Here you can view all the pages of manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Installation And Test For Single-Carrier Cabinets Manual. The Lucent Technologies manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 281

DEFINITY Enterprise Communication Server Release 8.2
Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
April 2000
Option Switch Settings 
A-11 Call Detail Recording Option Settings 
A
Call Detail Recording Option Settings
The interfac e between the system and  Call Detail Rec ord ing  (CDR) equip ment 
may b e one of the following :
nData Module — Rec ommend ed  op tion setting s are shown in Ta b l e  A - 3.
nMod em — Rec ommend ed  option setting s are in mod em vend or 
document...

Page 282

DEFINITY Enterprise Communication Server Release 8.2
Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
April 2000
Option Switch Settings 
A-12 TN760D Tie Trunk Circuit Pack Option Settings 
A
TN760D Tie Trunk Circuit Pack Option 
Settings
The TN760D Tie Trunk c irc uit p ac k interfac es b etween the tie trunks and  the Time 
Division Multip lex (TDM) b us. Two tip  and ring  p airs form a 4-wire analog  
transmission line. An E and M pair is used for signaling and are DC signaling...

Page 283

DEFINITY Enterprise Communication Server Release 8.2
Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
April 2000
Option Switch Settings 
A-13 TN760D Tie Trunk Circuit Pack Option Settings 
A
Figure A-3. TN760D Tie Trunk Circuit Pack (Component Side)
4321
PORT 4 PORT 3 PORT 2PORT 1 UNPROT
PROTSMPLX
E&MSMPLX
E&MSMPLX
E&MSMPLX
E&M
r758183RBP050896 

Page 284

DEFINITY Enterprise Communication Server Release 8.2
Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
April 2000
Option Switch Settings 
A-14 TN760D Tie Trunk Circuit Pack Option Settings 
A
Table A-9. TN760D Option Switch Settings and Administration
Installation
SituationSet
Prot/
Unprot
Option
Switch Preferred
Signaling FormatSet 
E&M/SMPLX
Option
SwitchAdministered
Port Circumstance To System Far-End
Co-Loc ated Sys75/G1 Simp lex Simp lex SMPLX Either Typ e 5
Typ e 5 Typ e 5...

Page 285

DEFINITY Enterprise Communication Server Release 8.2
Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
April 2000
Option Switch Settings 
A-15 TN464/2464 Option Settings 
A
TN464/2464 Option Settings
The TN464/2464 DS1/E1 Interfac e-T1/E1 c irc uit p ac k interfac es b etween a 24 or 
32 c hannel CO/ISDN or tie trunk and  the Time Division Multip lexing  (TDM) b us.
Set the switc hes on the c irc uit p ac k to selec t b it rate and imp edanc e matc h. See 
Ta b l e  A - 1 0
 and  Fi...

Page 286

DEFINITY Enterprise Communication Server Release 8.2
Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
April 2000
Option Switch Settings 
A-16 TN464/2464 Option Settings 
A 

Page 287

Connecting and Handling Fiber Optic Cables 
B-1 LASER Product 
B
DEFINITY Enterprise Communication Server Release 8.2
Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
April 2000
B
Connecting and Handling Fiber 
Optic Cables
Sig nals b etween the c ab inets c omp osing  the system are c arried  by fib er op tic  
c ab les. To ac c omp lish this, the elec tronic  signals at the c onnec tors on the b ac k 
of a c ab inet must b e c onverted  into op tic al sig nals and op tic al sig...

Page 288

DEFINITY Enterprise Communication Server Release 8.2
Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
April 2000
Connecting and Handling Fiber Optic Cables 
B-2 Optical Cross-Connect Hardware 
B
Optical Cross-Connect Hardware
Optic al c ross-c onnec ts c onsist of Lightg uide Interc onnec t Units (LIUs) with 
lig htg uid e troug hs in b etween them. Fi g u re  B - 1
 shows a typ ic al LIU. One LIU 
terminates the inc oming  c ab les and the other terminates the outg oing  c ab les....

Page 289

DEFINITY Enterprise Communication Server Release 8.2
Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
April 2000
Connecting and Handling Fiber Optic Cables 
B-3 Optical Cross-Connect Hardware 
B
Optic al interc onnec ts c onsist of Lig htg uid e Interc onnec t Units (LIUs) without a 
troug h b etween them. Fi g u re  B - 2
 shows a typ ic al Interc onnec t field. Inc oming  
and  outg oing  multi-mod e and  sing le-mode c ab les are c onnec ted  d irec tly to eac h 
other. This...

Page 290

DEFINITY Enterprise Communication Server Release 8.2
Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
April 2000
Connecting and Handling Fiber Optic Cables 
B-4 Optical Cross-Connect Hardware 
B
100A Lightguide Interconnect Unit
The 100A Lig htg uid e Interc onnec t Unit (LIU) (c omc od e 104141841) c onsists of a 
c ab inet with retainer ring s to hold  slac k fib er c ab les, mounting  c utouts for two 
10A lightg uid e c onnec tor p anels, and a d oor with c irc uit lab els on...
Start reading Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Installation And Test For Single-Carrier Cabinets Manual

Related Manuals for Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Installation And Test For Single-Carrier Cabinets Manual

All Lucent Technologies manuals