Home > Mitel > Communications System > Mitel SX-200 DIGITAL Pabx Information Manual

Mitel SX-200 DIGITAL Pabx Information Manual

Here you can view all the pages of manual Mitel SX-200 DIGITAL Pabx Information Manual. The Mitel manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 171

installation Forms 
TABLE 3-14 (CONT’D) 
TRUNK CIRCUIT DESCRIPTOR OPTIONS 
SHEET _ OF _ 
E&M CARD OPTIONS 
Remote End is a 
Satellite (Y or N) 
Remote End is a Satellite with OPS Lines 
(Y or N) 
Dictation Trunk (Y or N) 
Notes: 1. This form is a nested form and can only be accessed from the previous form (Trunk 
Circuit Descriptors). 
2. Specify the hardware options for the selected trunk circuit descriptor number. The 
options can be specified only after a trunk type has been assigned to a trunk...

Page 172

installation Forms 
TABLE 3-14 (CONT’D) 
TRUNK CIRCUIT DESCRIPTOR OPTIONS 
SHEET _ OF _ 
Remote End is a Satellite (Y or N) 
Remote End is a Satellite with OPS Lines (Y 
or N) 
Notes: 1. This form is a nested form and can only be accessed from the previous form (Trunk 
Circuit Descriptors). 
2. Specify the hardware options for the selected trunk circuit descriptor number. The 
options can be specified only after a trunk type has been assigned to a trunk circuit 
descriptor number. 
Page 3-28  

Page 173

Installation Forms 
TABLE 3-14 (CONT’D) 
TRUNK CIRCUIT DESCRIPTOR OPTIONS 
SHEET _ OF _ 
B-CIRCUIT DID OPTIONS ** 
150 ms) x (IO ms 
Wink Timer (150 - 300 ms) x (50 ms 
increments) 
Remote End is a Satellite (Y or N) 
Remote End is a Satellite with OPS Lines (Y 
or N) 
* Generic 1000 ** Generic 1001 
Notes: 1. This form is a nested form and can only be accessed from the previous form (Trunk 
Circuit Descriptors). 
2. Specify the hardware options for the selected trunk circuit descriptor number. The...

Page 174

Installation Forms 
TABLE 3-15 
FORM 14 - NON-DIAL-IN TRUNKS 
SHEET 
-OF - 
CDN 1 TK NUM 1 COMMENTS 
Notes: 1. Specify the COS number, Tenant Group number and the trunk number (1 4 200). 
2. Specify the answer points for Day, Nightl, and Night2 Service Modes. The answer 
points may be specified as an LDN on the Attendant Console, a station number (or a 
SUPERSET@ set Prime Line number), a Hunt Group Access Code or a Night Bell 
equipment extension number. An LDN and Night Bell cannot be rung...

Page 175

Installation Forms 
TABLE 3-16 
FORM 15 - DIAL-IN TRUNKS 
SHEET 
-OF - 
Notes: 1. 
2. 
3. 
4. 
5. 
6. Specify COS number, COR number, Tenant Group number and the trunk number (1 + 
200). 
Assign a trunk circuit descriptor number in the CDN field for each Dial-In Trunk. The 
CDN field links this form to Form 13, Trunk Circuit Descriptors which defines the trunk 
hardware parameters. 
Specify the number of expected digits (1 to 9) if required in the N field. Digit translation 
on incoming calls occurs...

Page 176

Installation Forms 
TABLE 3-17 
FORM 16 - TRUNK GROUPS 
SHEET 
-OF - 
TRUNK GROUP NUMBER (1 - 50): TRUNK GROUP NAME: 
HUNTING (TERMINAL/CIRCULAR): SMDR (Y/N): 
1 Trunk Group Function: 
I 
~~ ~~ TRUNK NUMBERS 
TRUNK GROUP NUMBER (1 - 50): 1 TRUNK GROUP NAME: 
I 
Notes: ‘I. There are maximum of 50 members per Trunk Group and the system supports a 
maximum of 50 Trunk Groups. 
2. Specify each member of the Trunk Group by trunk number. Trunk Group hunting 
occurs in the order that the members are entered....

Page 177

installation Forms 
TABLE 3-18 
FORM 17 - HUNT GROUPS 
SHEET 
-OF - 
HUNT GROUP NUMBER (1 -, 50): ACCESS CODE: 
HUNTING TYPE (TERMINAL/CIRCULAR): HUNT GROUP TYPE: 
Hunt Group Function: 
EXTENSION NUMBERS 
HUNT GROUP NUMBER (1 - 50): 
HUNTING TYPE (TERMINAL/CIRCULAR): 
Hunt Group Function: ACCESS CODE: 
HUNT GROUP TYPE: 
Notes: 1. There are maximum of 50 members per Hunt Group and the system supports a 
maximum of 50 Hunt Groups. 
2. Specify each member of the Hunt Group by extension number. Hunting...

Page 178

Installation Forms 
TABLE 3-19 
FORM 18 - MISCELLANEOUS SYSTEM PORTS 
SHEET 1 OF 2 
27 
28 
29 
30 Night Bell 14 
Night Bell 15 
Night Bell 16 
Night Bell 17 
Page 3-34  

Page 179

Installation Forms 
TABLE 3-19 (CONT’D) 
FORM 18 - MISCELLANEOUS SYSTEM PORTS 
SHEET 2 OF 2 
Notes: 1. Specify the physical location (bay, slot, circuit and subcircuit numbers) of the miscella- 
neous devices. 
2. Specification of the extension numbers is only required for the Night Bell relays. Night 
Bell definitions are restricted to Universal Card slots. 
3. The subcircuit (XT) fields for the music on hold module and the nine paging zones 
will be filled in by the system. 
Page 3-35  

Page 180

Installation Forms 
TABLE 3-20 
FORM 19 - CALL REROUTING TABLE 
TENANT GROUP (1 - 25): SHEET 
-OF - 
I TYPE OF CALL 1 DAY 1 Nl 1 N2 
Station Dial 0 Routing 
Prioritv Dial 0 Routing 
I DID Recall Points on Busy 
I I I 
DID Recall Points on No Answer 
DID Routing for Calls into this Tenant 
I DID Intercept Routing For Calls into this Tenant 
I I I 
DID Vacant Number Routing for this Tenant 
DID Attendant Night Access Points 
1 Non-Dial-In Trunks Alternate Recall Points 
I I I 
Dial-In Tie Recall Points On...
Start reading Mitel SX-200 DIGITAL Pabx Information Manual

Related Manuals for Mitel SX-200 DIGITAL Pabx Information Manual

All Mitel manuals