Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Installation And Maintenance For Survivable Remote EPN Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
DEFINITY® Enterprise Communications Server Release 7 Installation and Maintenance for Survivable Remote EPN 555-233-102 Issue 2 June 1999 SREPN Installation 1-19 Administer the Release 7r and SRP 1 2. Disp lay the hard ware in the SREPN b y typ ing display circuit-packs (the port network number of the SREPN) and pressing En t e r. NOTE: The p ort network numb ers d iffer b etween the Release 7r and the SRP. On the Release 7r manag ement terminal, the p ort network that you may b e d isp laying is 5; whereas, on the SRP management terminal, the p ort network that you are ad d ing c irc uit p ac ks to is always 2. 3. On the SRP manag ement terminal, typ e change circuit-packs 2 and p ress En t e r. All the c irc uit p ac ks d isp layed on the Release 7r manag ement terminal that are not Release 7r spec ific (suc h as p ac ket g ateways or DS1CONV) must b e ad d ed to the SRP. Be sure to ad d c irc uit p ac ks to all nec essary c arriers. NOTE: Save often the information you ad d to the SRP manag ement terminal. 4. Press En t e r. Administering the software 1. Set the c ustomer op tions on the SRP to c losely matc h the Release 7r op tions. Identify and add trunk information Ad ministration for eac h of the c irc uit p ac ks in the SREPN need s to be ad d ed to the SRP. For every trunk c irc uit p ac k, the trunk ad ministration must b e ad d ed and for every p ort on every line c irc uit p ac k, the station ad ministration must b e added. 1. On the Release 7r management terminal, typ e list configuration port-network (numb er of the SREPN p ort network) and p ress En t e r. Id entify the slot numbers of the trunk c irc uit p ac ks. 2. For eac h trunk c irc uit p ac k on the Release 7r manag ement terminal, typ e display port (where CCSS01 is the c irc uit p ac k and p ort loc ation of the first p ort on the trunk c irc uit p ac k) and p ress En t e r. The Port Information sc reen ap pears. The Identification: field shows the trunk g roup and memb er information for that p ort. (For example, 98/1 means that this p ort is memb er 1 of trunk g roup 98.) 3. Type display trunk-group (numb er is the trunk g roup memb er) and p ress En t e r. 4. On the SRP manag ement terminal, typ e add trunk-group and p ress En t e r.
DEFINITY® Enterprise Communications Server Release 7 Installation and Maintenance for Survivable Remote EPN 555-233-102 Issue 2 June 1999 SREPN Installation 1-20 Administer the Release 7r and SRP 1 5. Ad d all of the trunk group information (d isp layed on the Release 7r manag ement terminal) to the SRP management terminal. NOTE: The p ort network numb ers d iffer b etween the Release 7r and the SRP. On the Release 7r manag ement terminal, the p ort network that you may b e d isp laying is 5; whereas, on the SRP management terminal, the p ort network that you are ad d ing c irc uit p ac ks to is always 2. 6. The Memb er Assig nments sc reen on the Release 7r manag ement terminal ap p ears. Note the numb er of the memb ers in the trunk g roup. Are all the p orts for that trunk c irc uit p ac k memb ers of that trunk? nIf yes, ad d the memb ers, p ress En te r and rep eat step s 2-6 for the next trunk c irc uit p ac k. nIf no, rep eat step 2 for all the p orts on the trunk c irc uit p ac k that are not ac c ounted for in that trunk g roup. (For examp le, if trunk g roup 98 has only 4 memb ers, whic h c orrespond to p orts 1 - 4, return to step 2 and typ e display port and p ress En te r to d etermine the trunk g roup for p ort 5.) Then follow step s 3 and 4 with the new trunk g roup information. NOTE: For more information ab out ad ministering trunks, refer to D EFI N I TY Enterprise Communic ations Server Release 7 Ad ministration and Feature Desc rip tion . 7. Type save translation and press En te r. Identify and add station information 1. On the Release 7r management terminal, typ e list configuration port-network (numb er of the SREPN p ort network) and p ress En t e r. Id entify the slot numbers of the line c irc uit p ac ks. 2. For eac h line c irc uit p ac k on the Release 7r management terminal, typ e display port (where CCSS01 is the c irc uit p ac k and p ort loc ation of the first port on the line c irc uit p ac k) and p ress En t e r. The Port Information sc reen ap pears. The Identification: field shows the typ e of station and its extension for that port. 3. Type display station (extension of the station) and p ress En t e r. NOTE: The d isp lay c ommand d ep end s on the ad ministration of that p ort - display station for stations, display data for d ata terminals, and so forth.
DEFINITY® Enterprise Communications Server Release 7 Installation and Maintenance for Survivable Remote EPN 555-233-102 Issue 2 June 1999 SREPN Installation 1-21 Administer the Release 7r and SRP 1 4. On the SRP manag ement terminal, typ e add station (extension is the same station extension as ab ove) and p ress En t e r. 5. Dup lic ate all of the station information d isp layed on the Release 7r manag ement terminal to the SRP manag ement terminal. NOTE: Rememb er to ad d any ad d itional system ad ministration that may b e need ed . For examp le, if the station has a c overag e path, you need to ad minister the c overage p ath. Some of the ad ministration for the station may not work if the SREPN g oes into survive mod e (suc h as coverage paths, abbreviated dial lists, and bridged appearances). 6. Repeat steps 2 - 5 for every port on every line c irc uit pack in the SREPN. NOTE: For more information ab out ad ministering stations, refer to DEFINITY Enterprise Communic ations Server Release 7 Ad ministration and Feature Desc rip tion. 7. Type save translation and press En te r. Identify and add other circuit packs For c irc uit p ac ks other than trunk and line, follow the same guid elines. 1. Disp lay eac h p ort on the c irc uit p ac k and the eq uip ment typ e d isp layed on the p ort information sc reen. 2. Disp lay the eq uip ment on the Release 7r manag ement teminal and ad d the information to the SRP manag ement terminal. 3. Type save translation and press En te r. Administering the system features NOTE: Customer options availab le to the SRP are the same as those availab le on the existing Release 7r. These are ad ministered b y the reg ional CSA. Any d ifferenc es in features from the Release 7r to Release 7si are exp erienc ed in the survivab le mod e. Refer to the Release 7r and Release 7si feature ad ministration d esc rip tions for further d etails. System ad ministration need s to b e ad d ed to the SREPN inc lud ing d ialp lan, system features, system maintenanc e, system sec urity, feature-ac c ess-c od es, and so forth. Administer in the same manner as listed ab ove. 1. Disp lay the information on the Release 7r manag ement terminal. For examp le, typ e display feature-access-codes and p ress En te r.
DEFINITY® Enterprise Communications Server Release 7 Installation and Maintenance for Survivable Remote EPN 555-233-102 Issue 2 June 1999 SREPN Installation 1-22 Administer the Release 7r and SRP 1 2. Ad d the information to the SRP manag ement terminal. For examp le, typ e change feature-access-codes and press En te r. 3. Type save translation (optional) and press En te r. Administering the maintenance parameters Pag e 1 of the system-p arameters maintenanc e form c ontains 2 fields that must b e ad ministered for the ab b reviated alarm rep ort. Fi g u re 1 - 9 shows the sc reen with the First OSS Telephone Number: and Second OSS Telephone Number: field s that are ad ministered with offsite notific ation numb ers. The Abbrev Alarm Report? field s assoc iated with these numb ers must be set to avoid unnec essary notific ation c alls. 1. Set the two Abbreviated Alarm Report field s to y and p ress En t e r. Figure 1-9. Maintenance-related system parameters screen Administering the sync source NOTE: Do not ad minister a trunk on the SREPN as the sync hronization sourc e for the Release 7r. If the system g oes into the survive mod e, the Release 7r loses its sync source. change system-parameters maintenance Page 1 of 3 SPE A MAINTENANCE-RELATED SYSTEM PARAMETERS OPERATIONS SUPPORT PARAMETERS Product Identification: 1010101010 First OSS Telephone Number: 9~p5380532 Abbrev Alarm Report? y Second OSS Telephone Number: 9~p5380533 Abbrev Alarm Report? y Alarm Origination to OSS Numbers: both Cleared Alarm Notification? y Suspension Threshold: 5 Restart Notification? y Test Remote Access Port? y CPE Alarm Activation Level: none Customer Access to INADS Port? y Repeat Dial Interval (mins): 7 SCHEDULED MAINTENANCE Start Time: 23 : 00 Stop Time: 06 : 00 Daily Maintenance: daily Save Translation: daily Control Channel Interchange: daily System Clocks Interchange: daily SPE Interchange: daily
DEFINITY® Enterprise Communications Server Release 7 Installation and Maintenance for Survivable Remote EPN 555-233-102 Issue 2 June 1999 SREPN Installation 1-23 Replace Release 7r circuit packs 1 To administer the sync sourc e for the SRP: 1. On the SRP manag ement terminal, typ e change synchronization and p ress En t e r. 2. Enter a DS1 trunk c irc uit p ac k on the SRP as the primary sync sourc e. 3. Press En t e r. NOTE: When the system is in the survive mod e, the sync hronization of the SRP c omes from the DS1 trunk c irc uit p ac k. When the system is in the normal mod e, the sync hronization of the SRP reverts b ac k to the tone c loc k and c auses a sync alarm in the alarm log s of the SRP. 4. When all ad ministration is c omp leted on the SRP, typ e save translation and p ress En t e r. 5. Return the TN2301 switc h to the AUTO p osition. Replace Release 7r circuit packs If the Release 7r has the TN574 DS1CONV c irc uit p ac k: 1. Rep lac e the TN574 DS1CONV c irc uit p ac k with the TN1654 DS1CONV circuit pack. 2. If you have a TN573 SNI c irc uit p ac k, rep lac e it with a TN573B SNI c irc uit pack. Replace EPN circuit packs and make cable connections 1 . Po w e r d o w n t h e EPN . 2. If this is a p reviously installed EPN, then remove the DS1CONV to EI c ab le. 3. Install the TN775C maintenanc e c irc uit p ac k. 4. Install the TN570C exp ansion interfac e c irc uit p ac k. 5. Rep lac e the TN574 c irc uit p ac k with the TN1654 DS1CONV c irc uit p ac k. 6.Dep end ing on the c ustomer’s c onfig uration, refer to one of the following sec tions: n‘‘Connec t DS1CONV c ab les for standard /hig h reliab ility’’ n‘‘Connec t DS1CONV c ab les for c ritic al reliab ility’’ n‘‘Connec t d irec t fib er c ab les for stand ard /hig h reliab ility’’ n‘‘Connec t d irec t fib er c ab les for c ritic al reliab ility’’
DEFINITY® Enterprise Communications Server Release 7 Installation and Maintenance for Survivable Remote EPN 555-233-102 Issue 2 June 1999 SREPN Installation 1-24 Replace EPN circuit packs and make cable connections 1 Connect DS1CONV cables for standard/high reliability 1. Connec t the eq uip ment as shown in Fig ure 1-10. 2. Power up the EPN. 3. Go to the ‘‘ Test the SRP’’ sec tion. Connect DS1CONV cables for critical reliability 1. Connec t the eq uip ment as shown in Fig ure 1-11. 2. Power up the EPN. 3. Go to the ‘‘ Test the SRP’’ sec tion. Connect direct fiber cables for standard/high reliability 1. Connec t the eq uip ment as shown in Fig ure 1-12. 2. Power up the EPN. 3. Go to the ‘‘ Test the SRP’’ sec tion. Connect direct fiber cables for critical reliability 1. Connec t the eq uip ment as shown in Fig ure 1-13. 2. Power up the EPN. 3. Go to the ‘‘ Test the SRP’’ sec tion.
DEFINITY® Enterprise Communications Server Release 7 Installation and Maintenance for Survivable Remote EPN 555-233-102 Issue 2 June 1999 SREPN Installation 1-25 Replace EPN circuit packs and make cable connections 1 Figure 1-10. EPN DS1CONV standard/high reliability cable connectionsFigure Notes 1. MCC c ab inet 2. EPN c arrier A 3. DS1 c ab le from Port Network Connec tivity (PNC) A link 4. DS1CONV 2-foot (60.96 c m) Y c ab le (Tie wrap the cab le to the c ab inet.) 5. 9823A transceiver 6. 9823A transceiver on the EI connec tor7. B25A 25-p air c ab le 8. Main Distribution Frame (MDF) 9. Fib er op tic cab les 10. From the EPN A TX and RX connec tors on the rear of the SRP 11. From the PPN A TX and RX connec tors on the rear of the SRP cydf1sds RPY 030998 2 4 R XT X 1 3 6 4 2 5 10 119 9 7 3 8
DEFINITY® Enterprise Communications Server Release 7 Installation and Maintenance for Survivable Remote EPN 555-233-102 Issue 2 June 1999 SREPN Installation 1-26 Replace EPN circuit packs and make cable connections 1 Figure 1-11. EPN DS1CONV critical reliability cable connectionsFigure Notes 1. MCC c ab inet 2. EPN c arrier B 3. EPN c arrier A 4. DS1 c ab les from Port Network Connec tivity (PNC) A and B links 5. DS1CONV 2-foot (60.96 c m) Y c ab le (Tie wrap the cab le to the c ab inet.) 6. 9823A transceiver 7. 9823A transceiver on the EI connec tor8. B25A 25-p air c ab le 9. Fib er op tic cab les 10. From the EPN B TX and RX connec tors on the rear of the SRP 11. Main Distribution Frame (MDF) 12. From the EPN A TX and RX connec tors on the rear of the SRP 13. From the PPN A TX and RX connec tors on the rear of the SRP 14. From the PPN B TX and RX connec tors on the rear of the SRP 2 45 RX T X cydfhdsa RPY 030698 1 10 12 13 14 4 5 6 7 7 8 9 9 74 5 RX T X 6 2 3 9 9 11
DEFINITY® Enterprise Communications Server Release 7 Installation and Maintenance for Survivable Remote EPN 555-233-102 Issue 2 June 1999 SREPN Installation 1-27 Replace EPN circuit packs and make cable connections 1 Figure 1-12. EPN Direct fiber standard/high reliability cable connectionsFigure Notes 1. SCC cab inet 2. 9823A transceiver on the EI connec tor 3. B25A 25-p air cab le 4. Main Distrib ution Frame (MDF)5. Fib er op tic cab le 6. From the EPN A TX and RX connec tors on the rear of the SRP cabinet cydf1epn RPY 030998 1 2 4 6 3 5
DEFINITY® Enterprise Communications Server Release 7 Installation and Maintenance for Survivable Remote EPN 555-233-102 Issue 2 June 1999 SREPN Installation 1-28 Replace EPN circuit packs and make cable connections 1 Figure 1-13. EPN Direct fiber critical reliability cable connectionsFigure Notes 1. MCC c ab inet 2. EPN c arrier B 3. EPN c arrier A 4. 9823A transceiver on the EI connec tor 5. Fib er op tic cab les6. From the EPN B TX and RX connec tors on the rear of the SRP 7. Main Distribution Frame (MDF) 8. B25A 25-p air c ab le 9. From the EPN A TX and RX connec tors on the rear of the SRP cydfhep2 RPY 030998 1 2 3 4 4 95 567 8