Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Installation And Maintenance For Survivable Remote EPN Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
DEFINITY® Enterprise Communications Server Release 7 Installation and Maintenance for Survivable Remote EPN 555-233-102 Issue 2 June 1999 SREPN Maintenance 2-25 Fault isolation procedures 2 TN2301 has d isc onnec ted from the SREPN, and the SRP is no long er in c ontrol. Connec tions have b een re-estab lished b etween the EI in the SREPN and its EI/SNI c ounterp art in the Release 7r. Fault isolation procedures Use the following p roc ed ure to isolate faults on a fib er link. This sec tion c ontains information on: n‘‘Fib er fault isolation’’ n‘‘Loopback tests’’ Fiber fault isolation !CAUTION: On systems with d up lic ated Port Network Connec tivity (PNC), first b usyout the standby PNC (busyout pnc-standby ) b efore b usying out any of the following standby components: nFiber-Link (FIBER-LK) nSt a n d b y Ex p a n s io n I n t e r f a c e ( EXP- I N TF) nSwitc h Nod e Interfac e (SNI) nDS1 Converter (DS1-CONV) !WARNING: Calls are d rop p ed when b usying out of any of these c omp onents on a simp lex PNC. !CAUTION: Be sure to release all b usied out c omp onents after c omp leting the tests. To isolate fib er link faults use two p roc ed ures: n‘‘Gather information’’ n‘‘Test the fib er link hard ware’’ Gather information 1. Know whic h fiber sp an to isolate b y using the link information (status health ) reports from b oth the Release 7r and the SREPN and the information in Tab le 2-7 . 2. Enter display alarms and press En t e r.
DEFINITY® Enterprise Communications Server Release 7 Installation and Maintenance for Survivable Remote EPN 555-233-102 Issue 2 June 1999 SREPN Maintenance 2-26 Fault isolation procedures 2 3. Type pnc in the Category field , then c hoose En t e r. NOTE: Sinc e the system is in Survive mod e, the Release 7r thinks it has lost its c onnec tions to the EPN. Therefore, alarms may b e p resent, even thoug h the p rob lem has been diag nosed and fixed . 4. Look for any on-b oard alarms other than the EI c irc uit p ac k. If there are any, rep lac e the c irc uit p ac k. Do not rep lac e the EI c irc uit p ac k unless there are on-board alarms. If No, 5. Enter display errors and press En te r. 6. Type pnc in the Category field , then c hoose En t e r. 7. Check for any of the following errors: 8. If you find one or more of the ab ove errors, g o to Step 10. 9. If you find none o f t h e e r ro r s in St e p 7 , t h e n re s o l v e a n y SN I -PEER e r ro r s . a . I f t h e re is o n e SN I c irc u i t p a c k w i t h m a n y d i ff e re n t SN I - PEER e rro r types, replace the indicated SNI circuit pack b . I f t h e re a re m a n y SN I -PEER e r ro r s o f t h e sa m e e rro r t y p e , re p la c e the indic ted SNI c irc uit pac k using Tab le 2-10 . Maintenance ObjectError Ty p e FIBER-LK Any SN I- B D 51 3 EXP-INTF 257 769 770 1281 1537 3073 3074 3075 3076 3585 3841 3842
DEFINITY® Enterprise Communications Server Release 7 Installation and Maintenance for Survivable Remote EPN 555-233-102 Issue 2 June 1999 SREPN Maintenance 2-27 Fault isolation procedures 2 c . After rep lac ing an SNI c irc uit p ac k, c lear alarms b y exec uting test board UUCSS long clear for all alarmed EXP-INTF c irc uit p ac ks. Wait 5 minutes for any SNI-BD or SNI-PEER alarms to c lear. NOTE: You c an sp eed this p roc ess with clear firmware counters [a-pnc |b-pnc ] for the repaired PNC. 10. Enter list fiber-link to g et the p hysic al loc ation of the fib er-link end p oints. 11. If a DS1 CONV is ad ministered to the fiber-link (DS1 CONV is y ), enter display fiber-link to d etermine the p hysic al loc ation of the DS1 CONV c irc uit p ac ks on the fiber-link. 12. Busyout the fiber link (busyout fiber-link number). 13. Test the fib er link (test fiber-link number long ). 14. If any tests in the sequenc e fail, p roc eed with ‘‘ Test the fiber link hard ware’’ below. Table 2-10. SNI-PEER errors Error Type SNI slot 12 257 3 513 4 769 5 1025 6 1281 7 1537 8 1793 9 2049 13 2305 14 2561 15 2817 16 3073 17 3329 18 3585 19 3841 20 Continued on next page
DEFINITY® Enterprise Communications Server Release 7 Installation and Maintenance for Survivable Remote EPN 555-233-102 Issue 2 June 1999 SREPN Maintenance 2-28 Fault isolation procedures 2 NOTE: Test #759 may fail if SNI c irc uit pac ks are p resent. 15. If all of the tests p ass, c lear the alarms b y exec uting test board UUCSS long clear f o r a l l a la r m e d EXP- I N TF c i rc u i t p a c ks . Wa it 5 m i n u t e s f o r a n y SNI-BD, SNI-PEER, FIBER-LK, or DS1C-BD alarms to c lear. NOTE: Test attemp ted on the EI c irc uit pac k in the SREPN d o not run. NOTE: Th e clear firmware counters [a-pnc | b-pnc] c ommand for the PNC that was rep aired may b e q uic ker than c learing the alarms with the test board UUCSS long clear c ommand . Test the fiber link hardware For eac h end p oint of the fib er link: 1. Busyout the c irc uit p ac k (busyout board UUCSS ). 2. Test the c irc uit p ac k (test board UUCSS long ) and rec ord all test failures. When looking at test results, c onsult the exp lanations for Fig ure 2-17 and Fi g u re 2 - 1 8 later in this c hap ter. 3. Does Board Not Assigned d isp lay for an Exp ansion Interfac e in an EPN ? a. If Ye s, use the test maintenance long c ommand to release an Exp ansion Interfac e that may b e held reset b y an EPN Maintenanc e circuit pack. NOTE: Tests attemp ted on the EI c irc uit p ac k in the SREPN d o not run. 4. If No, Did EXP-INTF Test #242 fail? a. If Yes, rep lac e the EI c irc uit p ac k and the lig htwave transc eiver (if p resent) and g o bac k to Step 12 in the ‘‘ Gather information’’ p roc ed ure ab ove. NOTE: EXP- I N TF Te s t # 2 4 2 r u n s a n o n - b o a rd l o o p a ro u n d if n o l ig h t w a v e transc eiver is c onnec ted to the EI. 5. If No, Did SNI Test #757 fail? a. If Ye s, rep lac e the SNI c irc uit pac k and go b ac k to Step 12 in the ‘‘ Gather information’’ p roc ed ure ab ove.
DEFINITY® Enterprise Communications Server Release 7 Installation and Maintenance for Survivable Remote EPN 555-233-102 Issue 2 June 1999 SREPN Maintenance 2-29 Fault isolation procedures 2 6. If No, Did SNI Test #756 fail? a. If Ye s, rep lac e the SNI c irc uit pac k and the lig htwave transc eiver (if p resent) and g o bac k to Step 12 in the ‘‘ Gather information’’ p roc ed ure ab ove. 7. If No, Did EXP-INTF Test #240 fail? a. If Ye s, rep lac e the EI c irc uit p ac k and g o b ac k to Step 12 in the ‘‘ Gather information’’ p roc ed ure ab ove. 8. If No, D i d Te s t # 2 3 8 ( EXP- I N TF) o r Te s t # 9 8 9 ( SN I ) f a il ? a. If Ye s, replac e the lig htwave transc eivers and fib er-op tic c ab le and g o b ac k to Step 12 in the ‘‘ Gather information’’ p roc edure ab ove. b . The faulted c omp onent c an b e further isolated by using information in the ‘‘ Loop b ac k tests’’ sec tion later in this c hap ter. c . If a fib er out of frame c ond ition exists and lig htwave transc eivers are used , c hec k that b oth lig htwave transc eivers are of the same type, (9823A or 9823B). If they are not b oth the same, rep lac e one of the lig htwave transc eivers so that they matc h. 9823A is used for d istanc es up to 4900 feet (1493 m) and 9823B is used for distanc es up to 25,000 feet (7620 m). 9. If No, Is a DS1 CONV ad ministered on the fib er-link? a. If No and the p rob lem is still p resent, follow normal esc alation p roc ed ures. b . If Ye s, is there an SNI-BD 513 alarmed error (display errors for category pnc )? If yes, replace cabling between the SNI circuit pack and the DS1C c irc uit p ac k. c . If the alarm p ersists, first attempt the manual loop b ac k p roc ed ure b elow, then rep lac e the DS1C and the SNI c irc uit p ac ks and g o b ac k to Step 12 in the ‘‘ Gather information’’ p roc ed ure ab ove. 10. If No, if t h e c o n n e c t e d c i rc u it p a c k is a n EXP-I N TF, d i d Te s t # 2 3 8 f a i l? a. If Ye s, re p l a c e c a b l in g b e t w e e n t h e EXP- I N TF c irc u i t p a c k a n d t h e DS1C c irc uit p ac k. If Test #238 c ontinues to fail, rep lac e the DS1C and the EI c irc uit p ac ks and g o b ac k to Step 12 in the ‘‘ Gather information’’ p roc ed ure ab ove. 11. If No, b usyout the c irc uit p ac k (busyout board UUCSS ). 12. Test the c irc uit p ac k (test board UUCSS long) for b oth DS1C c irc uit p ac ks and note all test failures and aborts. NOTE: Test #790 fails with Error Cod e 1 when in Survive mod e.
DEFINITY® Enterprise Communications Server Release 7 Installation and Maintenance for Survivable Remote EPN 555-233-102 Issue 2 June 1999 SREPN Maintenance 2-30 Fault isolation procedures 2 13. Did the test return Board not inserted for the near-end c irc uit p ac k (nearest the SPE), o r f o r t h e f a r- e n d c irc u i t p a c k i n a s im p l e x PN C ? a. If Ye s, replac e the c abling b etween the DS1C c irc uit p ac k and the SNI or EI c irc uit p ac k. b . Wait 1 minute and retest. c . If the b oard is still not inserted , rep lac e the DS1C c irc uit p ac k and the EI or SNI c onnec ted to it and Go b ac k to Step 12 in the ‘‘ Gather information’’ p roc ed ure ab ove. 14. If No, visually c hec k to see if any CSU d evic es are loop ed b ac k. a. Busyout the c irc uit p ac k (busyout board UUCSS ). b. Test for external loopback (test ds1-facility UUCSS external-loop ) for eac h DS1 fac ility. NOTE: Many tests p ass if the system is in Survive mod e. 15. Did Test #788 p ass and Test #789 fail? a. If yes, rep lac e the DS1C and lig htwave transc eiver (if p resent) at the other end of the DS1C c omplex. (See Figure 2-18 ) b . Go b ac k to Step 12 in the ‘‘ Gather information’’ p roc ed ure ab ove. 16. If No, d id Test #788 fail or ab ort and Test #789 fail or abort? a. If Ye s, enter test ds1-facility UUCSS long for eac h ad ministered and eq uip p ed DS1 fac ility. NOTE: If the Switc h Nod e Interfac e (SNI) b oard ’s yellow LED is fast flashing (0.1 sec on/0.1 sec off), it c an ind ic ate a p rob lem with the fib er from the SNI b oard to the SREPN. For more d etailed information, refer to the SNI-BD Maintenanc e Ob jec t in Chap ter 9 of DEFINITY ECS Release 7 Maintenanc e for R7r . Loopback tests The following section d escrib es loop b ack tests: n‘‘Fib er d irec t-c onnec t system’’ n‘‘DS1 CONV system’’ n‘‘Manual loop bac k p roc ed ure’’
DEFINITY® Enterprise Communications Server Release 7 Installation and Maintenance for Survivable Remote EPN 555-233-102 Issue 2 June 1999 SREPN Maintenance 2-31 Fault isolation procedures 2 Fiber direct-connect system Fi g u re 2 - 1 7 shows the loopbacks performed on the SNI and EI circ uit packs. Figure 2-17. Fiber fault isolation tests for SNI and EI circuit packs Fi g u re 2 - 1 7 shows that: nTest #756 rep orts the result of the off-b oard loop b ac k nTest #757 rep orts the result of the on-board loop b ac k nTest #756 and Test #757 c an run ind ivid ually or as p art of the test board UUCSS long c ommand for an SNI c irc uit p ac k. nTest #242 c an b e run as p art of the test board UUCSS long c ommand for an Exp ansion Interfac e c irc uit p ac k. In ad d ition to testing on-board c omp onents, this test is helpful for isolating p rob lems between a c irc uit p ac k and the lig htwave transc eiver . The loop b ac k shown in this d iag ram shows only part what Test #242 d oes. If no lig htwave transc eiver is c onnec ted to the Exp ansion Interfac e c irc uit p ac k, an on-b oard loop b ac k is p erformed on the Exp ansion Interfac e c irc uit p ac k. For more information about Test #242, see the EXP-INTF Maintenanc e Ob jec t in Chap ter 9 of DEFINITY ECS Release 7 Maintenanc e for R7r . cydf058 RPY 022499 TN753 switch node interfaceTN570C expansion interface Te s t # 757Te s t # 756Te s t # 242Tone clock Tone detector DEFINITY ECSSREPN TDM BUS Fiber optic cable Back of cabinetBack of cabinet Lightwave transceivers Test #989 (framing)Test #989 (framing)
DEFINITY® Enterprise Communications Server Release 7 Installation and Maintenance for Survivable Remote EPN 555-233-102 Issue 2 June 1999 SREPN Maintenance 2-32 Fault isolation procedures 2 DS1 CONV system Ad d itional DS1-CONV loop b ac k tests c an further isolate the p rob lem as shown in Fi g u re 2 - 1 8 . Figure 2-18. DS1 CONV loopback tests Fi g u re 2 - 1 8 shows that: nIf Test #799 fails at LB1, the p rob lem is with DS1C #1, CSU #1, or the c onnec tions b etween them. nIf Test #799 p asses at LB1 and fails at LB2, the p rob lem is with CSU #1. nIf Test #799 p asses at LB1 and at LB2, the p rob lem is with the DS1 fac ility, CSU #2, c onnec tions to CSU #2, or DS1C #2. nFor more information about loopb ac k Tests #788 and #789 (isolates the lig htwave transc eiver), see the DS1 CONV-BD sec tion in Chap ter 9 of DEFINITY ECS Release 7 Maintenanc e for R7r. Manual loopback procedure Lightwave transc eivers are not isolated as p art of Exp ansion Interfac e or DS1-CONV c irc uit p ac k tests. For examp le, when the Exp ansion Interfac e Lightwave Transc eiver Loop around Test (#242) and the Exp ansion Interfac e Loc al Loop Around Test #240 p ass, this ind ic ates that the Exp ansion Interfac e c irc uit p ac k is func tioning prop erly, b ut it d oes not verify that the op tic al p ortion of the lig htwave transc eiver is func tioning p rop erly. To b eing the manual loop bac k p roc ed ure: 1. If d up lic ate Exp ansion Interfac e Links are availab le, issue the test board UUCSS c ommand on the stand by Exp ansion Interfac e c irc uit p ac ks on b oth end s of fib er. cydf059 KLC 022499 DS1C DS1CCSU CSU DEFINITY ECS SREPN Lightwave transceiverTest #797 loops at internal interface for DS1 facility Test #789 loops here DS1 facilityTest #799 LB2Test #799 LB1Tests 780, 788, 797 799 start here
DEFINITY® Enterprise Communications Server Release 7 Installation and Maintenance for Survivable Remote EPN 555-233-102 Issue 2 June 1999 SREPN Maintenance 2-33 Fault isolation procedures 2 2. If this test p asses from b oth sid es, b ut other tests fail, suc h as Test #241, this c ond ition ind ic ates either a faulty lig htwave transc eiver or a faulty fib er c ab le. To d etermine if either a lig htwave transc eiver or the fib er itself has failed, exec ute the Exp ansion Interfac e ‘‘ Manual loop b ac k proc ed ure’’ described below. NOTE: This test c an only b e run from b oth Exp ansion Interfac e c irc uit p ac ks if they are the Stand by pair, and if the Ac tive p air is working p rop erly. Use this p roc ed ure when nUsing DS1 CONV fac ilities and a 9823A lig htwave transc eiver. nAn EI/SNI c irc uit p ac k c annot b e tested b y software. For examp le, an EI c irc uit p ac k loc ated in an EPN that is d own c annot b e tested . This c an oc c ur when c ommunic ation b etween the switc h nod e c arrier and the SPE is d own. !WARNING: This procedure is destructive; all calls are broken down. To b eg in the manual loop bac k p roc ed ure: 1. Run the c onfig uration aud it test (#759) on SNI c irc uit pac ks where possible with test board UUCSS s . 2. Run the Proc essor Route Aud it Test (#760) with the test board UUCSS long c ommand for the ac tive SNC in the switc h nod e c arrier. If the ac tive SNC is not inserted , Test #760 c an b e run with test hardware-group pnc a-pnc or b-pnc . 3. Determine whether more than one SNI is unab le to c ommunic ate with software. Verify SNI and SNC c irc uit p ac k insertion with the list configuration carrier UUC c ommand and c hec k for SNI and SNC insertion for every ad ministered switc h nod e c arrier. 4. If all of the SNIs and SNCs are not inserted (No Board d isp lays for eac h b oard) in the entire PNC (either the a-p nc or the b -p nc ), then the link b etween the PPN EI (on the PNC where SNI and SNC c irc uit p ac ks did not insert) and the c onnec ted SNI is not func tioning prop erly. a. Run the test board UUCSS c ommand on the PPN EI and fix any p rob lems found . b . Perform the manual loop b ac k p roc ed ure for the PPN EI. c . Perform the manual loop b ac k p roc ed ure for the SNI c onnec ted to t h e PPN EI . d . Rep lac e the ac tive SNC.
DEFINITY® Enterprise Communications Server Release 7 Installation and Maintenance for Survivable Remote EPN 555-233-102 Issue 2 June 1999 SREPN Maintenance 2-34 Fault isolation procedures 2 5. If the system has a two-level switc h node c arrier c onfig uration, that is (all must ap p ly) nSNI-SNI fib er links exist nThe SNIs and SNCs in the sec ond switc h nod e c arrier only (the switc h nod e c arrier that has no SNI c onnec ted to the PPN EI) are not inserted nAt least two SNI-SNI fib er links exist Then perform the following steps: a. Run the test board UUCSS long c ommand on the SNIs in the first switc h nod e c arrier that are c onnec ted to SNIs in the sec ond switc h nod e c arrier and fix any p roblems found . b . Rep lac e the ac tive SNC. c . Perform the manual loop b ac k p roc ed ure for the SNIs in the sec ond switc h nod e c arrier that are c onnec ted to SNIs in the first switc h nod e c arrier. 6. If software is unab le to c ommunic ate with an EPN EI, but c an c ommunic ate with the c onnec ted SNI: a. Run the test board UUCSS long c ommand on the c onnec ted SNI and fix any p rob lems found . b . Busyout the EI or SNI c irc uit p ac k (busyout board UUCSS ). 7. Disc onnec t the transmit and rec eive fib er p air from the fib er c onnec tors on the b ac k of the c ab inet. NOTE: Note whic h is the transmit and whic h is the rec eive sid e for p roper re-c onnec tion at the end of this p roc ed ure.