Page 141

installation Forms 
2. SYSTEM INITIALIZATION 
General 
2.01 
When the system is first installed, the default data must be 
loaded into the system. Refer to Chart 2-1, Initial Power-up 
Procedures From the Terminal, Chart 2-2, Initial Power-up Procedures 
From the Attendant Console and refer to Section 
MITL9108-093-200-NA, Shipping, Receiving, and Installation Informa- 
tion for details. 
Page 2-1  

Page 142

Installation Forms 
CHART 2-l 
INITIAL POWER-UP PROCEDURES FROM THE TERMINAL 
1. Ensure that the correct Decryption Module is installed. Refer to Section MITL9108-093- 
200-NA, Shipping, Receiving, and Installation Information. 
2. Turn power supplies ON. 
3. Insert the diskette in the Bay 2 disk drive. Refer to the illustration on the disk drive door 
for the correct diskette orientation. 
4. Close the disk drive door. The disk drive should begin to operate. If not, depress the 
System Reset button on...

Page 143

installation Forms 
CHART 2-2 
INITIAL POWER-UP PROCEDURES FROM THE ATTENDANT CONSOLE 
1. Repeat Steps 1 to 4 from Chart 2-1, Initial Power-up Procedures from the Terminal. 
2. All LEDs on the console light and the LCD displays the following on two rows: 
nnnnoooonnnnonnnono~n~n~n~nnn~ 
------------------------------ 
3. If the HOLD 1 LED flashes then the RAM Test failed. If the HOLD 2 LED flashes, then the 
EPROM Test failed. If the HOLD 3 LED flashes, then the IRQ Interrupt Test failed. Refer to...

Page 144

Installation Forms 
CHART 2-2 (CONT’D) 
INITIAL POWER-UP PROCEDURES FROM THE ATTENDANT CONSOLE 
11. Press the INSTALLER softkey; the console LCD returns the following: 
Enter Password : 
[Fl > [F2 > [F3 > [F4 > 
1~6 > [F7 > 1~8 > IF9 > [F5 > 
[FO >ENTER 
12. Enter the required password and press the ENTER softkey to gain Customer Data Entry 
access. The password is defined in Form 27, Form Access Restriction Definition. The 
default password is 1000. If the correct password is entered, then the Attendant...

Page 145

Installation Forms 
3. CUSTOMER DATA ENTRY FORMS 
General 
3.01 
The following forms enable the installer to configure the sys- 
tem prior to the initial system power-up sequence. Space is 
allocated to record the customer data. Table 3-l lists the available 
forms for the Customer Data Entry package. Special notes for each 
form appear at the end of the form. 
TABLE 3-l 
AVAILABLE FORMS 
FORMS 
01 = SYSTEM CONFIGURATION 
03 = COS DEFINE 
05 = TENANT INTERCONNECTION TABLE 
07 = CONSOLE ASSIGNMENTS 
09 =...

Page 146

Installation Forms 
TABLE 3-2 
FORM 01 - SYSTEM CONFIGURATION 
1 BAY 1 SLT 1 GCT 1 PROGRAMMED I COMMENTS I 
1 1 - 
1 2 - 
1 3 - 
11141-1 
1 5 1 
1 5 2 
1 5 3 
II 1-5 I4 I I I 
1 6 1 
1 6 2 
1 6 3 
1 6 4 
1 7 1 
1 7 2 
k 
1 7 4 
lllslll 
1 8 2 
1 8 3 
FI I 4 I I I 
3 4 - 5 10 - 
3 5 - 5 11 - 
3 6 - 5 12 - 
SHEET 1 OF 4 
Page 3-2  

Page 147

Installation Forms 
TABLE 3-2 (CONT’D) 
FORM 01 - SYSTEM CONFIGURATION 
480-PORT CONFIGURATION 
BAY 1 SLT 1 CCT 1 PROGRAMMED 1 COMMENTS I 
1 1 - 
1 5 1 
II 15 12 I 
1 5 3 
1 5 4 
1 6 1 
11 16 12 1 1 
1 6 3 
1 6 4 
1 7 1 
1 7 2 
II I7131 
1 7 4 
1 6 1 
11 18 12 1 
II 18131 
1 8 4 
2 1 - 
2 2 - 
121311 I 
2 3 2 
2 3 3 
2 3 4 
1214111 
2 4 2 
2 4 3 
2 4 4 
3 1 - 
13121-l 
lalsl-I 
3 4 - 
3 5 - 
3 6 - 
I 
SHEET 2 OF 4 
BAY SLT CC1 PROGRAMMED COMMENTS 
I 
3 7 - 
3 8 - 
3 9 - 
3 IO - 
3 11 - 
4 9 - 
I 
4 12 -...

Page 148

Installation Forms 
TABLE 3-2 (CONT’D) 
FORM 01 - SYSTEM CONFIGURATION 
336-PORT CONFIGURATION 
SHEET 3 OF 4 
BAY SLT CCT PROGRAMMED COMMENTS 
3 5 1  BAY 1 SLT CCT 1 PROGRAMMED COMMENTS 
I 
1 I 1 
I 1 
315121  1 2 
+ 1 3 3 5 3 
3 5 4 I 
‘14 
1 I5 3 6 1 
3 6 2 
3 16 13 1  1 5 
+ 1 5 
‘I I5 3 6 4 
3 7 1 
3 7 2 
317131 
116 
3 7 4 
3 8 1 
3 B 2 
3 8 3  117 
1 7 
* 
1 7 
1 7 3 8 4 
4 1 - 
4 2 - 
4 3 - 
I 
‘I 18 
4 4 - 
4 5 
1 
4 5 2  2 
1 
2 2 
+ 
2 3 
2 3 415131 
4 5 4 
4 6 
1 
4 6 2 
4 6 3 
416 141  2 I3 2...

Page 149

Installation Forms 
Notes: 1. 
2. 
3. TABLE 3-2 (CONT’D) 
FORM 01 
- SYSTEM CONFIGURATION 
SHEET 4 OF 4 
Enter the card type in the PROGRAMMED column. Most slots have no circuit designa- 
tions (represented by a u-n in the CCT column), as the cards for these slots have 
identical circuit types. 
Those slots with circuit designations are high powered slots. The Universal Card must 
be installed in one of these high powered slots. The circuit designations indicate the 
four module positions on the...

Page 150

Installation Forms 
TABLE 3-3 
FORM 02 - FEATURE ACCESS CODES 
SHEET 1 OF 2 
Number Feature Name 
01 Account Code Access 
02 Auto-Answer Activation 
Assigned Access Code 
03 Call Forwarding - Busy 
04 Call Forwarding - Don’t Answer 
05 Call Forwarding - Busv/Don’t Answer 
06 Call Forwarding - Follow Me 
07 Call Forwarding - I’m Here 
08 Dial Call Pickup 
09 Directed Call Pickup 
IO Do Not Disturb 
11 Extension General Attendant Access 
12 1 Paging Access to Default Zone(s) 
I 
13 Paging Access to...