Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Installation And Maintenance For Survivable Remote EPN Manual
Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Installation And Maintenance For Survivable Remote EPN Manual
Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Installation And Maintenance For Survivable Remote EPN Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
DEFINITY® Enterprise Communications Server Release 7 Installation and Maintenance for Survivable Remote EPN 555-233-102 Issue 2 June 1999 SREPN Installation 1-9 Install the SRP cabinet 1 3. Alig n the mounting holes in the g round p late with the four holes at the top of the c ab inet b elow the top c abinet. Slid e the mounting plate d own to seat on the sc rews. 4. Do not tig hten the sc rews yet. Install front ground plates (Systems with radiation shielding and earthquake protection) Use the front g round p late instead of the c ab inet c lip to attac h the c ab inets to eac h other. Use one front g round p late b etween two stac ked c ab inets. 1. At the front of the c ab inets, alig n the holes in the top of the front g round p late with the holes at the b ottom of the up per c ab inet, and insert the four sc rews. Do not tighten the sc rews yet. See Fi g u re 1 - 3 . 2. At the front of the c ab inets, alig n the holes in the b ottom of the front g round p late with the holes at the top of the lower c ab inet. Insert the four sup p lied #12-24 x 1/2-inc h (1.27 c m) thread -forming sc rews. 3. Tighten all screws securely.
DEFINITY® Enterprise Communications Server Release 7 Installation and Maintenance for Survivable Remote EPN 555-233-102 Issue 2 June 1999 SREPN Installation 1-10 Install the SRP cabinet 1 Figure 1-3. Rear ground plate and front plate or cabinet clip — side view Figure Notes 1. Front ground p late or c ab inet c lip 2. Rear g round plate 21 scdfgrpl KLC 011799
DEFINITY® Enterprise Communications Server Release 7 Installation and Maintenance for Survivable Remote EPN 555-233-102 Issue 2 June 1999 SREPN Installation 1-11 Install the SRP cabinet 1 Install cabinet clips (Systems without earthquake protection) A c ab inet c lip is required b etween eac h p air of stac ked c ab inets. At the front of the c ab inets, install a c ab inet c lip b etween eac h p air of c ab inets b y hooking the c lip into the slot of the up p er c ab inet and snap p ing the straig ht leg of the c lip into the slot on the lower c ab inet. See Fig ure 1-4 . Figure 1-4. Location of Cabinet Clips Figure Notes 1. Control Cab inet 2. Port Cab inet or Dup lic ated Control Cab inet 3. Port Cab inet4. SRP Cab inet 5. Cab inet Clip s
DEFINITY® Enterprise Communications Server Release 7 Installation and Maintenance for Survivable Remote EPN 555-233-102 Issue 2 June 1999 SREPN Installation 1-12 Connect cables to the SRP 1 Connect cables to the SRP The TN2301 survivab le remote switc h c irc uit p ac k is loc ated in slot 7 of the SRP c ab inet. Fib er op tic transc eivers are attac hed to the TN2301 c irc uit pac k. Fib er c ab les are c onnec ted from these transc eivers to the TX and RX c onnec tors on the rear of the c ab inet. NOTE: Always c onnec t a fib er c ab le from a TX c onnec tor to an RX c onnec tor and vic e versa. Do not c onnec t the c ab les to the EPN until you reac h the ‘‘ Re p la c e EPN c irc uit pac ks and make c able c onnec tions’’ sec tion. Dep end ing on the c ustomer’s c onfig uration, refer to one of the following sec tions for c onnec ting fib er c ab les to the SRP: nConnec t SRP fib er c ab les for stand ard /hig h reliab ility nConnec t SRP fib er c ab les for c ritic al reliab ility Connect SRP fiber cables for standard/high reliability 1. Connec t the eq uip ment as shown in Fi g u re 1 - 5. 2. Go to the ‘‘ Connec t the SRP and manag ement terminal’’ sec tion. Connect SRP fiber cables for critical reliability 1. Connec t the eq uip ment as shown in . 2. Go to the ‘‘ Connec t the SRP and manag ement terminal’’ sec tion.
DEFINITY® Enterprise Communications Server Release 7 Installation and Maintenance for Survivable Remote EPN 555-233-102 Issue 2 June 1999 SREPN Installation 1-13 Connect cables to the SRP 1 Figure 1-5. SRP fiber cables for standard/high reliability Figure Notes 1. To EPN A 2. To Port Network Connec tivity (PNC) A 3. Fib er op tic cab le4. SRP c ab inet 5. B25A 25-p air c ab le 6. Main Distribution Frame (MDF) cydfsdsa RPY 030998 TX EPN B EPN APPN B PPN A TX TX TX RX RX RX RX 3 3 2 1 5 4 6
DEFINITY® Enterprise Communications Server Release 7 Installation and Maintenance for Survivable Remote EPN 555-233-102 Issue 2 June 1999 SREPN Installation 1-14 Connect cables to the SRP 1 Figure 1-6. SRP fiber cables for critical reliability Figure Notes 1. To EPN B 2. To EPN A 3. To Port Network Connec tivity (PNC) B 4. To Port Network Connec tivity (PNC) A5. Fib er op tic cab le 6. SRP c ab inet 7. B25A 25-p air c ab le 8. Main Distribution Frame (MDF) TX EPN B EPN APPN B PPN A TX TX TX RX RX RX RX cydfaepn RPY 030998 12 34 5 5 5 5 6 7 8
DEFINITY® Enterprise Communications Server Release 7 Installation and Maintenance for Survivable Remote EPN 555-233-102 Issue 2 June 1999 SREPN Installation 1-15 Connect the SRP and management terminal 1 Connect the SRP and management terminal 1. See Fig ure 1-7 for SRP and manag ement terminal c onnec tions. Figure 1-7. SRP and management terminal connections Figure Notes 1. 14-inc h (35.5 c m) Y c able 2. B25A 25-p air cab le 3. To Main Distrib ution Frame (MDF) 4. RS-232 c ab le5. RS-232 null modem c able (to COM2 c onnec tor on management terminal) 6. 715 BCS-2 manag ement terminal 7. SRP c ab inet scdfsre2 RPY 030398 PI EITXEPN B EPN APPN B PPN ATX TX TX RX RX R X RXAU X DCE TERM S.R. SW IT CH 13 2 45 6 7
DEFINITY® Enterprise Communications Server Release 7 Installation and Maintenance for Survivable Remote EPN 555-233-102 Issue 2 June 1999 SREPN Installation 1-16 MDF connections 1 MDF connections 1. Punc h d own the following wires at the MDF. See Tab le 1-8. Table 1-8. 110 block cross-connect pins SRP AuxEPN Aux Color 1 1. The following wire c olors ap p ly to this tab le: W = White, BL = Blue, O = Orang e, G = Green, BR = Brown, BK = Blac k, V = Violet Cross- Connect Pin NumberCross- Connect Pin Number Color G-V 46 3 W-O SRP AuxSRP Switch ColorCross- Connect Pin NumberCross- Connect Pin Number Color W- O 3 4 6 G -V V- G 4 5 2 3 BK - O EPN AuxSRP Switch ColorCross- Connect Pin NumberCross- Connect Pin Number Color O-W 4 24 O-BK W- G 5 4 7 V-B R W-B R 7 4 8 BR-V V-BL 41 41 V-BL BL-V 42 42 BL-V V- G 4 5 4 3 V-O G-V 46 44 O-V
DEFINITY® Enterprise Communications Server Release 7 Installation and Maintenance for Survivable Remote EPN 555-233-102 Issue 2 June 1999 SREPN Installation 1-17 Power up the SRP 1 Power up the SRP 1. Set the TN2301 switc h to the Restore (RSTR) p osition d uring the ad ministration to prevent the c ab inet from g oing into the survive mod e. 2. At the rear of the SRP, set the c irc uit b reaker to ON . This starts the system initialization and test. Administer the Release 7r and SRP !CAUTION: Do not save announc ements to the SRP translation c ard . NOTE: Ad ministering the SRP may take several hours. NOTE: This d oc umentation assumes that the Release 7r manag ement terminal and the SRP manag ement terminal are loc ated in the same room. If this is not the c ase, make the ap p rop riate p rovisions. NOTE: An “ init” log in is req uired to p erform the following . Contac t the reg ional CSA (Customer Software Assoc iate) to assig n the Offer Categ ory option. Maintenanc e c ap abilities to initialize the system and ac c ess to either an internal or external mod em are the only c ommand op tions availab le until the Offer Categ ory op tion is set. NOTE: Not all ad ministration should b e c op ied direc tly (Examp le: c overag e paths, abbreviated dial lists, and bridged appearances). These ad ministration items may not b e valid if the SRP g oes into survival mode. NOTE: The following are examples of the typ es of ad ministration that need to b e ad d ed to the SRP. Sinc e c onfig urations and ad ministration varies for every switc h, it is not p ossib le to list all of the ad ministration that is needed for your SRP.
DEFINITY® Enterprise Communications Server Release 7 Installation and Maintenance for Survivable Remote EPN 555-233-102 Issue 2 June 1999 SREPN Installation 1-18 Administer the Release 7r and SRP 1 Administration of the Release 7r 1. Type display system-parameters maintenance and p ress En te r. Rec ord the p rod uc t ID for later use. 2. Choose an op tion and enter the c ommand on the Release 7r manag ement terminal: nIf c hang ing an existing EPN to an SREPN, typ e change cabinet (number is the c abinet number of the SREPN) and p ress En t e r. nIf ad ding a new EPN as an SREPN, type add cabinet (next g ives you the next availab le numb er). 3. In the Survivable Remote EPN? field , typ e y . 4. In the Survivable Remote Processor ID field , ad d the p rod uc t ID of the SRP. The p rod uc t ID is loc ated on the d isp lay system-p arameters maintenanc e sc reen on the SRP manag ement terminal. 5. Press En t e r. Administration of the SRP The first step is to administer the hard ware. The next step is to ad minister the software. Finally, ad minister any ind ivid ual features. Administering the hardware 1. On the Release 7r manag ement terminal, typ e list cabinet and press En t e r. Id entify the p ort network of the SREPN. See Fig ure 1-8 . Figure 1-8. List cabinet screen list cabinet SPE B CABINET REPORT No. Type Layout Room Floor Building A B C D E 1 PPN 5-car CS_1 1 ABC_DE PN 01 PN 01 PN 01 SN 01 SN 01 2 EPN 5-car CS_1 1 ABC_DE PN 04 PN 04 PN 04 PN 16 PN 16 3 sEPN 5-car CS_1 1 ABC_DE PN 05 PN 05 PN 05 SN 44 SN 44 4 EPN 5-car B-32 B VWX_YZ PN 06 PN 06 PN 06 SN 07 SN 07 5 EPN 5-car 2-12 2 MNO_PQ PN 08 PN 08 PN 08 SN 09 SN 09 6 EPN 5-car E-51 1 VWX_YZ PN 10 PN 10 PN 10 SN 11 SN 11