    Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Installation And Maintenance For Survivable Remote EPN Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							DEFINITY® Enterprise Communications Server Release 7 Installation and 
    Maintenance for Survivable Remote EPN  555-233-102  Issue 2
    June 1999
    SREPN Maintenance 
    2-5 SREPN connections 
    2
    Expansion Interface connections
    nTN570C Exp ansion Interfac e (EI) c irc uit p ac ks use either the 9823A 
    (multimod e) or the 300A (sing le mod e) transc eivers.
    NOTE:
    A new SREPN system inc lud es the TN570C EI c irc uit p ac k. Earlier EI 
    c irc uit pac ks (for examp le, TN570B) are not sup p orted .
    DS1 CONV connections
    nTN1654 DS1 Converter sup p orts T1/E1 remoting  and  wid eband  
    applications.
    nStand ard  and  Hig h Reliab ility systems use p airs of TN1654, not mixed  with 
    the earlier TN574.
    nCritic al Reliab ility systems req uire TN1654 c irc uit p ac ks on the d up lic ate 
    pair. 
    						
    							DEFINITY® Enterprise Communications Server Release 7 Installation and 
    Maintenance for Survivable Remote EPN  555-233-102  Issue 2
    June 1999
    SREPN Maintenance 
    2-6 SREPN connections 
    2
    Transfer sequence to Survive mode
    Transfer from Normal to Survive mode is automatic  and  is c ontrolled  b y the 
    TN775C Maintenanc e b oard . Fi g u re  2 - 3
     shows a schematic of the link switc hing  
    within the TN2301 c irc uit p ac k.
    Figure 2-3. TN2301 link switching schematic
    The transfer seq uenc e to Survive mod e is:
    1. Links from the Release 7r PPN to one of its c onfig ured  SREPNs fail.
    2. The TN775C Maintenanc e c irc uit p ac k (A-c arrier SREPN) d etec ts the link 
    failure and  sig nals the TN2301 to d isc onnec t its links to the Release 7r and  
    c onnec t the SREPN Exp ansion Interfac e.
    3. The TN790B Survivab le Remote p roc essor (SRP) takes over c ontrol of the 
    EPN in Survive mod e on Link A. Link B is left op en while the SRP is in 
    c ontrol of the SREPN.
    NOTE:
    In Survive mod e, the SRSwitc h (TN2301) p uts the EI/SNI c irc uit p ac k in the 
    Release 7r into loop b ac k mod e. Figure Notes:
    1. Release 7r
    2. Survivable Remote EPN (SREPN)3. SRSwitc h (TN2301)
    4. Survivab le Remote p roc essor (R7si)
    cydfsrp2 KLC 022499
    AA
    BBTN2301
    1
    3
    4
    AB
    2 
    						
    							DEFINITY® Enterprise Communications Server Release 7 Installation and 
    Maintenance for Survivable Remote EPN  555-233-102  Issue 2
    June 1999
    SREPN Maintenance 
    2-7 SREPN connections 
    2
    Tab le 2-3 shows the sequenc e of events to transfer to the Survive mod e, the 
    ap p roximate times for eac h event, and  the servic e affec ted  at eac h stag e.
    TN2301 (SRSwitch)
    The SRSwitc h c irc uit p ac k (TN2301) oc c up ies 6 slots in the SRP c ab inet. Fi g u re  
    2-4 shows the fac ep late switc h and  LEDs for the TN2301 c irc uit p ac k.
    Table 2-3. Transfer sequence to Survivable Remote mode
    If the link between 
    the Release 7r and an 
    EPN is down for  Then Service affected
    1 minute Emerg enc y Transfer Mod e activated .
    Only established  c alls 
    p reserved.
    1
    1. Similar to Emerg enc y Transfer mod e, only established , intra-EPN calls are preserved . No new or 
    originating calls can be made. 2-3 minutesSystem “ waits”  to d etermine whether the 
    Release 7r is g oing  throug h a reset 3. 
    3 minutes Survive mod e activated  for eac h SREPN.
    2
    2. Transfer to Survive mod e inc lud es a cold  restart of the SREPN.Estab lished c alls 
    terminated  (restart)
    5-6 minutes Transfer seq uenc e c omp leted ; EPN servic e 
    restored.Intra-EPN c alls p ossib le
    3
    3. Calls using  the link b ac k to the Release 7r are not p ossib le. 
    						
    							DEFINITY® Enterprise Communications Server Release 7 Installation and 
    Maintenance for Survivable Remote EPN  555-233-102  Issue 2
    June 1999
    SREPN Maintenance 
    2-8 SREPN connections 
    2
    Figure 2-4. TN2301 faceplate switch and LEDs
    Faceplate switch
    Tab le 2-4 ind ic ates the 3 p ositions for the fac ep late switc h and  the use for eac h.
    Table 2-4. Faceplate switch positions and uses
    Label Position Use
    RSTR Top Forc es c ontrol to the Release 7r b y switc hing  from Survive mod e 
    to Normal mod e
    1
    1. This switc h p osition overrid es the restore survivable-remote-link command  from the SAT 
    terminal. See ‘‘Restore from remote location’’ later in this chapter for more information.
    AUTO Mid dle Ready to g o into Survive mod e. The switc h should  be in this 
    p osition excep t d uring  installation, testing , or releasing the SRP 
    from Survive mod e.
    TEST Bottom Forc es control to the SRP (Survive mode). Links to the SREPN are 
    throug h the SRP (TN790B Proc essor).
    1
    !CAUTION:
    This is for installation and testing  only. Do not leave the 
    switc h in this p osition.
    ckdf02fo RPY 022398
    BKUP
    DATA
    AUTO
    RSTR
    AUTO
    TEST
    SURVIVE
    MODE ON 
    						
    							DEFINITY® Enterprise Communications Server Release 7 Installation and 
    Maintenance for Survivable Remote EPN  555-233-102  Issue 2
    June 1999
    SREPN Maintenance 
    2-9 SREPN connections 
    2
    SREPN connections
    Fi g u re  2 - 5 shows a d etailed view of the rear p anel c onnec tors.
    Figure 2-5. SREPN rear panel - detail
    scdfsre4 RPY 022398
    PI EI
    TX S.R.
    SW ITCHEPN B EPN APPN B PPN A
    TX TX TX
    RX RX RX RXAUX
    DCE TERM 
    						
    							DEFINITY® Enterprise Communications Server Release 7 Installation and 
    Maintenance for Survivable Remote EPN  555-233-102  Issue 2
    June 1999
    SREPN Maintenance 
    2-10 SREPN connections 
    2
    Fi g u re  2 - 6 shows the hard ware c onnec tions in the d irec t fib er system.
    Figure 2-6. Detailed SRP direct fiber connections Figure Notes:
    1. Fib er transmit (TX) and rec eive (RX) 
    p airs for A and  B c arriers.
    2. SRP AUX B25A 25-p air c ab le; max. 
    leng th =  50 ft. (15.25 m):
    nMajor SRP p ower failure alarm lead
    nRemote restore sig nal lead s
    3. TN2301 - SRSwitc h B25A 25-p air 
    cable; max. length =  50’  (15.25 m):
    n-48V from SREPN (through wall 
    field)
    nSRSwitc h -48V major SRP p ower 
    failure alarm lead
    nSRSwitc h -48V sig nal lead s4. SREPN AUX c onnec tor B25A 25-p air c ab le; max. 
    leng th =  50 ft. (15.25 m). Refer to the ‘‘
    MDF 
    c onnec tions’’ in Chap ter 1:
    n-48V to SRSwitc h (throug h wall field )
    nSRP A la r m
    nSRSwitc h sig nal lead s
    5. Fib er transc eivers (9823A)
    6. 14-inc h (35.5 c m) Y-Cab le (Comc od e 847245750)
    7. Fib er op tic  c able pairs
    8. Release 7r switc h
    cydfsrpn KLC 011199
    A
    B
    E
    I
    E
    IT
    N
    7
    7
    5
    CB-carrier
    A-carrier
    AUX
    System
    Access
    Terminal
    E
    I
    E
    I
    SRPSREPN cabinets
    5
    52
    Collocated equipment
    1
    2
    3
    48
    S.R.
    switchA B
    5
    5
    7
    6
    EI
    AUXTransmit (TX)
    and receive (RX)
    fiber pair
    Wall field
    LGIU 
    						
    							DEFINITY® Enterprise Communications Server Release 7 Installation and 
    Maintenance for Survivable Remote EPN  555-233-102  Issue 2
    June 1999
    SREPN Maintenance 
    2-11 SREPN connections 
    2
    Fi g u re  2 - 7 shows the hard ware c onnec tions in the DS1-CONV system.
    Figure 2-7. Detailed SRP DS1-CONV connections  Figure Notes:
    1. Fib er transmit (TX) and rec eive (RX) 
    p airs for A and  B c arriers.
    2. SRP AUX B25A 25-p air c ab le; max. 
    leng th =  50 ft. (15.25m):
    nMajor SRP p ower failure alarm lead
    nRemote restore sig nal lead s
    3. TN2301 - SRSwitc h B25A 25-p air 
    c ab le; max. length =  50 ft. (15.25m):
    n-48V from SREPN throug h wall field
    nSRSwitc h -48V power failure alarm 
    lead
    nSRSwitc h sig nal lead s4. SREPN AUX c onnec tor B25A 25-p air c ab le; max. 
    leng th =  50 ft. (15.25m). Refer to the ‘‘
    MDF connections’’ in Chapter 1:
    n-48V to SRSwitc h throug h wall field
    nSRP A la r m
    nSRSwitc h sig nal lead s
    5. TN1654 (DS1C) c an b e used only in c ombination 
    with another TN1654.
    6. Fib er transc eivers (9823A - multimod e)
    7. 14-inc h (35.5 c m) Y-Cab le (Comc od e 848101440)
    8. Fib er op tic  c able pairs
    9. Release 7r switc h
    cydfsrn2 KLC 011199
    A A
    B B
    D
    S
    1
    CE
    I
    D
    S
    1
    CE
    IT
    N
    7
    7
    5
    CB-carrier
    A-carrier
    CSU CSU
    Wall field
    System
    Access
    Terminal
    D
    S
    1
    CS
    N
    I
    S
    N
    I D
    S
    1
    C
    SRPSREPN cabinets
    DS1
    5
    52
    Collocated equipment
    AUX
    S.R.
    switch
    EI AUX
    9
    1
    2
    3
    4
    5
    5
    5
    66
    6
    6
    7
    8
    8
    Transmit (TX)
    and receive (RX)
    fiber pair 
    						
    							DEFINITY® Enterprise Communications Server Release 7 Installation and 
    Maintenance for Survivable Remote EPN  555-233-102  Issue 2
    June 1999
    SREPN Maintenance 
    2-12 Maintenance procedure 
    2
    Maintenance procedure
    Sinc e Survive mod e is invoked  bec ause of a link failure b etween the Release 7r 
    and  an EPN, the maintenanc e strateg y is to:
    1.‘‘
    Check system status’’
    2.‘‘Rep air the link c onnec tion’’
    3.‘‘Rec onnec t the Release 7r to the EPN’’
    4.‘‘Post-reset check’’
    The final sec tions of this c hap ter p rovid e information for resolving
    n‘‘Power alarms’’
    n‘‘System resets’’
    Check system status
    Beg in the troub leshooting  p roc ess b y g athering  information ab out the system 
    c omp onents.
    n‘‘Circ uit pac k LEDs’’
    n‘‘Whic h EPN is survivab le?’’
    n‘‘EI interac tions’’
    n‘‘Testing  the TN2301 func tion and  wiring’’
    n‘‘Health of Port Network Connec tions (PNC)’’
    n‘‘Ad ministered  links’’
    Circuit pack LEDs
    SRSwitch (TN2301) LED interpretation
    Tab le 2-5 lists the c ond itions ind ic ated  b y the LEDs on the TN2301 c irc uit p ac k.
    Table 2-5. TN2301 LED interpretation 
    LED (color) Condition Interpretation
    BKUP - Backup  p ower 
    (red )On stead y Backup  p ower (-48v) from the SREPN to the TN2301 
    has failed .
    DATA (yellow) On stead y Data p assing throug h the TN2301 to/from the A-c arrier 
    EI  b o a r d  i n t h e EPN .
    Continued on next page 
    						
    							DEFINITY® Enterprise Communications Server Release 7 Installation and 
    Maintenance for Survivable Remote EPN  555-233-102  Issue 2
    June 1999
    SREPN Maintenance 
    2-13 Maintenance procedure 
    2
    Expansion Interface (TN570C) LED interpretation
    The Exp ansion Interfac e c irc uit p ac k has red , g reen, and  yellow LEDs. The red  
    and  g reen LEDs show the stand ard  c ond itions:
    nRed  ind ic ates an alarm c ond ition
    nGreen ind ic ates maintenanc e testing  in p rog ress
    The yellow LED is used  to p rovid e useful visual status information:
    nAc tive EI c irc uit p ac ks:
    — Have their yellow LED on solid  (for an inter-EPN EI in a 
    d irec t-c onnec t system)
    — Blink a p attern of 2 sec ond s on and  200 ms off.
    nThe stand b y PNC EI c irc uit p ac ks should  have their yellow LEDs off.
    NOTE:
    Another way to d etermine whic h PNC (and  therefore, whic h EI in a p ort 
    network) is ac tive and  whic h is stand b y, use the status port-network
     and 
    status PNC
     commands.
    See Tab le 2-6
     for the p ossib le EI yellow LED states.
    Off If off and  no servic e-affec ting  c ond itions are p resent, 
    Critic al Reliab ility B-c arrier links to the Release 7r are 
    up .
    AUTO (g reen) On stead y Indic ates that the TN2301 fac eplate switc h is in the 
    AUTO p osition. This is normal when in-service.
    SU RVI VE M OD E ON  
    (red )On stead y Survive mode ac tivated  either b y the Maintenanc e 
    c irc uit p ack c ontrol or the facep late switch is in the TEST 
    position.
    Table 2-5. TN2301 LED interpretation  — Continued
    LED (color) Condition Interpretation
    Continued on next page 
    						
    							DEFINITY® Enterprise Communications Server Release 7 Installation and 
    Maintenance for Survivable Remote EPN  555-233-102  Issue 2
    June 1999
    SREPN Maintenance 
    2-14 Maintenance procedure 
    2
    Table 2-6. Expansion Interface circuit pack 
    Yellow LED Flashing States 
    Condition LED On LED Off
    Fib er Out-of-Frame
    1
    1. This flashing  state c orresp onds to Error Codes 769 and  770 from the 
    Hard ware Error Log and ind icates a failure of Test #238. These error cod es 
    are usually ac c ompanied  by Error Cod e 1281 (no Exp ansion Interfac e or 
    Switc h Nod e Interface detected on op p osite end  of fib er). This condition may 
    b e c aused  by the ab sence of the neig hb or Exp ansion Interfac e or Switc h 
    Nod e Interface circuit p ac k, a b roken or missing  fiber, or a missing  lig htwave 
    transc eiver on either end p oint (Exp ansion Interfac e or Switch Nod e Interface 
    c irc uit p ac ks).
    When the SRP is in Survive mode, this flash rate at the Release 7r EI/SNI 
    circ uit pac k is normal, b ecause the TN2301 puts the fib er into loop around  
    b ac k to the Release 7r.
    0.1 second 0.1 sec ond
    In Frame-No Neig hb or
    2
    2. This c orresp ond s to Error Cod e 1281 from the Hard ware Error Log  and  
    ind ic ates a failure of Test #237. This condition is usually d ue to the failure of 
    this Expansion Interface c irc uit p ack or a failed  Exp ansion Interfac e or Switc h 
    Nod e Interfac e c irc uit p ac k c ounterp art.
    When the SRP is in Normal mode, the Expansion Interfac e c ircuit p ack’s 
    yellow LED flashes at this rate. THIS IS NORMAL. The links to its c ounterp art 
    in the R7r ARE down and  are not re-established  until the SRP g oes into 
    Sur v iv e m od e .
    0.5 second 0.5 sec ond
    Exp ansion Interface Active
    3
    3. This is the normal state for an Ac tive EPN Expansion Interfac e c ircuit p ac k 
    that is also the bus master (Exp ansion Arc hang el) in the EPN.2 sec ond s 0.2 sec ond
    Exp ansion Interface Active
    4
    4. This is the normal state for an Ac tive Exp ansion Interface circuit p ack that is 
    not the bus master (Exp ansion Arc hang el) for an EPN. This ap p lies only in 
    d irect-c onnec t config urations where the Exp ansion Interface circuit p ack in 
    an EPN is c onnec ted throug h a fib er link to an Exp ansion Interfac e circuit 
    p ac k in the other EPN. This state also ap p lies for an active Exp ansion 
    Interfac e c irc uit p ac k located  in the PPN.Solid  on Never off
    Exp ansion Interface Standb y
    5
    5. This is the normal state for a stand b y Expansion Interface c ircuit p ac k in the 
    PPN  a nd  EPN .
    Never on Solid off
    Continued on next page 
    						