Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Installation And Maintenance For Survivable Remote EPN Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
DEFINITY® Enterprise Communications Server Release 7 Installation and Maintenance for Survivable Remote EPN 555-233-102 Issue 2 June 1999 SREPN Maintenance 2-35 Fault isolation procedures 2 8. Connec t the transmit and rec eive c ab les tog ether using the fib er op tic c oup ler (Comc od e 407643014, p rovided in Maintenanc e Kit #30) to c reate a loop as shown in Fig ure 2-19 . Figure 2-19. Manual loopback with fiber optic coupling 9. Go to the front of the c ab inet and inspec t the yellow LED. a. If the yellow LED flashes on at a rate of onc e p er sec ond , the Exp ansion Interfac e or Switc h Nod e Interfac e c irc uit p ac k or transc eiver should b e rep lac ed . b . If the yellow LED flashes on at a rate of 5 times p er sec ond , the Exp ansion Interfac e or Switc h Nod e Interfac e c irc uit p ac k or the lig htwave transc eiver may need rep lac ement. This c ond ition may also b e d ue to a faulty system c loc k on the network c ontaining the Exp ansion Interfac e c irc uit pac k or in the switc h nod e c arrier containing the SNI. c . If the yellow LED was b linking b efore starting this proc ed ure and the yellow LED is not b linking now, this c irc uit p ac k (Exp ansion Interfac e or Switc h Nod e Interfac e) and the lig htwave transc eiver are func tioning p rop erly. Figure Notes 1. Fib er op tic coup ling (Comcod e 407643014) RX RX TX TX cydfloop LJK 032398 Back of cabinet 1
DEFINITY® Enterprise Communications Server Release 7 Installation and Maintenance for Survivable Remote EPN 555-233-102 Issue 2 June 1999 SREPN Maintenance 2-36 Fault isolation procedures 2 10. Rep lac e faulty c omp onent(s) and rec onnec t the orig inal fib er. Be sure to rec onnec t the fib ers p rop erly as noted in Step 7 in this ‘‘ Manual loop bac k p roc ed ure’’ section. 11. Release the Exp ansion Interfac e c irc uit p ac k or Switc h Nod e Interfac e c irc uit p ac k (release board UUCSS ). 12. If p rob lems still exist after the Manual Loop b ac k Proc edure ind ic ates that b oth Exp ansion Interfac e c irc uit p ac ks and b oth lig htwave transc eivers are healthy, verify that eac h op tic al fib er is c onnec ted to a transmitter at one end and a rec eiver at the other. DS1 interface cable pinout Table 2-11 shows the p in assig nments for the c ab le c onnec ting the TN1654 DS1 CONV c irc uit p ac k to DS1 fac ilities.
DEFINITY® Enterprise Communications Server Release 7 Installation and Maintenance for Survivable Remote EPN 555-233-102 Issue 2 June 1999 SREPN Maintenance 2-37 Fault isolation procedures 2 Table 2-11. DS1 Interface Cable Connectors Lead Desig.50-Pin Connector Pin #15-Pin Connector Color Pin Color Plug 04 Fac ility D Line In LID 38 W-BL 11 W-BL Fac ility D Line In LID* 13 BL-W 03 BL-W Fac ility D Line Out LOD 39 W-O 09 W-O Fac ility D Line Out LOD* 14 O-W 01 O-W Plug 03 Fac ility C Line In LIC 41 W-G 11 W-G Fac ility C Line In LIC* 16 G-W 03 G-W Fac ility C Line Out LOC 42 W-BR 09 W-BR Fac ility C Line Out LOC* 17 BR-W 01 BR-W Plug 02 Fac ility B Line In LIB 44 W-S 11 W-S Fac ility B Line In LIB* 19 S-W 03 S-W Fac ility B Line Out LOB 45 R-BL 09 R-BL Fac ility B Line Out LOB* 20 BL-R 01 BL-R Plug 01 Fac ility A Line In LIA 47 R-O 11 R-O Fac ility A Line In LIA* 22 O-R 03 O-R Fac ility A Line Out LOA 48 R-G 09 R-G Fac ility A Line Out LOA* 23 G-R 01 G-R Continued on next page
DEFINITY® Enterprise Communications Server Release 7 Installation and Maintenance for Survivable Remote EPN 555-233-102 Issue 2 June 1999 SREPN Maintenance 2-38 110 block cross-connect pins 2 110 block cross-connect pins Table 2-12. 110 block cross-connect pins SRP AuxEPN Aux Amphenol Pin Number ColorCross- Connect Pin NumberLead Designation 1 1. When the loop b etween Cust A (alarm) and Cust Rtn (return) c loses, the SRSwitc h c onfigures the SRP into Restore mod e, overriding the fac ep late switc h setting . Closure of the c ustomer alarm relay is c ontrolled b y an SRP SAT c ommand whic h c loses the c ustomer alarm relay on the SRP p roc essor. Pwr Fail (-48V) is g round ed when the TN2301 d etec ts that its -48V red und ant p ower is b ad . Cust A (alarm) - see ab ove. SRPresent is always g round ed , indic ating to the TN775C (Maint.) that it is c onnec ted in a SREPN. SRAc tive is g enerated b y TN775C (Maint.) to d isc onnec t links from Release 7r to SRP in Survive mod e. -48V In/Rtn is inp ut and return used by DC/DC c onverter for sup p lying red und ant p ower to the op tic al transc eivers. SR Cntrl/Rtn, when ac tive, c onnec ts to the SR Cntrl Rtn signal on the TN775C (Maint.). Loop c losed - TN2301 goes into Survive mod e; loop op en - TN2301 c annot c ome out of Survive mode without manual or remote reset. Cross- Connect Pin Number ColorAmphenol Pin Number 23 G-V 46 Cust Rtn 3 W-O 27 SRP AuxSRP Switch Amphenol Pin Number ColorCross- Connect Pin NumberLead DesignationCross- Connect Pin Number ColorAmphenol Pin Number 27 W-O 3 Pwr Fail (-48V) 46 G-V 23 48 V-G 45 Cust A 23 BK-O 37 EPN AuxSRP Switch Amphenol Pin Number ColorCross- Connect Pin NumberLead DesignationCross- Connect Pin Number ColorAmphenol Pin Number 02 O-W 4 Cust Rtn 24 O-BK 12 28 W-G 5 SRPresent 47 V-BR 49 29 W- B R 7 SRA c t i ve 4 8 BR- V 24 46 V-BL 41 -48V Rtn 41 V-BL 46 21 BL-V 42 -48V In 42 BL-V 21 48 V-G 45 2 2. Momentarily short these two lead s on the EPN Aux to verify the d etec tion c irc uit on the TN2301 and the Maintenanc e (TN775C) c irc uit pac k wiring . SR Cntrl 43 V-O 47 23 G-V 46 2SR Cntrl Rtn 44 O-V 22
DEFINITY® Enterprise Communications Server Release 7 Installation and Maintenance for Survivable Remote EPN 555-233-102 Issue 2 June 1999 SREPN Maintenance 2-39 Replacing the TN2301 circuit pack 2 Fi g u re 2 - 2 0 shows the p inout and c ross-c onnec tions for the SREPN. Figure 2-20. SREPN pinout and connections Replacing the TN2301 circuit pack !CAUTION: EPN service is interrupted until a replacement TN2301 is installed, powered up , and the EI links restored . Unseat the circuit pack 1. Power d own the c ab inet b y turning the p ower switc h off. 2. Attac h an ESD strap to your wrist. Figure Notes 1. Switc hes to g round after link failure (ap p roximately 3 minutes)2. Momentary c losure after 3 minutes A-PNC B-PNC ABEI EI EISRP TN 2301 SR Switch Latch Latch Reset TN 790 processor R6R PPN47SRPresent (V-BR) (W-G) Aux_Alm_3 48 41 42 43 44 24 46 23SRActive (BR-V) -48v. Rt (BL-V) SRCnt1 (V-O) SRCntRt (O-V) CustRtn (O-BK) PwrFail (G-V) -48v. (V-BL)5 7 41 42 45 46 4 3 (W-BR) Aux_Alm_4 (V-BL) Grd (BL-V) -48v. -48v. (V-G) Ext_Alm (G-V) Ext_Alm_Rt (O-W) Grd (W-O) Aux_Alm_2 Maintenance/Test TN775C EPN Aux EPNAux_Alm_2 (W-O) Y cable3 46 Ext_Alm_Rt (G-V) Ext_Alm (V-G) 45CustA (BK-O) SR Switch SRP Aux 1 2 iodf001 EWS 111198
DEFINITY® Enterprise Communications Server Release 7 Installation and Maintenance for Survivable Remote EPN 555-233-102 Issue 2 June 1999 SREPN Maintenance 2-40 Replacing the TN2301 circuit pack 2 3. Push the latc h p in up ward to unloc k the loc king lever. 4. Pull d own on the loc king lever until the c irc uit p ac k d isc onnec ts from its soc ket. 5. Pull the c irc uit pac k just enoug h to b reak c ontac t with the bac kp lane c onnec tor, b ut d o not remove it from the c ab inet. !CAUTION: Ensure that there is enoug h slac k d rawn from the extra fib er op tic c ab ling from the bottom p an of the c ab inet to c lear the c irc uit p ac k from the c ab inet (ap p roximately 18 inc hes or 45.7 c m). Replace the circuit pack NOTE: If the same op tic al transc eivers c an b e reused , then the op tic al c onnec tions to the transc eivers d o not have to b e removed. Just remove the transc eivers from the old c irc uit p ac k and rec onnec t them to the c orresp ond ing c onnec tor p ositions on the rep lac ement c irc uit p ac k. 1. Remove the fib er c onnec tions from eac h transc eiver, taking c are to note to whic h transc eiver the c ab les g o and whic h is the transmit (TX) and rec eive (RX) c onnec tions for eac h transc eiver. See Fig ure 2-2 1.
DEFINITY® Enterprise Communications Server Release 7 Installation and Maintenance for Survivable Remote EPN 555-233-102 Issue 2 June 1999 SREPN Maintenance 2-41 Replacing the TN2301 circuit pack 2 Figure 2-21. Transceivers attached to the TN2301 circuit pack 2. Remove the b rac ket and then the transc eivers from the old c irc uit p ac k and rep lac e them in the id entic al positions on the new TN2301 c irc uit pack. 3. Rep lac e the b rac ket over the transc eivers to sec ure them to the b oard . 4. Feed the fib er c ab les throug h the slot in the b ac k of the c irc uit p ac k and rep lac e the fib er c onnec tions on eac h of the transc eivers. Figure Notes 1. Connec tions from PPN A (lig htwave transc eiver typ e must match other end ) 2. Connec tions to EPN A 3. Connec tions from PPN B 4. Connec tions to EPN B5. Lig htwave transc eiver (9823A is always in this p osition) 6. Fib er op tic cab le p airs from the rear p anel of the SRP c ab inet ckdf03fo KLC 010899 R XT X R XT X 1 2 3 4 5 6 PPN A EPN A PPN B EPN B
DEFINITY® Enterprise Communications Server Release 7 Installation and Maintenance for Survivable Remote EPN 555-233-102 Issue 2 June 1999 SREPN Maintenance 2-42 Restore from remote location 2 5. Insert the new c irc uit p ac k, feed ing the fiber p atc h c ord s to the b ottom p an of the c ab inet. Reseat the circuit pack 1. Reseat the c irc uit pac k into the b ac kp lane c onnec tor. !WARNING: Ensure that the fib er c ab les are not b ent or p inc hed b etween the b ac k of the c irc uit p ac k and the b ac kp lane of the c ab inet. 2. Lift the loc king lever until the p in engag es. 3. Power up the c ab inet. Restore from remote location Th e restore survivable-remote-link c ommand rec onfig ures the EI link c onnec tions to the Release 7r PPN just as if the fac ep late switc h was manually set to the RSTR (Restore) p osition. NOTE: The TN2301 fac ep late switc h p osition overrid es the restore survivable-remote-link c ommand , should the two c onflic t. Onc e the c onnec tion to the Release 7r is repaired : 1. Dial in and log onto the SRP p roc essor. 2. Typ e the restore survivable-remote-link c ommand , whic h c loses the relay on the Proc essor c irc uit p ac k. 3. Wait at least 3 minutes while the EPN g oes throug h its c old restart and then c hec k the status of the link c onnec tions with the status health command for both the Release 7r and the SRP systems to d etermine whether the link b etween the Release 7r and the EPN is up (Fi g u re 2 - 9 ). When the c onnec tions are up on b oth sid es (EPN and Release 7r), the system is suc c essfully rec onnec ted .
DEFINITY® Enterprise Communications Server Release 7 Installation and Maintenance for Survivable Remote EPN 555-233-102 Issue 2 June 1999 SREPN Maintenance 2-43 Restore from remote location 2 Th e Tab le 2-13 d esc rib es the c ond itions in whic h the restore from a remote loc ation is p ossib le. Table 2-13.TN2301 switch configuration based on input Inputs to Control Logic Modes Remote restoreSurvive mode requested 1 1. The EPN Maintenance (TN775C) c irc uit p ac k req uests switc hing to Survive mod e. Switch positionSRP power State of SREPN Not activeNot activeAUTOGoodNormal mod e: EPN c onnected with Release 7r PPN Not activeActiveAUTOGoodSurvive mode: EPN c onnec ted to SRP Not activeDoes not matterTESTGoodSurvive mode: EPN c onnec ted to SRP ActiveDoes not matterTESTGoodSurvive mode: EPN c onnec ted to SRP Not activeDoes not matterRSTRGoodNormal mod e: EPN connec ted to Release 7r PPN Not activeDoes not matterRSTRBadNormal mod e: EPN c onnected with Release 7r PPN ActiveDoes not matterAUTO or RSTRGoodNormal mod e: EPN connec ted to Release 7r PPN Continued on next page
DEFINITY® Enterprise Communications Server Release 7 Installation and Maintenance for Survivable Remote EPN 555-233-102 Issue 2 June 1999 SREPN Maintenance 2-44 System links 2 System links The state of a system link is d ep end ent on the state of the various hard ware c omp onents that it travels over. The switc h maintains a list of hard ware c omp onents over whic h the link travels, c alled the hard ware p ath. For eac h system link there is a c urrent and a faulted hard ware p ath as shown in Tab le 2-14 . 1. Foc us attention on the c urrent hardware path for p rob lems that d o not involve a link that is d own. 2. If the link is down, foc us on the faulted hard ware p ath. 3. If any alarms are p resent, follow the maintenanc e p roc ed ures for the alarmed c omp onents to c lear those alarms first. Table 2-14. Hardware path data for link repair Hardware pathLink statusHardware path data present?Errors cleared at recovery? CurrentUp Yes Yes Down No Yes Faulted 1 1. Path that the link traversed when it last went d own.Up Yes Down Yes 2 2. The time at whic h the faulted p ath was last rec ord ed is p reserved and is ac c essib le throug h the status sys-link loc ation, whic h shows the state of b oth the hardware paths (current and faulted ) and the state of eac h of the comp onents in that path, and the list sys-link command s. No