Mitel SX-200 DIGITAL Pabx Information Manual
Here you can view all the pages of manual Mitel SX-200 DIGITAL Pabx Information Manual. The Mitel manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 171
installation Forms TABLE 3-14 (CONT’D) TRUNK CIRCUIT DESCRIPTOR OPTIONS SHEET _ OF _ E&M CARD OPTIONS Remote End is a Satellite (Y or N) Remote End is a Satellite with OPS Lines (Y or N) Dictation Trunk (Y or N) Notes: 1. This form is a nested form and can only be accessed from the previous form (Trunk Circuit Descriptors). 2. Specify the hardware options for the selected trunk circuit descriptor number. The options can be specified only after a trunk type has been assigned to a trunk...
Page 172
installation Forms TABLE 3-14 (CONT’D) TRUNK CIRCUIT DESCRIPTOR OPTIONS SHEET _ OF _ Remote End is a Satellite (Y or N) Remote End is a Satellite with OPS Lines (Y or N) Notes: 1. This form is a nested form and can only be accessed from the previous form (Trunk Circuit Descriptors). 2. Specify the hardware options for the selected trunk circuit descriptor number. The options can be specified only after a trunk type has been assigned to a trunk circuit descriptor number. Page 3-28
Page 173
Installation Forms TABLE 3-14 (CONT’D) TRUNK CIRCUIT DESCRIPTOR OPTIONS SHEET _ OF _ B-CIRCUIT DID OPTIONS ** 150 ms) x (IO ms Wink Timer (150 - 300 ms) x (50 ms increments) Remote End is a Satellite (Y or N) Remote End is a Satellite with OPS Lines (Y or N) * Generic 1000 ** Generic 1001 Notes: 1. This form is a nested form and can only be accessed from the previous form (Trunk Circuit Descriptors). 2. Specify the hardware options for the selected trunk circuit descriptor number. The...
Page 174
Installation Forms TABLE 3-15 FORM 14 - NON-DIAL-IN TRUNKS SHEET -OF - CDN 1 TK NUM 1 COMMENTS Notes: 1. Specify the COS number, Tenant Group number and the trunk number (1 4 200). 2. Specify the answer points for Day, Nightl, and Night2 Service Modes. The answer points may be specified as an LDN on the Attendant Console, a station number (or a SUPERSET@ set Prime Line number), a Hunt Group Access Code or a Night Bell equipment extension number. An LDN and Night Bell cannot be rung...
Page 175
Installation Forms TABLE 3-16 FORM 15 - DIAL-IN TRUNKS SHEET -OF - Notes: 1. 2. 3. 4. 5. 6. Specify COS number, COR number, Tenant Group number and the trunk number (1 + 200). Assign a trunk circuit descriptor number in the CDN field for each Dial-In Trunk. The CDN field links this form to Form 13, Trunk Circuit Descriptors which defines the trunk hardware parameters. Specify the number of expected digits (1 to 9) if required in the N field. Digit translation on incoming calls occurs...
Page 176
Installation Forms TABLE 3-17 FORM 16 - TRUNK GROUPS SHEET -OF - TRUNK GROUP NUMBER (1 - 50): TRUNK GROUP NAME: HUNTING (TERMINAL/CIRCULAR): SMDR (Y/N): 1 Trunk Group Function: I ~~ ~~ TRUNK NUMBERS TRUNK GROUP NUMBER (1 - 50): 1 TRUNK GROUP NAME: I Notes: ‘I. There are maximum of 50 members per Trunk Group and the system supports a maximum of 50 Trunk Groups. 2. Specify each member of the Trunk Group by trunk number. Trunk Group hunting occurs in the order that the members are entered....
Page 177
installation Forms TABLE 3-18 FORM 17 - HUNT GROUPS SHEET -OF - HUNT GROUP NUMBER (1 -, 50): ACCESS CODE: HUNTING TYPE (TERMINAL/CIRCULAR): HUNT GROUP TYPE: Hunt Group Function: EXTENSION NUMBERS HUNT GROUP NUMBER (1 - 50): HUNTING TYPE (TERMINAL/CIRCULAR): Hunt Group Function: ACCESS CODE: HUNT GROUP TYPE: Notes: 1. There are maximum of 50 members per Hunt Group and the system supports a maximum of 50 Hunt Groups. 2. Specify each member of the Hunt Group by extension number. Hunting...
Page 178
Installation Forms TABLE 3-19 FORM 18 - MISCELLANEOUS SYSTEM PORTS SHEET 1 OF 2 27 28 29 30 Night Bell 14 Night Bell 15 Night Bell 16 Night Bell 17 Page 3-34
Page 179
Installation Forms TABLE 3-19 (CONT’D) FORM 18 - MISCELLANEOUS SYSTEM PORTS SHEET 2 OF 2 Notes: 1. Specify the physical location (bay, slot, circuit and subcircuit numbers) of the miscella- neous devices. 2. Specification of the extension numbers is only required for the Night Bell relays. Night Bell definitions are restricted to Universal Card slots. 3. The subcircuit (XT) fields for the music on hold module and the nine paging zones will be filled in by the system. Page 3-35
Page 180
Installation Forms TABLE 3-20 FORM 19 - CALL REROUTING TABLE TENANT GROUP (1 - 25): SHEET -OF - I TYPE OF CALL 1 DAY 1 Nl 1 N2 Station Dial 0 Routing Prioritv Dial 0 Routing I DID Recall Points on Busy I I I DID Recall Points on No Answer DID Routing for Calls into this Tenant I DID Intercept Routing For Calls into this Tenant I I I DID Vacant Number Routing for this Tenant DID Attendant Night Access Points 1 Non-Dial-In Trunks Alternate Recall Points I I I Dial-In Tie Recall Points On...