Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Installation And Maintenance For Survivable Remote EPN Manual
Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Installation And Maintenance For Survivable Remote EPN Manual
Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Installation And Maintenance For Survivable Remote EPN Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
DEFINITY® Enterprise Communications Server Release 7 Installation and Maintenance for Survivable Remote EPN 555-233-102 Issue 2 June 1999 SREPN Maintenance 2-5 SREPN connections 2 Expansion Interface connections nTN570C Exp ansion Interfac e (EI) c irc uit p ac ks use either the 9823A (multimod e) or the 300A (sing le mod e) transc eivers. NOTE: A new SREPN system inc lud es the TN570C EI c irc uit p ac k. Earlier EI c irc uit pac ks (for examp le, TN570B) are not sup p orted . DS1 CONV connections nTN1654 DS1 Converter sup p orts T1/E1 remoting and wid eband applications. nStand ard and Hig h Reliab ility systems use p airs of TN1654, not mixed with the earlier TN574. nCritic al Reliab ility systems req uire TN1654 c irc uit p ac ks on the d up lic ate pair.
DEFINITY® Enterprise Communications Server Release 7 Installation and Maintenance for Survivable Remote EPN 555-233-102 Issue 2 June 1999 SREPN Maintenance 2-6 SREPN connections 2 Transfer sequence to Survive mode Transfer from Normal to Survive mode is automatic and is c ontrolled b y the TN775C Maintenanc e b oard . Fi g u re 2 - 3 shows a schematic of the link switc hing within the TN2301 c irc uit p ac k. Figure 2-3. TN2301 link switching schematic The transfer seq uenc e to Survive mod e is: 1. Links from the Release 7r PPN to one of its c onfig ured SREPNs fail. 2. The TN775C Maintenanc e c irc uit p ac k (A-c arrier SREPN) d etec ts the link failure and sig nals the TN2301 to d isc onnec t its links to the Release 7r and c onnec t the SREPN Exp ansion Interfac e. 3. The TN790B Survivab le Remote p roc essor (SRP) takes over c ontrol of the EPN in Survive mod e on Link A. Link B is left op en while the SRP is in c ontrol of the SREPN. NOTE: In Survive mod e, the SRSwitc h (TN2301) p uts the EI/SNI c irc uit p ac k in the Release 7r into loop b ac k mod e. Figure Notes: 1. Release 7r 2. Survivable Remote EPN (SREPN)3. SRSwitc h (TN2301) 4. Survivab le Remote p roc essor (R7si) cydfsrp2 KLC 022499 AA BBTN2301 1 3 4 AB 2
DEFINITY® Enterprise Communications Server Release 7 Installation and Maintenance for Survivable Remote EPN 555-233-102 Issue 2 June 1999 SREPN Maintenance 2-7 SREPN connections 2 Tab le 2-3 shows the sequenc e of events to transfer to the Survive mod e, the ap p roximate times for eac h event, and the servic e affec ted at eac h stag e. TN2301 (SRSwitch) The SRSwitc h c irc uit p ac k (TN2301) oc c up ies 6 slots in the SRP c ab inet. Fi g u re 2-4 shows the fac ep late switc h and LEDs for the TN2301 c irc uit p ac k. Table 2-3. Transfer sequence to Survivable Remote mode If the link between the Release 7r and an EPN is down for Then Service affected 1 minute Emerg enc y Transfer Mod e activated . Only established c alls p reserved. 1 1. Similar to Emerg enc y Transfer mod e, only established , intra-EPN calls are preserved . No new or originating calls can be made. 2-3 minutesSystem “ waits” to d etermine whether the Release 7r is g oing throug h a reset 3. 3 minutes Survive mod e activated for eac h SREPN. 2 2. Transfer to Survive mod e inc lud es a cold restart of the SREPN.Estab lished c alls terminated (restart) 5-6 minutes Transfer seq uenc e c omp leted ; EPN servic e restored.Intra-EPN c alls p ossib le 3 3. Calls using the link b ac k to the Release 7r are not p ossib le.
DEFINITY® Enterprise Communications Server Release 7 Installation and Maintenance for Survivable Remote EPN 555-233-102 Issue 2 June 1999 SREPN Maintenance 2-8 SREPN connections 2 Figure 2-4. TN2301 faceplate switch and LEDs Faceplate switch Tab le 2-4 ind ic ates the 3 p ositions for the fac ep late switc h and the use for eac h. Table 2-4. Faceplate switch positions and uses Label Position Use RSTR Top Forc es c ontrol to the Release 7r b y switc hing from Survive mod e to Normal mod e 1 1. This switc h p osition overrid es the restore survivable-remote-link command from the SAT terminal. See ‘‘Restore from remote location’’ later in this chapter for more information. AUTO Mid dle Ready to g o into Survive mod e. The switc h should be in this p osition excep t d uring installation, testing , or releasing the SRP from Survive mod e. TEST Bottom Forc es control to the SRP (Survive mode). Links to the SREPN are throug h the SRP (TN790B Proc essor). 1 !CAUTION: This is for installation and testing only. Do not leave the switc h in this p osition. ckdf02fo RPY 022398 BKUP DATA AUTO RSTR AUTO TEST SURVIVE MODE ON
DEFINITY® Enterprise Communications Server Release 7 Installation and Maintenance for Survivable Remote EPN 555-233-102 Issue 2 June 1999 SREPN Maintenance 2-9 SREPN connections 2 SREPN connections Fi g u re 2 - 5 shows a d etailed view of the rear p anel c onnec tors. Figure 2-5. SREPN rear panel - detail scdfsre4 RPY 022398 PI EI TX S.R. SW ITCHEPN B EPN APPN B PPN A TX TX TX RX RX RX RXAUX DCE TERM
DEFINITY® Enterprise Communications Server Release 7 Installation and Maintenance for Survivable Remote EPN 555-233-102 Issue 2 June 1999 SREPN Maintenance 2-10 SREPN connections 2 Fi g u re 2 - 6 shows the hard ware c onnec tions in the d irec t fib er system. Figure 2-6. Detailed SRP direct fiber connections Figure Notes: 1. Fib er transmit (TX) and rec eive (RX) p airs for A and B c arriers. 2. SRP AUX B25A 25-p air c ab le; max. leng th = 50 ft. (15.25 m): nMajor SRP p ower failure alarm lead nRemote restore sig nal lead s 3. TN2301 - SRSwitc h B25A 25-p air cable; max. length = 50’ (15.25 m): n-48V from SREPN (through wall field) nSRSwitc h -48V major SRP p ower failure alarm lead nSRSwitc h -48V sig nal lead s4. SREPN AUX c onnec tor B25A 25-p air c ab le; max. leng th = 50 ft. (15.25 m). Refer to the ‘‘ MDF c onnec tions’’ in Chap ter 1: n-48V to SRSwitc h (throug h wall field ) nSRP A la r m nSRSwitc h sig nal lead s 5. Fib er transc eivers (9823A) 6. 14-inc h (35.5 c m) Y-Cab le (Comc od e 847245750) 7. Fib er op tic c able pairs 8. Release 7r switc h cydfsrpn KLC 011199 A B E I E IT N 7 7 5 CB-carrier A-carrier AUX System Access Terminal E I E I SRPSREPN cabinets 5 52 Collocated equipment 1 2 3 48 S.R. switchA B 5 5 7 6 EI AUXTransmit (TX) and receive (RX) fiber pair Wall field LGIU
DEFINITY® Enterprise Communications Server Release 7 Installation and Maintenance for Survivable Remote EPN 555-233-102 Issue 2 June 1999 SREPN Maintenance 2-11 SREPN connections 2 Fi g u re 2 - 7 shows the hard ware c onnec tions in the DS1-CONV system. Figure 2-7. Detailed SRP DS1-CONV connections Figure Notes: 1. Fib er transmit (TX) and rec eive (RX) p airs for A and B c arriers. 2. SRP AUX B25A 25-p air c ab le; max. leng th = 50 ft. (15.25m): nMajor SRP p ower failure alarm lead nRemote restore sig nal lead s 3. TN2301 - SRSwitc h B25A 25-p air c ab le; max. length = 50 ft. (15.25m): n-48V from SREPN throug h wall field nSRSwitc h -48V power failure alarm lead nSRSwitc h sig nal lead s4. SREPN AUX c onnec tor B25A 25-p air c ab le; max. leng th = 50 ft. (15.25m). Refer to the ‘‘ MDF connections’’ in Chapter 1: n-48V to SRSwitc h throug h wall field nSRP A la r m nSRSwitc h sig nal lead s 5. TN1654 (DS1C) c an b e used only in c ombination with another TN1654. 6. Fib er transc eivers (9823A - multimod e) 7. 14-inc h (35.5 c m) Y-Cab le (Comc od e 848101440) 8. Fib er op tic c able pairs 9. Release 7r switc h cydfsrn2 KLC 011199 A A B B D S 1 CE I D S 1 CE IT N 7 7 5 CB-carrier A-carrier CSU CSU Wall field System Access Terminal D S 1 CS N I S N I D S 1 C SRPSREPN cabinets DS1 5 52 Collocated equipment AUX S.R. switch EI AUX 9 1 2 3 4 5 5 5 66 6 6 7 8 8 Transmit (TX) and receive (RX) fiber pair
DEFINITY® Enterprise Communications Server Release 7 Installation and Maintenance for Survivable Remote EPN 555-233-102 Issue 2 June 1999 SREPN Maintenance 2-12 Maintenance procedure 2 Maintenance procedure Sinc e Survive mod e is invoked bec ause of a link failure b etween the Release 7r and an EPN, the maintenanc e strateg y is to: 1.‘‘ Check system status’’ 2.‘‘Rep air the link c onnec tion’’ 3.‘‘Rec onnec t the Release 7r to the EPN’’ 4.‘‘Post-reset check’’ The final sec tions of this c hap ter p rovid e information for resolving n‘‘Power alarms’’ n‘‘System resets’’ Check system status Beg in the troub leshooting p roc ess b y g athering information ab out the system c omp onents. n‘‘Circ uit pac k LEDs’’ n‘‘Whic h EPN is survivab le?’’ n‘‘EI interac tions’’ n‘‘Testing the TN2301 func tion and wiring’’ n‘‘Health of Port Network Connec tions (PNC)’’ n‘‘Ad ministered links’’ Circuit pack LEDs SRSwitch (TN2301) LED interpretation Tab le 2-5 lists the c ond itions ind ic ated b y the LEDs on the TN2301 c irc uit p ac k. Table 2-5. TN2301 LED interpretation LED (color) Condition Interpretation BKUP - Backup p ower (red )On stead y Backup p ower (-48v) from the SREPN to the TN2301 has failed . DATA (yellow) On stead y Data p assing throug h the TN2301 to/from the A-c arrier EI b o a r d i n t h e EPN . Continued on next page
DEFINITY® Enterprise Communications Server Release 7 Installation and Maintenance for Survivable Remote EPN 555-233-102 Issue 2 June 1999 SREPN Maintenance 2-13 Maintenance procedure 2 Expansion Interface (TN570C) LED interpretation The Exp ansion Interfac e c irc uit p ac k has red , g reen, and yellow LEDs. The red and g reen LEDs show the stand ard c ond itions: nRed ind ic ates an alarm c ond ition nGreen ind ic ates maintenanc e testing in p rog ress The yellow LED is used to p rovid e useful visual status information: nAc tive EI c irc uit p ac ks: — Have their yellow LED on solid (for an inter-EPN EI in a d irec t-c onnec t system) — Blink a p attern of 2 sec ond s on and 200 ms off. nThe stand b y PNC EI c irc uit p ac ks should have their yellow LEDs off. NOTE: Another way to d etermine whic h PNC (and therefore, whic h EI in a p ort network) is ac tive and whic h is stand b y, use the status port-network and status PNC commands. See Tab le 2-6 for the p ossib le EI yellow LED states. Off If off and no servic e-affec ting c ond itions are p resent, Critic al Reliab ility B-c arrier links to the Release 7r are up . AUTO (g reen) On stead y Indic ates that the TN2301 fac eplate switc h is in the AUTO p osition. This is normal when in-service. SU RVI VE M OD E ON (red )On stead y Survive mode ac tivated either b y the Maintenanc e c irc uit p ack c ontrol or the facep late switch is in the TEST position. Table 2-5. TN2301 LED interpretation — Continued LED (color) Condition Interpretation Continued on next page
DEFINITY® Enterprise Communications Server Release 7 Installation and Maintenance for Survivable Remote EPN 555-233-102 Issue 2 June 1999 SREPN Maintenance 2-14 Maintenance procedure 2 Table 2-6. Expansion Interface circuit pack Yellow LED Flashing States Condition LED On LED Off Fib er Out-of-Frame 1 1. This flashing state c orresp onds to Error Codes 769 and 770 from the Hard ware Error Log and ind icates a failure of Test #238. These error cod es are usually ac c ompanied by Error Cod e 1281 (no Exp ansion Interfac e or Switc h Nod e Interface detected on op p osite end of fib er). This condition may b e c aused by the ab sence of the neig hb or Exp ansion Interfac e or Switc h Nod e Interface circuit p ac k, a b roken or missing fiber, or a missing lig htwave transc eiver on either end p oint (Exp ansion Interfac e or Switch Nod e Interface c irc uit p ac ks). When the SRP is in Survive mode, this flash rate at the Release 7r EI/SNI circ uit pac k is normal, b ecause the TN2301 puts the fib er into loop around b ac k to the Release 7r. 0.1 second 0.1 sec ond In Frame-No Neig hb or 2 2. This c orresp ond s to Error Cod e 1281 from the Hard ware Error Log and ind ic ates a failure of Test #237. This condition is usually d ue to the failure of this Expansion Interface c irc uit p ack or a failed Exp ansion Interfac e or Switc h Nod e Interfac e c irc uit p ac k c ounterp art. When the SRP is in Normal mode, the Expansion Interfac e c ircuit p ack’s yellow LED flashes at this rate. THIS IS NORMAL. The links to its c ounterp art in the R7r ARE down and are not re-established until the SRP g oes into Sur v iv e m od e . 0.5 second 0.5 sec ond Exp ansion Interface Active 3 3. This is the normal state for an Ac tive EPN Expansion Interfac e c ircuit p ac k that is also the bus master (Exp ansion Arc hang el) in the EPN.2 sec ond s 0.2 sec ond Exp ansion Interface Active 4 4. This is the normal state for an Ac tive Exp ansion Interface circuit p ack that is not the bus master (Exp ansion Arc hang el) for an EPN. This ap p lies only in d irect-c onnec t config urations where the Exp ansion Interface circuit p ack in an EPN is c onnec ted throug h a fib er link to an Exp ansion Interfac e circuit p ac k in the other EPN. This state also ap p lies for an active Exp ansion Interfac e c irc uit p ac k located in the PPN.Solid on Never off Exp ansion Interface Standb y 5 5. This is the normal state for a stand b y Expansion Interface c ircuit p ac k in the PPN a nd EPN . Never on Solid off Continued on next page