    Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Administration For Network Connectivity Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 524
    							Configuration 4:  R8csi  R8si Gateway 
     R8csi 
    131
    Administration for Network Connectivity
    555-233-504— Issue 1 — April 2000 CID: 77730
    3  C-LAN Administration
    > Submit the screen
    End
    Destination 
    NodeName of the far-end node for this channel. This must be a name 
    entered on the Node Names screen. For ppp connections, it must 
    match the Destination Node Name entered on the ppp Data 
    Module screen.
    Destination 
    PortA value of 0 allows any available interface channel on the 
    destination node to be used for this connection. The Interface 
    Channel number for this connection on the Switch-2 Processor 
    Channel screen must also be set to 0.
    Session - 
    LocalFor each connection, the Local Session number on this switch 
    must equal the Remote Session number on the remote switch and 
    vice versa. Session - 
    Remote
    Mach ID Leave blank for gateway applications. Field Conditions/Comments
    3 of 3 
    						
    							Configuration 4:  R8csi  R8si Gateway 
     R8csi 3  C-LAN Administration
    Administration for Network Connectivity
    CID: 77730 555-233-504 — Issue 1 — April 2000
    132
    Switch 1 Task — Assign Signaling Group and administered NCA TSC
    This task assigns a signaling group and an administered NCA TSC for the ISDN 
    connection to Switch 2.
    Begin
    Steps>
    > Open the Signaling Groups form — enter ch sig n
    > Enter values
    > Press the Next Page key
    change signaling-group next
                                                          Page 1 of 5
                               SIGNALING GROUP
    Group Number: 1
        
    Associated Signaling? y            Max number of NCA TSC: 5_
                           Primary D-Channel: 01b0924       Max number of CA TSC: 23                        Trunk Group for NCA TSC: 12       Trunk Group for Channel Selection: 12__
              Supplementary Service Protocol: a__
    Field Conditions/Comments
    Associated Signaling? Specifies Facility-Associated Signaling (FAS) — the 
    D-channel carries signaling only for the B-channels on 
    the same DS1 interface. 
    Primary D-Channel Specifies D-Channel signaling on port 24 of the DS1 
    circuit pack located at 01b09.
    Max number of NCA 
    TSCMaximum number of simultaneous non-call-associated 
    Temporary Signaling Connections. The TSCs carry 
    signaling for features not associated with a specific 
    call; for example, signals to turn on Leave Word 
    Calling.
    Max number of CA 
    TSCMaximum number of simultaneous call-associated 
    TSCs that can exist in the signaling group. Typically, 
    this is the number of ISDN-PRI trunk group members 
    controlled by this signaling group.
    Trunk Group for NCA 
    TSCThe ISDN-PRI trunk group number whose incoming 
    call-handling table will be used to handle incoming 
    NCA-TSCs through this signaling group. 
    Trunk Group for 
    Channel Selection
    Supplementary 
    Service Protocola indicates AT&T protocol; b indicates QSIG protocol. 
    						
    							Configuration 4:  R8csi  R8si Gateway 
     R8csi 
    133
    Administration for Network Connectivity
    555-233-504— Issue 1 — April 2000 CID: 77730
    3  C-LAN Administration
    > Enter values
                  Page 2 of 5
    ADMINISTERED NCA TSC ASSIGNMENT 
    Service/Feature: __________           As-needed Inactivity Time-out (min): __
     TSC   Local                                                   Mach.
    Index   Ext.  Enabled Established   Dest. Digits    Appl.   ID
      1:   2951_
         y     permanent  1701___________  dcs____  2_
      2:   2952_     y     permanent   1702___________  gateway   __
      3:   _____     _     _________   _______________  _______   __
      :  
     
    Field Conditions/Comments
    TSC Index 1: (for DCS connection to Switch 2)
    Local Ext. Extension number of the ISDN interface on the Switch-1DS1 
    circuit pack.
    Enabled
    y enables the administered NCA-TSC.
    Established Used to indicate the strategy for establishing this administered 
    NCA-TSC.
    permanent means that the administered NCA-TSC can be 
    established by either the near end or the far end.
    as-needed means the administered NCA-TSC will be established 
    the first time the administered NCA-TSC is needed; it can be set 
    up either by the near end or far end switch.
    Dest. Digits Extension number of the ISDN interface on the Switch-2 DS1 
    circuit pack.
    Appl. 1 TSC #1 carries the DCS signaling between node 1 and node 2.
    Mach ID 1 Destination is node 2.
    TSC Index 2: (for connection to Switch 2 for gateway to Switch 3)
    Local Ext. Extension number of the ISDN interface on the Switch-1 DS1 
    circuit pack.
    Enabled
    y enables the administered NCA-TSC.
    Established Used to indicate the strategy for establishing this administered 
    NCA-TSC.
    permanent means that the administered NCA-TSC can be 
    established by either the near end or the far end.
    as-needed means the administered NCA-TSC will be established 
    the first time the administered NCA-TSC is needed; it can be set 
    up either by the near end or far end switch.
    1 of 2 
    						
    							Configuration 4:  R8csi  R8si Gateway 
     R8csi 3  C-LAN Administration
    Administration for Network Connectivity
    CID: 77730 555-233-504 — Issue 1 — April 2000
    134
    > Submit the screen
    End
    Dest. Digits Extension number of the ISDN interface on the Switch-2 DS1 
    circuit pack.
    Appl. Specifies that TSC #2 will carry signaling that will be converted in 
    Switch-1 to another protocol (TCP/IP), which will then be 
    forwarded to Switch-3.
    Mach ID Leave blank for gateway Field Conditions/Comments
    2 of 2 
    						
    							Configuration 4:  R8csi  R8si Gateway 
     R8csi 
    135
    Administration for Network Connectivity
    555-233-504— Issue 1 — April 2000 CID: 77730
    3  C-LAN Administration
    Switch 1 Task — Assign ISDN-TSC Gateway
    This task assigns the ISDN TSC gateway channels needed for ISDN signaling 
    between node 1 and node2
    Begin
    Steps
    > Open the ISDN TSC Gateway Channel Assignment form — enter  ch isdn tsc
    > Enter values
    > Submit the screen
    End
    change isdn tsc-gateway                                         Page   1 of   2 
                          ISDN TSC GATEWAY CHANNEL ASSIGNMENT                       
       Sig   Admd NCA  Processor  Appli-     Sig   Admd NCA  Processor  Appli-
      Group  TSC Index   Channel   cation    Group  TSC Index   Channel   cation
     1: 1
    _ 2_14_ dcs_ 17: __  __ ___ ____ 
     2: __ _____ ____ 18: __  __ ___ ____ 
     3: __  __ ___ ____ 19: __  __ ___ ____ 
     4: __  __ ___ ____ 20: __  __ ___ ____ 
     5: __  __ ___ ____ 21: __  __ ___ ____ 
     6: __  __ ___ ____ 22: __  __ ___ ____ 
    :
    Field Conditions/Comments
    For Gateway Channel 1: (ISDN connection to Switch 2)
    Sig Group Signaling group number assigned on the Signaling Group 
    screen.
    Adm’d NCA 
    TSC IndexTSC Index assigned on page 2 of the Signaling Group screen 
    (Administered NCA TSC Assignment).
    Processor 
    ChannelThis is the Processor Channel number specified as a gateway 
    application on the Processor Channel Assignment screen.
    Application The application that this TSC is used for. 
    						
    							Configuration 4:  R8csi  R8si Gateway 
     R8csi 3  C-LAN Administration
    Administration for Network Connectivity
    CID: 77730 555-233-504 — Issue 1 — April 2000
    136
    Switch 2 Task — Assign Signaling Group and administered NCA TSC
    This task assigns a signaling group and an administered NCA TSC for the ISDN 
    connection to Switch 1.
    Begin
    Steps
    > Open the Signaling Groups form — enter ch sig n
    > Enter values
    change signaling-group next
                                                          Page 1 of 5
                               SIGNALING GROUP
    Group Number: 1
        
    Associated Signaling? y            Max number of NCA TSC: 5_
                           Primary D-Channel: 01a1024       Max number of CA TSC: 23                        Trunk Group for NCA TSC: 12       Trunk Group for Channel Selection: 21__
              Supplementary Service Protocol: a__
    Field Conditions/Comments
    Associated 
    Signaling?Specifies Facility-Associated Signaling (FAS) — the 
    D-channel carries signaling only for the B-channels on 
    the same DS1 interface. 
    Primary D-Channel Specifies D-Channel signaling on port 24 of the DS1 
    circuit pack located at 1a10.
    Max number of NCA 
    TSCMaximum number of simultaneous non-call-associated 
    Temporary Signaling Connections that can exist in the 
    signaling group. This number includes all NCA-TSCs 
    that are administered on this screen and those that 
    tandem through the switch in-route to another switch in 
    the network. The TSCs carry signaling for features not 
    associated with a specific call; for example, signals to 
    turn on Leave Word Calling.
    Max number of CA 
    TSCMaximum number of simultaneous call-associated TSCs 
    that can exist in the signaling group. Typically, this is the 
    number of ISDN-PRI trunk group members controlled by 
    this signaling group. If the connection is using the public 
    network (SDN), the total NCA + CA TSCs cannot 
    exceed the number ordered.
    Trunk Group for 
    NCA TSCThe trunk group used by the NCA-TSCs. 
    Trunk Group for 
    Channel SelectionLeave blank — this field is currently not used.
    Supplementary 
    Service Protocola indicates AT&T protocol; b indicates QSIG protocol. 
    						
    							Configuration 4:  R8csi  R8si Gateway 
     R8csi 
    137
    Administration for Network Connectivity
    555-233-504— Issue 1 — April 2000 CID: 77730
    3  C-LAN Administration
    > Press the Next Page key
    > Enter values
                  Page 2 of 5
    ADMINISTERED NCA TSC ASSIGNMENT 
    Service/Feature: __________           As-needed Inactivity Time-out (min): __
     TSC   Local                                                   Mach.
    Index   Ext.  Enabled Established   Dest. Digits    Appl.   ID
      1:   1701_
         y     permanent  2951___________  dcs____  1_
      2:   1702_     y     permanent  2952___________  dcs____  3_
      3:   _____     _     _________   _______________  _______   __
      :  
    Field Conditions/Comments
    TSC Index 1: (for DC S connection to Switch 1)
    Local Ext. Extension number of the ISDN interface for TSC #1 on the 
    Switch-2 DS1 circuit pack.
    Enabled
    y enables the administered NCA-TSC.
    Established Used to indicate the strategy for establishing this administered 
    NCA-TSC.
    permanent means that the administered NCA-TSC can be 
    established by either the near end or the far end.
    as-needed means the administered NCA-TSC will be 
    established the first time the administered NCA-TSC is needed; 
    it can be set up either by the near end or far end switch.
    Dest. Digits Extension number of the ISDN interface for TSC #1 on the 
    Switch-1 DS1 circuit pack.
    Appl. TSC #1 carries DCS signaling between node 2 and node 1.
    Mach ID Destination is node 1.
    TSC Index 2: (for DCS connection to Switch 1)
    Local Ext. Extension number of the ISDN interface for TSC #2 on the 
    Switch-2 DS1 circuit pack.
    Enabled
    y enables the administered NCA-TSC.
    Established Used to indicate the strategy for establishing this administered 
    NCA-TSC.
    permanent means that the administered NCA-TSC can be 
    established by either the near end or the far end.
    as-needed means the administered NCA-TSC will be 
    established the first time the administered NCA-TSC is needed; 
    it can be set up either by the near end or far end switch.
    1 of 2 
    						
    							Configuration 4:  R8csi  R8si Gateway 
     R8csi 3  C-LAN Administration
    Administration for Network Connectivity
    CID: 77730 555-233-504 — Issue 1 — April 2000
    138
    > Submit the screen
    End
    Dest. Digits Extension number of the ISDN interface for TSC #2on the 
    Switch-1 DS1 circuit pack.
    Appl. TSC #2 carries DCS signaling between Switch 2 and Switch 1. 
    As specified on the Switch-1 NCA TSC Assignment screen, 
    TSC #2 is administered as a gateway on Switch 1, where the 
    ISDN signals are converted to TCP/IP.
    Mach ID Destination is node 3. Field Conditions/Comments
    2 of 2 
    						
    							Configuration 4:  R8csi  R8si Gateway 
     R8csi 
    139
    Administration for Network Connectivity
    555-233-504— Issue 1 — April 2000 CID: 77730
    3  C-LAN Administration
    Switch 3 Task — Enable Bus Bridge Connectivity
    This task enables the bus bridge functionality on the C-LAN circuit pack to provide a 
    path between the packet bus and the processor.
    Note:Bus Bridge Connectivity is used on the csi model only. This task may 
    have been complete when the C-LAN circuit pack was installed.
    Begin
    Steps
    > Open the Maintenance-Related System Parameters form — enter  ch sys ma
    > Go to page 2 and skip to the Packet Intf2? field near the bottom of the screen
    > Enter values
    > Submit the screen
    End
    change system-parameters maintenance                            Page   2 of   3
     
                       MAINTENANCE-RELATED SYSTEM PARAMETERS           
    MINIMUM MAINTENANCE THRESHOLDS ( Before Notification )
            TTRs: 4        CPTRs: 1        Call Classifier Ports: 0  
            MMIs: 0          VCs: 0  
    TERMINATING TRUNK TRANSMISSION TEST ( Extension )
       Test Type 100:          Test Type 102:          Test Type 105:     
    ISDN MAINTENANCE
       ISDN-PRI Test Call Extension:         ISDN-BRI Service SPID:           
    DS1 MAINTENANCE
       DS0 Loop-Around Test Call Extension:      
    LOSS PLAN ( Leave Blank if no Extra Loss is Required )
       Minimum Number of Parties in a Conference Before Adding Extra Loss:  
    SPE OPTIONAL BOARDS
                         Packet Intf1? y     Packet Intf2? y
             Bus Bridge: 01a09__
    Inter-Board Link Timeslots  Pt0: 6 Pt1: 1 Pt2: 1
    Field Conditions/Comments
    Packet Intf2? Enables the bus bridge.
    Bus Bridge: Location of the C-LAN circuit pack. If the system has two
    C-LANs, only one is administered for bus bridge.
    Inter-Board 
    Link 
    Timeslots: 
    Pt0, Pt1, Pt2Specifies the bandwidth used on the 3 ports of the Inter-Board 
    Link. The total number of timeslots assigned cannot exceed 11. 
    Pt0 carries PPP traffic and can have 1–9 timeslots. Pt1 carries 
    maintenance messages and can have 1–3 timeslots. Pt2 carries 
    broadcast messages and can have 1–3 timeslots. 
    						
    							Configuration 4:  R8csi  R8si Gateway 
     R8csi 3  C-LAN Administration
    Administration for Network Connectivity
    CID: 77730 555-233-504 — Issue 1 — April 2000
    140
    Switch 3 Task — Assign Node Names
    This task assigns node names and IP addresses to each node in the network. This 
    screen is administered on Switch 3. A Node Names screen must be administered on 
    each switch in the network.
    The node names and IP addresses in any network should be assigned in a logical and 
    consistent manner from the point of view of the whole network. These names and 
    addresses should be assigned in the planning stages of the network and should be 
    available from the customer system administrator or from a Lucent representative.
    Note:Enter node names for Intuity AUDIX and MSA adjuncts on page 1. Enter 
    node names for switches, routers, and CMS starting on page 2.
    Begin
    Steps
    > Open Node Names form — enter  ch node-n
    > Go to page 2.
    > Enter values.
    > Submit the screen
    End
    change node-names
                                                                        Page 2 of 6
                                     NODE NAMES
       Name              IP Address          Name                IP Address
    default
    _________ 0__.0__.0__.0__ _______________ ___.___.___.___
    node-1  __  192.168.10_.101   _______________    ___.___.___.___
    node-3___        192.168.10_.103   _______________    ___.___.___.___
    ________________  ___.___.___.___    _______________    ___.___.___.___
    Field Conditions/Comments
    Name Enter unique node names for the following 2 nodes:
    •C-LAN PPP port on Switch 3
    •C-LAN PPP port on Switch 1.
    IP Address The unique IP addresses of the nodes named in the previous 
    field. 
    						