Page 151

Installation Forms 
TABLE 3-3 (CONT’D) 
FORM 02 - FEATURE ACCESS CODES 
SHEET 2 OF 2 
Number Feature Name Assigned Access Code 
32 ** Call Park 
33 2% 
Node ID 
34 ** Maid in Room 
35 ** SUPERSET qTM Set Room Status Display 
36 ** Direct to ARS 
* Generic 1000 ** Generic 1001 
Notes: 
1. Specify the Feature Access Code in the Assigned Access Code column. 
2. Feature Access Codes can be a maximum of five digits (except for the Callback Busy 
Access Code and the Executive Busy Override Access Code which...

Page 152

TABLE 3-4 
FORM 03 - CLASS-OF-SERVICE OPTIONS 
SHEET _ OF _ 
ATTENDANT-RELATED I 
Option 
Number Class-of-Service Option Name Class-of-Service Number (1 - 50) 
-1 -2 -3 I-4 -5 -6 -7 -8 -9 -0 
Class-of-Service Status 
Timer 10 -+ 60 Seconds Default is 30 Seconds 
* Generic 1000 ** Generic 1001 
Page 3-8  

Page 153

Installation Forms 
TABLE 3-4 (CONT’D) 
FORM 03 - CLASS-OF-SERVICE OPTIONS 
SHEET _ OF _ 
I--- STATION/SUPERSET@- RELATED (CONT’D) 
I 
Class-of-Service Number (1 - 50) 
Option 
Number Class-of-Service Option Name 
-1 I-2 I-3 I-4 I-5 I-6 I-7 I-8 I-9 I-0 
Class-of-Service Status 
210 Call Forwarding inhibit on Dial-In Trunks 
I I 
I I I I 
i211 -1 Call Hold and Retrieve Access I I I I I I I I I I I 
212 
213 
214 
215 Can Flash if Talking to an Incoming Trunk 
Can Flash if Talking to an Outgoing Trunk...

Page 154

TABLE 3-4 (CONT’D) 
FORM 03 - CLASS-OF-SERVICE OPTIONS 
SHEET _ OF _ 
STATION/SUPERSET@- RELATED (CONT’DI 
311 Paging Access - Zone 9 
312 Default Paging Zone (0 Gives All Zones Enabled) 
(O-9) 
I I 
313 ** I 
I I I I 
CO Trunk To CO Trunk Connect 
314 ** CO Trunk To Tie Trunk Connect 
315 *+ CO Trunk To DID Trunk Connect 
316 ** Tie Trunk To Tie Trunk Connect 
I 
317 ** Tie Trunk To DID Trunk Connect 
316 ** DID Trunk To DID Trunk Connect 
I I I 
I I I I 
319 ** Extension Non-Co Trunk to Trunk Connect...

Page 155

Installation Forms 
TABLE 3-4 (CONT’D) 
FORM 03 - CLASS-OF-SERVICE OPTIONS 
SHEET _ OF _ 
I STATION-RELATED 
* Generic 1000 ** Generic 1001 
Page 3-l 1  

Page 156

Installation Forms 
TABLE 3-4 (CONT’D) 
FORM 03 - CLASS-OF-SERVICE OPTIONS 
SHEET _ OF _ 
* Generic 1000 ** Generic 1001 
Notes: 1. Specify the Class-of-Service number (1 - 50). 
2. Specify the enabled options with an “E” for each Class of Service. 
3. Specify the disabled options with a “D” for each Class of Service. 
4. Specify the timer value for the timer options. 
Page 3-12  

Page 157

Installation Forms 
TABLE 3-5 
FORM 04 - SYSTEM OPTIONS/SYSTEM TIMERS 
SHEET 1 OF 1 
Option No. System Options/System Timers 
01 24 Hour Clock Status 
1 02” 1 Account Code Length 4 Digits 
I 
1 02 ** 1 RESERVED 
I I 
03 * Account Code Length 8 Digits 
03 ** RESERVED 
04 * Account Code Length 12 Digits 
r=* I 
Message Waiting and Message 
Register Change Print 
I I 
1~ 05 * I Variable Account Code Length I I 
I 
05 xx 
Verified Account Codes 
Attendant CO Trunk to CO Trunk 
Connect 
RESERVED 
Attendant CO...

Page 158

installation Forms 
TABLE 3-6 
FORM 05 - TENANT INTERCONNECTION TABLE 
I 
01 I 02 I 03 I 04 I 05 I 06 I 07 I 08 I 09 I 10 I 11 I 12 I 13 I 14 I 15 I 16 I 17 I 18 I 19 I 20 I 21 I 22 I 23 I 24 rl 25 
01 0 
02 0 
03 0 
04 0 
05 0 
06 0 
07 0 
08 0 
09 0 
IO 0 
11 0 
12 
0 
13 
0 
14 
0 
15 
0 
16 0 
17 
0 
18 
0 
19 
0 
20 
0 
21 
0 
22 
0 
23 
0 
24 
0 
25 
0 
Notes: 1. Specify all inhibited connections with an X (indicated by a period on the CRT). Tenant 
Group interconnection is inhibited...

Page 159

Installation Forms 
TABLE 3-7 
FORM 06 - TENANT NIGHT SWITCHING CONTROL 
SHEET 1 OF 1 
20  20 
21  21 
I I I I 
22 I I 0 
23 0 
24 0 
25 0 
Notes: 1. Specify with an X those Tenant Groups allowed to switch into Night Service simulta- 
neously (indicated by an asterisk on the CRT). An X in row 10 column 1 allows Tenant 
Group 10 to switch both Tenant Groups 10 and 1 into Night Service simultaneously. 
However, Tenant Group 1 can only switch itself into Night Service. 
2. On initialization, the system...

Page 160

TABLE 3-8 
FORM 07 - CONSOLE ASSIGNMENTS 
SHEET 1 OF 1 
BAY 
Notes: 1. There are a maximum of 11 consoles. The Attendant Console default location is Bay 2, 
Slot 3, Circuit 1. This Attendant Console is required if the VT-100 compatible terminal 
is not used for Customer Data Entry. 
2. Specify the physical location (bay, slot and circuit) of each console. 
3. Specify the extension number of each console. Calls directed to the console’s exten- 
sion number route to softkey 2. However, another extension...