Troubleshooting 9 Issue 2.5 October 1999 9-1 Your console has access to many features that are helpful in troubleshooting various problems. This chapter presents those features, as well as procedures and recommendations that will assist you in isolating and analyzing problems, before escalating them to higher-level support personnel. Refer to the appropriate section in this chapter, according to the type of problem you are attempting to identify and correct. This chapter includes the...
Page 162
Troubleshooting 9-2 Issue 2.5 October 1999 To protect the data on your PC, implement a regular backup procedure. Information can be backed up (stored) on a diskette, tape, or remote network drive. It is also wise to follow a circular backup routine; keeping the last three backup files — and only overwriting information older than that. In the event of a disk failure, you can still access and restore information that is relatively recent. During installation, you must specify the directory...
Page 163
Troubleshooting Issue 2.5 October 1999 9-3 Troubleshooting Problems with the Telephone or PassageWay Adapter Symptom Probable Cause Recommended Solution You cannot use the DCP telephone in the normal manner. This is not a problem. The PC Console environment disables the normal functionality of the telephone. Pressing the Speakerphone button on the DCP telephone produces a dial tone. On the switch side, the port is administered for a DCP telephone. At the switch, re-administer the...
Page 164
Troubleshooting 9-4 Issue 2.5 October 1999 The red light on the PassageWay Adapter, or in the tenth Call Appearance position on the 8411 telephone, remains steadily lighted when PC Console is running. PC Console is administered to use the wrong COM port. Verify that the COM port to which the PassageWay Adapter or 8411 telephone is physically connected is consistent with the port identified in the System Parameters folder of the System Administration window. If it is not, either reconfigure...
Page 165
Troubleshooting Issue 2.5 October 1999 9-5 Troubleshooting Error Messages Symptom Probable Cause Recommended Solution Error message “Insufficient memory” is displayed. There is not enough available memory to run the PC Console application or related Help files. This may be a hardware-related problem, or it may simply indicate that too many applications are running. Exit the PC Console application. Verify that the PC meets the minimum configuration requirements, including 16 MB of...
Page 166
Troubleshooting 9-6 Issue 2.5 October 1999 When attempting to launch PC Console, a Windows “Error 3520” message is displayed on the screen. “Share” is not enabled on your PC. The PC Console application requires that files be sharable. Close PC Console and all other software applications. Locate your autoexec.bat file. For Windows 3.11, this file is located in your root directory on c:\ Open the file using any text editing software (Notepad, Word, or DOS editing commands, etc.)....
Page 167
Troubleshooting Issue 2.5 October 1999 9-7 When launching PC Console, a warning message indicates “PassageWay not found.” The COM port is not administered correctly, or the PassageWay Adapter, 8411 telephone or CallMaster VI telephone is not receiving power or is not properly connected to the switch. Double-check your installation configuration, and verify that all required connections are correctly made. (Refer to the configuration instructions and options detailed in Chapter 1,...
Page 168
Troubleshooting 9-8 Issue 2.5 October 1999 A General Protection Fault occurs, and the error message indicates PC Console caused the error. The PassageWay Adapter, 8411 telephone, or CallMaster VI telephone has lost connectivity with the switch. Double-check your installation configuration, and verify that all required connections are correctly made. (Refer to the configuration instructions and options detailed in Chapter 1, “Installation.”) Then reboot your PC and relaunch the PC Console...
Page 169
Troubleshooting Issue 2.5 October 1999 9-9 The message “Password table not found” is displayed, and PC Console will not launch. PC Console is unable to locate a password table in the System database. Restore a backup copy of the System database. By default, the System database should be located at pccon2\admin\pccadmin.mdb. The default location of its backup file is pccon2\backup\pccadmin.mdb. If a backup copy is not available, reinstall the PC Console software, being certain to save the...
Page 170
Troubleshooting 9-10 Issue 2.5 October 1999 The message “Password file not found” is displayed, and PC Console will not launch, however the System database has not actually been moved or deleted. The System database has become corrupted. If Microsoft Access 2.0 or later is available to you: Launch Microsoft Access, then open the System database. By default, it is located at pccon2\admin\pccadmin.mdb. Double click on the Password table to open that table. One-by-one, delete all entries...