Here you can view all the pages of manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Installation And Test For Single-Carrier Cabinets Manual. The Lucent Technologies manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 311

DEFINITY Enterprise Communication Server Release 8.2
Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
April 2000
UPS Installation for SCC EPN A-Carrier Cabinet 
E-5 Make the Remaining Connections 
E
Figure E-2. UPS for Fiber-Remoted SCC EPN Figure Notes
1. 110 c ross-c onnec t field
2. Utility fail wire p air
3. UPS fail wire p air
4. 700A8 (RJ45) mod ular p lug  
(see Figure E-1
 for wiring  d etail)5. Z3A2 UPS alarm ad ap ter p lug s into 
DB25 c onnec tor
6. UPS 800/1000VA
7....

Page 312

DEFINITY Enterprise Communication Server Release 8.2
Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
April 2000
UPS Installation for SCC EPN A-Carrier Cabinet 
E-6 Make the Remaining Connections 
E
Figure E-3. UPS for DS1 Remoted SCC EPNFigure Notes
1. 110 c ross-c onnec t field  
2. Utility fail wire p air
3. UPS fail wire p air
4. 700A8 (RJ45) mod ular p lug  
(see Figure E-1
 for wiring  d etail)
5. Z3A2 UPS alarm adapter plugs 
into DB25 c onnec tor6. UPS 800/1000VA
7. EPN c...

Page 313

DEFINITY Enterprise Communication Server Release 8.2
Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
April 2000
UPS Installation for SCC EPN A-Carrier Cabinet 
E-7 Make the Remaining Connections 
E
Figure E-4. Enlarged View of the 110 Cross-Connect Field for the AUX 
Connector 
Figure Notes
1. Utility fail wire p air:
n1M (major alarm)
nreturn GRD2. UPS fail wire p air:
n1m (minor alarm)
nreturn GRD
X
X
cydfups3 KLC 092899
1
2
1324 

Page 314

DEFINITY Enterprise Communication Server Release 8.2
Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
April 2000
UPS Installation for SCC EPN A-Carrier Cabinet 
E-8 Administer the EDA 
E
Administer the EDA
If the external d evic e alarm (EDA) administration is turned  on:
1. Log in as craft
.
Enter the following  information (XX
 refers to the 2-d ig it c ab inet numb er of the 
EPN ):
2. Type add eda-external-device-alrm XXmajor
 and press 
En t e r.
3. Type XXmajor
 in the Port...

Page 315

DEFINITY Enterprise Communication Server Release 8.2
Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
April 2000
UPS Installation for SCC EPN A-Carrier Cabinet 
E-9 Load Test and Verify Alarms 
E
Load Test and Verify Alarms
!CAUTION:
Do not remove or unp lug  the inp ut c ord  when the UPS is turned  on. This 
removes the safety g round  from the UPS and  the eq uip ment c onnec ted to 
t h e  U PS.
1. With the DEFINITY ECS on the UPS, find  the (d ed ic ated ) c irc uit breaker...

Page 316

DEFINITY Enterprise Communication Server Release 8.2
Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
April 2000
UPS Installation for SCC EPN A-Carrier Cabinet 
E-10 Load Test and Verify Alarms 
E 

Page 317

DEFINITY Enterprise Communication Server Release 8.2
Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
April 2000
GL-1
Glossary and Abbreviations 
 
GL
Glossary and Abbreviations
Numerics
800 service
A service in the United  States that allows incoming c alls from c ertain areas to an assig ned  number 
for a flat-rate c harg e b ased  on usag e.
A
AA
Arc hang el. See 
angel.
AAC
ATM access concentrator
AAR
See  
Automatic  Alternate Routing  (AAR).
abandoned call
An inc oming  c...

Page 318

DEFINITY Enterprise Communication Server Release 8.2
Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
April 2000
Glossary and Abbreviations 
GL-2  
ACD
See Automatic  Call Distrib ution (ACD). ACD also refers to a work state in whic h an ag ent is on 
an ACD call.
ACD agent
See  
ag ent.
ACD work mode
See  
work mod e.
active-notification association
A link that is initiated  b y an ad junc t, allowing  it to rec eive event rep orts for a sp ecific  switch entity, 
such as an outg...

Page 319

DEFINITY Enterprise Communication Server Release 8.2
Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
April 2000
Glossary and Abbreviations 
GL-3  
Adjunct-Switch Application Interface (ASAI)
A recommend ation for interfacing ad juncts and c ommunic ations systems, b ased  on the CCITT 
Q.932 sp ec ific ation for layer 3.
ADM
Async hronous d ata module
administer
To ac cess and  chang e parameters assoc iated  with the servic es or features of a system.
Administered Connection...

Page 320

DEFINITY Enterprise Communication Server Release 8.2
Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
April 2000
Glossary and Abbreviations 
GL-4  
AMW
Automatic  Messag e Waiting
AN
Analog
analog
The rep resentation of information b y c ontinuously variab le p hysical quantities suc h as amp litude, 
freq uency, and p hase. See also 
digital.
analog data
Data that is transmitted  over a d ig ital fac ility in analog  (PCM) form. The d ata must pass throug h a 
mod em either at b...
Start reading Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Installation And Test For Single-Carrier Cabinets Manual

Related Manuals for Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Installation And Test For Single-Carrier Cabinets Manual

All Lucent Technologies manuals