Page 651
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Screen reference 627 DS1 Circuit Pack 17 Near-end CSU Type This field appears only when the DS1 circuit pack is a TN767D or TN464E or later suffix model, the Bit Rate field is 1.544 and the Country Protocol field is 1 (U.S.). This field does not display for all circuit packs. Alarm When PRI Endpoint Detached Use this field for DS1 circuit packs connected to Roll-About Video equipment. This field appears only when the...
Page 652
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Screen reference 628 DS1 Circuit Pack 17 Field descriptions for page 2 Screen 76. DS1 Circuit Pack !CAUTION: Customers: Do not change fields on this page without assistance from Lucent Technologies or your network service provider. Page 2 does not appear for all DS1 circuit packs. For those circuit packs that support it, this page appears only when: nthe version is V3 or greater nthe Framing Mode field is esf or the...
Page 653
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Screen reference 629 DS1 Circuit Pack 17 Send ANSI-T1.403 One-Second Performance Reports This field selects whether your DS1 circuit pack will send error reports to the far-end switch. These reports are useful for network management, and are sent at 1-second intervals when enabled. This field appears only if the Framing Mode field is esf. It is used only with circuit packs that have an integrated channel service unit...
Page 654
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Screen reference 630 DS1 Circuit Pack 17 Receive ALBO (Receive Automatic Line Build-Out) This field increases the strength of incoming signals by a fixed amount to compensate for line losses. Upon DTE LOS DTE stands for “Data Terminal Equipment.” This field tells the switch what to do if the outgoing signal from the DS1 circuit pack (the data terminal equipment) to the network is lost. Supply CPE Loopback Jack Power...
Page 655
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Screen reference 631 Extended Pickup Group 17 Extended Pickup Group This screen allows grouping of pickup groups into extended pickup groups. This allows users to answer calls outside their immediate group. The maximum number of groups that can be added to an extended pickup group is 25. Field descriptions Screen 77. Extended Pickup Group screen Extended Group Number This display-only field shows the number associated...
Page 656
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Screen reference 632 Extensions Administered to have an MCT-Control Button 17 Pickup Group Number This field determines which call pickup groups can answer calls in the extended pickup group. Extensions Administered to have an MCT-Control Button This screen lists the extensions that can take control of a Malicious Call Trace (MCT) request. In order to give a user the ability to take control of such requests, you need to...
Page 657
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Screen reference 633 Feature Access Code 17 Feature Access Code This screen assigns feature access codes (FACs) that, when dialed, activate or cancel the system features. Each field on this screen has the same valid values, which must conform to feature access codes or dial access codes as defined by your dial plan. Field descriptions for page 1 Screen 79. Feature Access Code (FAC) screen Abbreviated Dialing List1...
Page 658
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Screen reference 634 Feature Access Code 17 Abbreviated Dial - Prgm Group List Access Code Used to enter a group list from a telephone. The user’s extension must be entered on the Abbreviated Dial Group List screen in order to program the group list. Announcement Access Code Used to record announcements. Answer Back Access Code Used to retrieve parked calls. Auto Alternate Routing (AAR) Access Code Used to access AAR....
Page 659
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Screen reference 635 Feature Access Code 17 Call Park Access Code Used to park an active call, which can then be retrieved from a different station using the answer back access code. Do not administer to have the same first digit as another feature access code that is longer in length. Call Pickup Access Code Used to answer a call directed to a pickup group. CAS Remote Hold/Answer Hold-Unhold Access Code Used by a...
Page 660
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Screen reference 636 Feature Access Code 17 Extended Call Fwd Activate Busy D/A Used to activate call forwarding from a telephone or remote location. Extended Call Fwd Activate All Used to activate call forwarding from a telephone or remote location. Extended Call Fwd Deactivation Used to deactivate call forwarding from a telephone or remote location. NOTE: An extension must have Station Security Codes administered to use...