Home > Lucent Technologies > Communications System > Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Administration For Network Connectivity Manual

Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Administration For Network Connectivity Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Administration For Network Connectivity Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 524
    							IP Trunk Administration 
    421
    Administration for Network Connectivity
    555-233-504— Issue 1 — April 2000 CID: 77730
    F  IP Trunk Installation and
    Administration
    DEFINITY administration procedures
    The following procedures must be performed on the DEFINITY ECS to administer IP 
    Trunks.
    !CAUTION:
    The fields described in the following procedure must be completed as shown. 
    If they are not, the IP Trunk service may not work properly. Other fields may 
    be completed as appropriate for your system.
    DS1 Circuit PackAs an example, administer the IP Trunk circuit pack at 01A09 to emulate T1 service 
    for 24 channels. (See the table below for the settings to emulate E1 service for 30 
    channels). Note that you are administering the IP Trunk circuit pack in this procedure, 
    not an actual DS1 circuit pack.
    1  Ty p e add ds1 01A09 and press ENTER.
    01A09 is the address of the IP Trunk circuit pack. The DS1 Circuit Pack screen 
    appears.
    2  Enter the field values as shown in the screen diagram above.
    3  Press ENTER to save your changes.
    add ds1 1a09
                                  DS1 CIRCUIT PACK
                Location: 01A09                           Name: T1-RB to ITS1
                Bit Rate: 1.544                    Line Coding: ami-zcs
       Line Compensation: 3                       Framing Mode: d4
          Signaling Mode: robbed-bit
    Interface Companding: mulaw
               Idle Code: 11111111
     MAINTENANCE PARAMETERS
          Slip Detection? n 
    						
    							IP Trunk Administration F  IP Trunk Installation and
    Administration
    Administration for Network Connectivity
    CID: 77730 555-233-504 — Issue 1 — April 2000
    422
    More information
    The table below summarizes field settings on the DS1 screen for the T1 and E1 
    service emulated for IP Trunk service.
    Creating an IP trunk 
    groupUse this procedure to add a trunk group for IP trunks. You can administer multiple 
    trunk groups on one IP Trunk circuit pack. Each trunk group is assigned to virtual 
    ports, or channels, on the IP Trunk circuit pack, and your routing plan directs calls to 
    certain trunks.
    !CAUTION:
    The fields described in the following procedure must be completed as shown. 
    If they are not, the IP Trunk service may not work properly. Other fields may 
    be completed as appropriate for your system.
    As an example, add trunk group 5 and assign 12 ports for a virtual connection to the 
    IP Trunk circuit pack:
    1  Ty p e  add trunk-group 5 and press ENTER.
    The Trunk Group screen appears. Field Setting for T1 Setting for E1
    Bit Rate1.544 2.048
    Line Codingami-zcs
    ami-basic or hdb3
    Line Compensation33
    Framing Moded4
    Signaling Moderobbed-bit cas
    Interface Compandingmulaw mulaw
    Idle Code 11111111 11111111
    Slip Detectionnn
    Near End CSU typeother
    Interconnectpbx
    Country Protocol1 
    						
    							IP Trunk Administration 
    423
    Administration for Network Connectivity
    555-233-504— Issue 1 — April 2000 CID: 77730
    F  IP Trunk Installation and
    Administration
    Note:Depending on how the routing between sites is administered, inserting 
    digits may be required. The example shows a 9 being inserted in front 
    of any digits received from the IP Trunk. In most DEFINITY ECS 
    switches, this is the access code for ARS and will allow the digits 
    received on the trunk to be analyzed and rerouted based on ARS analysis 
    table entries.
    2  Enter the field values as shown in the screen diagram above.
    Note:All IP trunk groups are administered as DS1 tie trunks (Group Type = 
    tie).
    3  Move to the Trunk Features page and type n in the Maintenance Tests field.
    4  In the Suppress # Outpulsing field, type y.
    Note:You may need to fill in other fields for your system.
    5  Move to the Group Member Assignments page and add the ports (channels) 
    you’ve purchased.
    You’re assigning virtual ports, or channels, to the IP Trunk circuit pack. Each 
    channel can carry one call at a time. The number of ports you can use is limited to 
    the maximum number specified in your license.
     TRUNK GROUP
     Group Number: 5__ Group Type: tie           CDR Reports: y
       Group Name: IP Trunk 01A09 COR: 85_  TN: 1__      TAC: 105_
        Direction: two-way_       Outgoing Display? y Trunk Signaling Type: ____
      Dial Access? n                Busy Threshold: 99_         Night Service: ____
     Queue Length: 0__                                   Incoming Destination: ____
        Comm Type: voice                 Auth Code? n
     TRUNK PARAMETERS
        Trunk Type (in/out): wink/wink___     Incoming Rotary Timeout(sec): 5_
         Outgoing Dial Type: tone_____                 Incoming Dial Type: tone____
    Wink Timer (msec): 300 Disconnect Timing(msec): 500_
            Digit Treatment: insertion  Digits: 9___
                                                         Sig Bit Inversion: none
    Connected to Toll? n STT Loss: low DTT to DCO Loss: normal
    Incoming Dial Tone? y
      Disconnect Supervision - In? y  Out? n
      Answer Supervision Timeout: 0__           Receive Answer Supervision? y 
    						
    							IP Trunk Administration F  IP Trunk Installation and
    Administration
    Administration for Network Connectivity
    CID: 77730 555-233-504 — Issue 1 — April 2000
    424
    6  Press ENTER to save your changes.
    Administer AAR/ARSYou can use Automatic Alternate Routing (AAR) and Automatic Route Selection 
    (ARS) to route calls over an IP trunk group just like any other trunk group. Unlike 
    other trunk groups, however, you must administer both the DEFINITY ECS switch 
    software and Configuration Manager to route calls over IP trunks. DEFINITY ECS 
    uses the dialed digit string to select a route pattern — and thus a trunk group — for 
    each call. The IP Trunk software matches each trunk line or each dialed string to a 
    specific IP address.
    The following administration needs to be performed on both the origin and 
    destination switches — if you can’t administer the remote switch, coordinate this 
    work with the administrator at the other site. The following general instructions 
    assume that you know how to use Automatic Alternate Routing (AAR) and 
    Automatic Route Selection (ARS) to route conventional calls.
    To administer IP call routing on DEFINITY ECS:
    1  Administer the AAR and ARS Digit Analysis Table on DEFINITY ECS with the 
    information you entered in the Switch Admin tables on the worksheet.
    2  After you’ve assigned a route pattern in the AAR or ARS Digit Analysis Table, 
    add the IP trunk group to that route pattern if you haven’t already done so
    3  Make the IP trunk group the first preference in the route pattern and perform any 
    other administration required on the Route Pattern screen.
    Note:If you want to route calls over the normal telephone network when 
    transmission quality over the IP network is unacceptable, assign one or 
    more conventional trunk groups to the route pattern as backups.
    DEFINITY ECS will route appropriate calls to the IP trunk group. Now you need to 
    administer Configuration Manager to route outgoing and incoming calls 
    appropriately.
    TRUNK GROUP
    Administered Members(min/max): 1/12
    Total Administered Members: 12
    GROUP MEMBER ASSIGNMENTS
    Port Code Sfx Name Night Mode Type Ans Delay
    1: 01A0901 ___________ ___________  _____  ________ _______ ____
    2: 01A0902 ___________ ___________  _____  ________ _______ ____
    3: 01A0903 ___________ ___________  _____  ________ _______ ____
    4: 01A0904 ___________ ___________  _____  ________ _______ ____
    5: 01A0905 ___________ ___________  _____  ________ _______ ____
    6: 01A0906 ___________ ___________  _____  ________ _______ ____
    7: 01A0907 ___________ ___________  _____  ________ _______ ____
    8: 01A0908 ___________ ___________  _____  ________ _______ ____
    9: 01A0909 ___________ ___________  _____  ________ _______ ____
    10: 01A0910 ___________ ___________  _____  ________ _______ ____
    11: 01A0911 ___________ ___________  _____  ________ _______ ____
    12: 01A0912 ___________ ___________  _____  ________ _______ ____
    13: _______  ___________ ___________  _____  ________ _______ ____
    14: _______  ___________ ___________  _____  ________ _______ ____
    15: _______  ___________ ___________  _____  ________ _______ ____ 
    						
    							IP Trunk Administration 
    425
    Administration for Network Connectivity
    555-233-504— Issue 1 — April 2000 CID: 77730
    F  IP Trunk Installation and
    Administration
    Backing up configuration manager
    Lucent recommends you perform a backup to the Personal Computer Memory Card 
    International Association (PCMCIA) flash disk whenever you make a change in the 
    configuration manager. Keep the flash disk in a safe place so you can use the backup 
    information if your MAPD circuit pack fails or if you want to restore to a previous 
    known state.
    Before you beginBe sure your backup PCMCIA flash disk is inserted in the MAPD circuit pack.
    InstructionsTo perform a backup, begin at the Windows NT desktop:
    1  Double-click the IP Trunk Backup Restore icon.
    The IP Trunk Backup/Restore Utility screen appears.
    2  In the IP Trunk Backup/Restore Utility dialog screen, click Files, Backup.
    The IP trunk Backup screen appears.
    3  In the IP Trunk Backup screen, click on the BACKUP button.
    4  Remove the flash disk and store in a safe place.
    Restoring IP trunk
    Before you start 1  Remove the defective MAPD circuit pack from the switch.
    2  Install the replacement MAPD circuit pack in the switch.
    3  Insert the backup PCMCIA flash disk into the MAPD circuit pack. 
    InstructionsTo perform a restore, begin at the Windows NT desktop:
    1  Double-click the IP Trunk Backup Restore icon.
    The IP Trunk Backup/Restore Utility screen appears.
    2  In the IP Trunk Backup/Restore Utility dialog screen, click Files, Restore.
    The IP trunk Backup screen appears.
    3  In the IP Trunk Backup screen, click on the RESTORE button. 
    						
    							IP Trunk Administration F  IP Trunk Installation and
    Administration
    Administration for Network Connectivity
    CID: 77730 555-233-504 — Issue 1 — April 2000
    426
    Confirming the number of available ports
    To confirm that all ports allowed under your license are available, start at the 
    Windows NT desktop:
    1  Double-click the Configuration Manager icon.
    IP Trunk Configuration Manager appears.
    2  Click the Telephony tab.
    The Telephony property page appears.
    3  Click Show All Ports.
    Verify that the number of enabled port matches the maximum your license allows. 
    If not, contact your Lucent representative.
    4  Click OK to close Configuration Manager.
    NT administration procedures
    The following procedures must be performed on the NT server to administer IP Trunks.
    Administer call routing 
    parameters on 
    Configuration ManagerOutgoing calls
    To administer routing for outgoing (originating) calls, start at the Windows NT 
    desktop:
    1  Double-click the Configuration Manager icon.
    IP Trunk Configuration Manager appears.
    2  Click the Telephony tab.
    The Telephony property page appears.
    3  In the Maximum Digits to be collected box, type the number of digits that the 
    switch will forward to the IP Trunk software.
    The Maximum Digits to be collected field entry will be determined by the type of 
    dialing, or types of dialing that will be performed using IP Trunking. Refer to the 
    Dial/Routing Plan Worksheets, or if extension dialing is used, this field would be 
    the extension length in the DEFINITY private network.
    !CAUTION:
    Set this field no higher than the maximum length of the digit string the switch 
    sends. Otherwise, the IP Trunk application waits several seconds for 
    additional digits and users experience delays.
    4  Click the Dial/Routing Plan tab.  
    						
    							IP Trunk Administration 
    427
    Administration for Network Connectivity
    555-233-504— Issue 1 — April 2000 CID: 77730
    F  IP Trunk Installation and
    Administration
    The Dial/Routing Plan window appears.
    5  In the Machine Name list, select the machine name of the local IP Trunk server.
    6  Select Originating and click Add (under Routing Info). The Add Originating 
    Entry dialog box appears. 
    none
    1
    01 
    						
    							IP Trunk Administration F  IP Trunk Installation and
    Administration
    Administration for Network Connectivity
    CID: 77730 555-233-504 — Issue 1 — April 2000
    428
    7  In the Add Originating Entry dialog box, you enter information that routes the call 
    data between originating and terminating locations. You need to enter information 
    that allows the IP Trunk to route calls based on dialed digits or on the line (port) 
    that a call arrives on.
    Note:It is not possible to mix dialing strategies in the IP Trunk software. Once 
    line numbers are used to route calls, line numbers must be used on ALL 
    entries in a routing table.
    Routing information entered will be based on information that has been entered 
    on the Dial/Routing Plan Worksheets, or on information collected based on the 
    Procedures for Extension Dialing Between Sites.
    Routing based on Dialed String
    If routing will be based on dialed string, enter any in the Line Number field, then 
    enter the information from the worksheets or a unique identifier for an extension 
    range from the Procedures for Extension Dialing.
    Routing based on Line Numbers
    If routing will be based on line numbers that are dedicated to a specific location, 
    you need to make sure that the same line number is used on both the originating 
    and destination switches. This is done by prepending a string of digits unique to a 
    line and associating it with that line number at both the originating and 
    terminating IP Trunks. This code will be discarded at the terminating end.
    For example, in the display above, the code number 01 is entered in the Replace 
    Digits field as a unique digit string that will be associated with line number 1. If 
    none is entered in the Search Digits field, no digits will be searched for. We don’t 
    need to search for dialed digits because the line numbers, which are associated 
    with port numbers on the circuit pack, are dedicated in a DEFINITY trunk group 
    to a particular location. Any digits received on these lines will always be routed to 
    the same location. The only requirement is to prepend digits in the replace digits 
    field to ensure that a call placed on a line (port) at the originating end can be 
    terminated on the same line at the destination end. The digits prepended at the 
    originating end and searched for at the terminating end must be the same.
    Note:Any digits searched for must also be replaced if they are used to complete 
    the routing of a call. If digit substitution will be needed, it may be 
    necessary to put a digit string in the Search Digits field, and substitute 
    those with new digits in the Replace Digits field.
    8  For Entry Type, enter accept to allow incoming calls.
    9  In the Search Digits field, type the digits entered in the Originating Search string 
    box for this site in the Dial/Routing Plan Worksheets, or follow the Procedures for 
    Extension Dialing Between Sites.
    10  In the Replace Digits field, type the digits entered in the Originating Replace 
    string box for this site in the Dial/Routing Plan Worksheets, or follow the 
    Procedures for Extension Dialing Between Sites.
    11  In the Destination Type field, select the appropriate value for the remote switch.
    Select ITS R1.2 if the other switch uses IP Trunk. 
    						
    							IP Trunk Administration 
    429
    Administration for Network Connectivity
    555-233-504— Issue 1 — April 2000 CID: 77730
    F  IP Trunk Installation and
    Administration
    12  In the Destination Address (IP) field, type the Internet Protocol (IP) address of the 
    destination IP Trunk on the remote switch.
    13  In the Port field, type the port number to be used for this connection. The port 
    number used in all IP Trunk servers is “5000”.
    14  Click OK.
    The Add Originating Entry dialog box closes and the Dial/Routing Plan dialog 
    box appears showing the information you entered.
    Repeat the above steps for each originating entry (line or dialed string) specified in 
    the Dial/Routing Plan Worksheets and/or the Procedures for Extension Dialing 
    Between Sites.
    Incoming calls
    To administer routing for incoming (terminating) calls, start at the Windows NT 
    desktop:
    1  Double-click the Configuration Manager icon. The Configuration Manager 
    appears.
    2  Click the Dial/Routing Plan tab.
    The Dial/Routing Plan dialog box appears. 
    						
    							IP Trunk Administration F  IP Trunk Installation and
    Administration
    Administration for Network Connectivity
    CID: 77730 555-233-504 — Issue 1 — April 2000
    430
    3  In the Machine Name box, select the local machine name for the local IP Trunk 
    server.
    4  Select Te r m i n a t i n g
    5  Click Add (under Routing Info). 
    The Add Terminating Entry dialog box appears.
    6  In the Add Terminating Entry dialog box, you enter information that routes the 
    incoming call to a terminating location. You need to enter information that allows 
    the IP Trunk to route calls based on dialed digits or on the line (port) that a call 
    arrives on.
    Note:It is not possible to mix dialing strategies in the IP Trunk software. Once 
    line numbers are used to route calls, line numbers must be used on ALL 
    entries in a routing table.
    Routing information entered will be based on information that has been entered 
    on the Dial/Routing Plan Worksheets, or on information collected based on the 
    Procedures for Extension Dialing Between Sites.
    Routing based on Dialed String
    If routing will be based on dialed string, enter any in the Line Number field, then 
    enter the information from the worksheets or a unique identifier for an extension 
    range from the Procedures for Extension Dialing.
    Routing based on Line Numbers
    If routing will be based on line numbers that are dedicated to a specific location, 
    you need to make sure that the same line number is used on both the originating 
    and destination switches. This is done by prepending a string of digits unique to a 
    line and associating it with that line number at both the originating and 
    terminating IP Trunks. This code will be discarded at the terminating end. 
    						
    All Lucent Technologies manuals Comments (0)