Here you can view all the pages of manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Installation And Test For Single-Carrier Cabinets Manual. The Lucent Technologies manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 241
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-123 Add IP Interface Assembly 5 3. At the c ommand p romp t, type ping nnn.nnn.nnn.nnn (whic h is the IP ad d ress of your g ateway). nIf everything is c onfigured c orrec tly, the system respond s with the following message: Reply from nnn.nnn.nnn.nnn: bytes=32 time Settings > Control Panel > Network . Selec t...
Page 242
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-124 Add IP Interface Assembly 5 3. At the c ommand p romp t, typ e ping 192.11.13.8 (whic h is the IP ad d ress of the internal p roc essor). nIf you have c onnec tivity, the system respond s with the following messag e: Reply from 192.11.13.8: bytes=32 time
Page 243
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-125 Add IP Interface Assembly 5 Connect the Monitor, Keyboard, and Mouse 1. Attac h a VGA monitor to the VGA c onnec tor of the TN802 IP Interfac e external c ab le assemb ly. 2. Attac h the keyb oard to the KEYBOARD c onnec tor of the external c ab le assemb ly. 3. Attach the mouse to the MOUSE connector of the...
Page 244
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-126 Add IP Interface Assembly 5 5. When d one, c lic k OK, OK . Upgrade to TN802B (R8) NOTE: The upg rad e takes ab out 20 minutes. 1. Insert the flash d isk into the rig ht most slot on the TN802 IP trunk. On the monitor, a d ialog b ox assig ns a d rive letter with the removab le med ia d esig nation; the d efault...
Page 245
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-127 Add IP Interface Assembly 5 5. Click on Start > Settings > Control Panel > Services . 6. Select IP Trunk and click on Startup . NOTE: Do not c lic k on Start. 7. Under Startup Type, select Disabled and c lic k OK to d isab le IP Trunk mod e. NOTE: If IP trunk and Med Pro servic es are b oth set to automatic ,...
Page 246
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-128 Add IP Interface Assembly 5 Circuit Pack Verification 1. Type change circuit-pack and p ress En te r. 2. Chec k the Cod e c olumn to see if it says DSMAPD or Med Pro. . 3. To c orrec t it, g o to the entry just above the TN802B that says DSMAPD. 4. Type MEDPRO, and press En t e r. Changing the one entry...
Page 247
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-129 Installing an Integrated Channel Service Unit (ICSU) Module 5 Installing an Integrated Channel Service Unit (ICSU) Module The integ rated c hannel servic e unit (ICSU) is a c omb ination of a 120A CSU mod ule integ rated with a DS1 c irc uit p ac k. Use this d evic e with the 700A DS1 loop b ac k jac k when...
Page 248
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-130 Installing an Integrated Channel Service Unit (ICSU) Module 5 Installing the 120A CSU See Fig ure 5-38. Figure 5-38. 120A Channel Service Unit Module !CAUTION: Do not p lug the 120A into any c irc uit p ac k other than a TN474F or TN777E or later release/vintag e. Do not c onnec t the 120A to any interfac e other...
Page 249
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-131 Installing an Integrated Channel Service Unit (ICSU) Module 5 3.Plug the 120A’s 25-p air c onnec tor d irec tly into the p lug assoc iated with the DS1 c irc uit p ac k slot. 4. Sec ure the 4C retainer around the 120A. 5. Attac h the sup p lied H600-383 c able to the 120A and to the network smart jac k....
Page 250
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-132 Installing an Integrated Channel Service Unit (ICSU) Module 5 Tab le 5-32 p rovid es the H600-383 c ab le p inouts. Table 5-33 p rovid es the c ab le leng ths for eac h c ab le g roup numb er. Table 5-32. H600-383 cable Pin Assignments Pin ColorChannel Service Unit DesignationNetwork Designation Function 1BK...