 
SUPER ATT 
Notes: 1. The Installer level of access defaults to a Read/Write (R/W) access for each form. All 
other levels of access default to No Access (none). 
2. The Installer level of access has the highest degree of access and cannot be modified. 
3. Specify an...

Page 192

installation Forms 
TABLE 3-30 
FORM 29 - DEVICE INTERCONNECTION TABLE ** 
cLleel- 1 nc 1 
UllLLl I “I 1 
I 
--.,,-r “;; 
, , n. n.3 n-3 I U, , “L , VJ , 
54 ( 05 I06 ( 07 ( 06 I09 
1 10 1 11 1 12 I 13 I 
14 I 15 I 16 I17 I 18 I 
19 120 I21 I22 I23 I24 
I25 1 
STATION/ 01 
SET 
I I 1 i i i 
IiiiyI 1 1 1 
G4Y&y”-1 1 1 1 1 CONSOLE 02 
LOOP 03 
START 
TRUNK 
GROUND 04 
START 
TRUNK 
DID/TIE 05 
I I I I I I I II I 
RESERVED 11 
I 
III I l l I I I I I I l / RESERVED 20 
III II I I III 1 
RESERVED 22 
RESERVED...

Page 193

Installation Forms 
TABLE 3-31 
FORM 30 - SYSTEM ABBREVIATED DIAL ENTRY ** 
SHEET _ OF _ 
NUMBER DIGIT STRING 
* Generic 1000 ** Generic 1001 
Notes: 1. Specify the Index Number; a maximum of three digits. 
2. Specify the Digit String; a maximum of 26 digits (25 if private). 
3. Specify which entries are Private (Y) or Non-Private (N). 
Page 3-49  

Page 194

installation Forms 
TABLE 3-32 
FORM 32 - ACCOUNT CODE ENTRY ** 
SHEET OF 
* Generic 1000 ** Generic 1001 
Notes: 1. 
Specify the Account Code number. The length is determined by System Option 44, 
Account Code Length (set to a fixed value from 4 to 1.2 digits or variable from 1 to 12 
digits). 
2. Specify the COS and COR numbers. This field may be left blank. 
3. indicate the accessible Account Codes with “Active” in the ACTIVE field. Specifiy those 
Account Codes which are denied access with “Inactive”...

Page 195

Installation Forms 
4. TRUNK CARD SWITCH ASSIGNMENT FORMS 
General 
4.01 
The following forms enable the installer to configure the 
switches of the system’s Trunk Cards. There are switch assign- 
ments for CO Trunk Cards, E&M/Tie Trunk Cards and DID/Tie Trunk 
Cards. These forms complement Form 13 - Trunk Circuit Descriptors 
(refer to Table 3-13, in this Section). Each form is accompanied by a 
diagram indicating the switch locations and special notes. 
Page 4-l  

Page 196

TABLE 4-l TRUNK CARD SWITCH SETTINGS - CO TRUNK CARD 
SLOT 
NO. 
SLOT 
NO. 
SLOT 
NO. 
SLOT 
NO. 
SLOT 
NO. 
co DIRECTORY 
NO. 
3TES 
BAV 
NO. 
3.4 or 5 ,NCOM,NG OUTGOING LOOP/GND 3RD WIRE SENSE RELEASE TIME 
START 
CIRCUIT THUNK CONDITION CONDITION CONDITION REVERSALS 
NUMBER NUMBER “8” SHRT “8” LONG 
(l-200) 
BUSY IDLE BUSY IDLE LOOP GND ENAB DIS IGN -A” “8” 
EFF SHRTLoNG $LT yo’kG 
33/60 
1 
4 
1 
2 
3 I I 
z 
3 
4 
1 
2 
3 
4 I 
I II II II II I III1 II 
1. EARLIER TRUNK CARD VERSIONS DO NOT HAVE ALL...

Page 197

Installation Forms 
HIGH IMPEDANCE SWITCHES 
/ OPEN  NORMAL SETTING 
GND HIGH Z 1 = OPEN 
2 = CLOSED 
(NOTE 1O)XT HIGH-Z (NOTE 11) 
TRUNK 2 TR2 TRI 
:~-iiiij -48V NORMAL 
TRUNK BUSY SWITCHES (NOTES 1 AND 2) 
NORMAL 
SETTING 
1 = OPEN 
2 = OPEN 
3 = OPEN 
4 = OPEN 
5 = CLOSED 
6 = CLOSED 
7 = CLOSED 
8 = CLOSED  OUTGOING 
IDLE 
0 B OPEN 
II 10-i 
A TRUNK CONTROL 
SWITCHES TRUNK BUL 
SWITCHES 
PROMS 
 
TRUNK 2k 
TRUNK/+ 
TRUNK4 INCOMING 
IDLE 
TRUNK 4 TR4 TR3 
@iii; 
I 1 
hd 
TRUNK CONTROL SWITCHES 
NORMAL...

Page 198

installation Forms 
NOTES FOR FIGURE 4-l 
CO TRUNK CARD SWITCH FUNCTIONS 
1. OUTGOING BUSY SWITCHES (1 PER TRUNK) CAN BE 
SET FOR EITHER: 
IDLE - NORMAL TRUNK OPERATION 
BUSY - TRUNK CANNOT BE SEIZED FOR 
OUTGOING CALL “A” SETTING “B” SElTlNG RELEASE TIME 
OPEN CLOSED 50 ms 
CLOSED CLOSED 
500 ms 
OPEN OPEN 
2.5 s 
CLOSED OPEN INFINITE 
(NON-RELEASE)  TRUNK BUSV SWITCHES 
2. THE “OUTGOING BUSY” CONDITION MAY BE SET 
EITHER BY THE OUTGOING BUSY SWITCH (NOTE I), 
OR BY THE CONSOLE “TRUNK BUSY OUT”...

Page 199

Installation Forms 
TABLE 4-2 
TRUNK CARD SWITCH SETTINGS - E&M/TIE TRUNK CARD 
TRUNK 1 
TRUNK 2 
BAV NUMBER 
SLOT NUMBER 
CIRCUIT NUMBER 
TRUNK NUMBER (l-200) 
INCOMING WINK 
Z/4 WIRE CONDITIONS 
NOT STOP DIAL r ,nv,un I 
TRUNK 2 
BAY NUMBER 
SLOT NUMBER 
31RCUIT NUMBER 
FRUNK NUMBER (l-200) 
INCOMING WINK 
SHEET _ OF _ 
. . ...*..... . 
NOTE: TRUNK CARD SWITCHES MUST BE SET TO ONE OF THE TWO POSSIBLE SETTINGS FOR EACH SWITCH AS DETAILED IN SECTION 
MITLglOB-093~ZOO-NA, SHIPPING, RECEIVING AND...

Page 200

Installation Forms 
TRUNK CONTROL SWITCHES 
/ 
OPEN 
 
SPECIAL 
,N+i% 3) NORMAL SETTING 
NOT 
OUTGOING NOT 
WINK INCOMING 
WINK Z-WIRE 
, 1 
4-WIRE 1 = CLOSED 
2 = CLOSED 
3 = OPEN 
4 = OPEN 
5 = CLOSED 
6 = CLOSED 
7 = CLOSED 
El = CLOSED 
9 = NOT USED 
10 = NOT USED 
- 
t 0 
C 
I 
- - 
PN103026 
6OOfl 
I---, TRUNK 1 
I , IMPEDANCE 
i l SWITCHES 
; (NOTE 1) 
9iiJTl 
Z-WIRE 
r-7 
I I 
I 
! -1 
4-ii’IRE 
10 BUSY 
1 
SWITCHES 
TRUNKCONTROL 
SWITCHES 
TRUNK BUSY SWITCHES 
OUTGOIN’ 
IDLE 
(NOTE 2 
NOT 
STOP...