Home > Lucent Technologies > Communications System > Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Installation And Test For Single-Carrier Cabinets Manual

Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Installation And Test For Single-Carrier Cabinets Manual

Here you can view all the pages of manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Installation And Test For Single-Carrier Cabinets Manual. The Lucent Technologies manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 241

DEFINITY Enterprise Communication Server Release 8.2
Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
April 2000
Install and Wire Telephones and Other Equipment 
5-123 Add IP Interface Assembly 
5
3. At the c ommand p romp t, type ping nnn.nnn.nnn.nnn (whic h is the IP 
ad d ress of your g ateway). 
nIf everything  is c onfigured  c orrec tly, the system respond s with the 
following message:
Reply from nnn.nnn.nnn.nnn: bytes=32 time Settings > Control Panel > 
Network
. Selec t...

Page 242

DEFINITY Enterprise Communication Server Release 8.2
Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
April 2000
Install and Wire Telephones and Other Equipment 
5-124 Add IP Interface Assembly 
5
3. At the c ommand  p romp t, typ e ping 192.11.13.8 (whic h is the IP ad d ress of 
the internal p roc essor). 
nIf you have c onnec tivity, the system respond s with the following  
messag e:
Reply from 192.11.13.8: bytes=32 time

Page 243

DEFINITY Enterprise Communication Server Release 8.2
Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
April 2000
Install and Wire Telephones and Other Equipment 
5-125 Add IP Interface Assembly 
5
Connect the Monitor, Keyboard, and Mouse
1. Attac h a VGA monitor to the VGA c onnec tor of the TN802 IP Interfac e 
external c ab le assemb ly.
2. Attac h the keyb oard  to the KEYBOARD c onnec tor of the external c ab le 
assemb ly.
3. Attach the mouse to the MOUSE connector of the...

Page 244

DEFINITY Enterprise Communication Server Release 8.2
Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
April 2000
Install and Wire Telephones and Other Equipment 
5-126 Add IP Interface Assembly 
5
5. When d one, c lic k OK, OK
.
Upgrade to TN802B (R8)
NOTE:
The upg rad e takes ab out 20 minutes.
1. Insert the flash d isk into the rig ht most slot on the TN802 IP trunk. On the 
monitor, a d ialog  b ox assig ns a d rive letter with the removab le med ia 
d esig nation; the d efault...

Page 245

DEFINITY Enterprise Communication Server Release 8.2
Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
April 2000
Install and Wire Telephones and Other Equipment 
5-127 Add IP Interface Assembly 
5
5. Click on Start > Settings > Control Panel > Services
.
6. Select IP Trunk 
and click on Startup
.
NOTE:
Do not c lic k on Start.
7. Under Startup Type, select Disabled
 and  c lic k OK
 to d isab le IP Trunk 
mod e.
NOTE:
If IP trunk and  Med Pro servic es are b oth set to automatic ,...

Page 246

DEFINITY Enterprise Communication Server Release 8.2
Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
April 2000
Install and Wire Telephones and Other Equipment 
5-128 Add IP Interface Assembly 
5
Circuit Pack Verification
1. Type change circuit-pack
 and  p ress En te r.
2. Chec k the Cod e c olumn to see if it says DSMAPD or Med Pro.
.
3. To c orrec t it, g o to the entry just above the TN802B that says DSMAPD.
4. Type MEDPRO, and press 
En t e r. Changing  the one entry...

Page 247

DEFINITY Enterprise Communication Server Release 8.2
Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
April 2000
Install and Wire Telephones and Other Equipment 
5-129 Installing an Integrated Channel Service Unit (ICSU) Module 
5
Installing an Integrated Channel
Service Unit (ICSU) Module
The integ rated c hannel servic e unit (ICSU) is a c omb ination of a 120A CSU 
mod ule integ rated  with a DS1 c irc uit p ac k. Use this d evic e with the 700A DS1 
loop b ac k jac k when...

Page 248

DEFINITY Enterprise Communication Server Release 8.2
Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
April 2000
Install and Wire Telephones and Other Equipment 
5-130 Installing an Integrated Channel Service Unit (ICSU) Module 
5
Installing the 120A CSU
See Fig ure 5-38. 
Figure 5-38. 120A Channel Service Unit Module
!CAUTION:
Do not p lug  the 120A into any c irc uit p ac k other than a TN474F or TN777E 
or later release/vintag e. Do not c onnec t the 120A to any interfac e other...

Page 249

DEFINITY Enterprise Communication Server Release 8.2
Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
April 2000
Install and Wire Telephones and Other Equipment 
5-131 Installing an Integrated Channel Service Unit (ICSU) Module 
5
3.Plug  the 120A’s 25-p air c onnec tor d irec tly into the p lug  assoc iated  with 
the DS1 c irc uit p ac k slot. 
4. Sec ure the 4C retainer around  the 120A.
5. Attac h the sup p lied  H600-383 c able to the 120A and to the network smart 
jac k....

Page 250

DEFINITY Enterprise Communication Server Release 8.2
Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
April 2000
Install and Wire Telephones and Other Equipment 
5-132 Installing an Integrated Channel Service Unit (ICSU) Module 
5
Tab le 5-32 p rovid es the H600-383 c ab le p inouts. Table 5-33 p rovid es the c ab le 
leng ths for eac h c ab le g roup  numb er.
Table 5-32. H600-383 cable Pin Assignments
Pin ColorChannel Service 
Unit DesignationNetwork 
Designation Function
1BK...