Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Administration For Network Connectivity Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
Configuration 3:R8si R8r Gateway R8si 101 Administration for Network Connectivity 555-233-504— Issue 1 — April 2000 CID: 77730 3 C-LAN Administration Switch 1 Task — Assign Node Names This task assigns node names and IP addresses to each node in the network. This screen is administered on Switch 1. A Node Names screen must be administered on each switch in the network. A node is defined as any of the following — a C-LAN port, a bridge or router, a CMS ethernet port, or an Intuity AUDIX or other MSA network interface card. The Audix and MSA node name and IP address must be entered on page 1 of the screen. The data for all other node types must be entered on pages 2–6. The node names and IP addresses in any network should be assigned in a logical and consistent manner from the point of view of the whole network. These names and addresses should be assigned in the planning stages of the network and should be available from the customer system administrator or from a Lucent representative. Note:Enter node names for Intuity AUDIX and MSA adjuncts on page 1. Enter node names for switches, routers, and CMS starting on page 2. Begin Steps > Open Node Names form — enter ch node-n > Go to page 2. > Enter values. > Submit the screen End change node-names Page 2 of 6 NODE NAMES Name IP Address Name IP Address default ________ 0__.0__.0__.0__ _______________ ___.___.___.___ node-1 __ 192.168.10_.1__ _______________ ___.___.___.___ node-3___ 192.168.10_.3__ _______________ ___.___.___.___ _____________ _ ___.___.___.___ _______________ ___.___.___.___ Field Conditions/Comments Name Enter unique node names for the following 2 nodes: •C-LAN Ethernet port on Switch 1 •C-LAN Ethernet port on Switch 3. IP Address The unique IP addresses of the nodes named in the previous field.
Configuration 3:R8si R8r Gateway R8si 3 C-LAN Administration Administration for Network Connectivity CID: 77730 555-233-504 — Issue 1 — April 2000 102 Switch 1 Task — Assign pdm Data Module This task administers a pdm data module for the connection between the PGATE board and the DS1 board for the connection to node-2. The data module associates a link number with a port address and extension number for the PGATE port used for this connection. Begin Steps > Open the Data Module form — enter a da n > Enter values add data-module next Page 1 of 2 Data Module Data Extension: 30 Name: pdm on port 1c0102BCC: Type: pdm _________ COS: 1 Remote Loop-Around Test? nPort: 01C0102 COR: 1 Secondary data module? nITC: restricted__ TN: 1 Connected to: dte ABBREVIATED DIALING List1: SPECIAL DIALING OPTION: ASSIGNED MEMBER (Station with a data extension button for this data module) Ext Name 1: 1002 station name Field Conditions/Comments Type: This indicates the data-module type for this connection. Port: This example means that the PGATE circuit pack is in slot 01c01 and link 5 uses port 02. ITC: Enter restricted. (unrestricted is used only for wideband transmission.) Name: Information-only; appears in list generated by the “list data module” command. COS: The values for these fields will be specified by the system administrator. COR: TN: Remote Loop-Around Test?Set to n unless testing. 1 of 2
Configuration 3:R8si R8r Gateway R8si 103 Administration for Network Connectivity 555-233-504— Issue 1 — April 2000 CID: 77730 3 C-LAN Administration Secondary data modules?Enter n. Connected To Enter dte. Keep the default values for the rest of the fields. Field Conditions/Comments 2 of 2
Configuration 3:R8si R8r Gateway R8si 3 C-LAN Administration Administration for Network Connectivity CID: 77730 555-233-504 — Issue 1 — April 2000 104 Switch 1 Task — Assign Link via x.25 Data Module to Switch 2 This task administers an x.25 data module for the connection to node 2. The data module associates a link number with a port address and extension number for the PGATE port used for this connection. Begin Steps > If a PGATE circuit pack is not already administered in slot 1c01, insert the circuit pack in the slot and enter add pgate 1c01, then fill in the PGATE screen. >Open the Data Module form — enter a da n > Enter values add data-module next Page 1 of 2 DATA MODULE Data Extension: 2102 Name: x.25 on link 5 to sw-2 Type: x.25 COS: 1Remote Loop-Around Test? n Port: 01C0102 COR: 1 Destination Number: external Baud Rate: 9600___ TN: 1 Establish Connection? y Endpoint Type: adjunct DTE/DCE: dteConnected Data Module: 4121_ Link: 5_ Enable Link? nError Logging? n Permanent Virtual Circuit? y Highest PVC Logical Channel: 64 Switched Virtual Circuit? n Field Conditions/Comments Type: This indicates the data-module type for this connection. Port: This example means that the PGATE circuit pack is in slot 01c01 and link 5 uses port 02. Baud Rate: Set to 9600 for DCS connections to vs or si models, or to an r model with an external 9600 baud data line. Set to switched for r-to-r connections with common channel signaling on DS1 trunks. Set to 9600 for connections to Intuity AUDIX. Set to either 9600 or 19200 for CMS, depending on the physical connectivity. Endpoint Type: For DCS, CMS, or Intuity AUDIX, set this field to adjunct. Link: The link number must be in the range 1 – 33 (for R8r), not previously assigned on this switch. 1 of 2
Configuration 3:R8si R8r Gateway R8si 105 Administration for Network Connectivity 555-233-504— Issue 1 — April 2000 CID: 77730 3 C-LAN Administration > Submit the screen End Name:Information-only; appears in list generated by the “list data module” command. COS: The values for these fields will be specified by the system administrator. COR: TN: DTE/DCE: The DTE/DCE assignments must be opposites on the two ends of the connection. Use dce for node 2. Enable Link? Set to y after the processor channels have been assigned. Remote Loop-Around Test?Set to n unless testing. Destination Number: external is used when connecting an r-model to an si-model. For an r-to-r connection, enter the TAC+extension. Establish Connection?y means that this switch will be responsible for the call setup for this connection. Enter n when administering the data module for Switch 2. Connected Data ModuleExtension of node-2 data module. Error Logging? Set to n for normal operations. Set to y for testing — logs all data module errors. Permanent Virtual Circuit?Always y for DCS, CMS, and Intuity AUDIX. Switched Virtual Circuit?Always n for DCS, CMS, and Intuity AUDIX. Highest PVC Logical Channel:Set to 64 (the default) for normal operations. Field Conditions/Comments 2 of 2
Configuration 3:R8si R8r Gateway R8si 3 C-LAN Administration Administration for Network Connectivity CID: 77730 555-233-504 — Issue 1 — April 2000 106 Switch 1 Task — Assign IP Interfaces The IP interface for each C-LAN board on the switch must be defined on the IP Interfaces form. Each DEFINITY switch in an IP network has one IP Interfaces form. Begin Steps > Open IP Interfaces form — enter ch ip-i > Enter values change ip-interfaces Page 1 of 2 IP Interfaces Inter-region IP connectivity allowed? n Enable Net Eth Pt Type Slot Code Sfx Node Name Subnet Mask Gateway Addr Rgn y C-LAN 01b01 TN799 B node-1 255.255.255.0 .._. 1 n 255.255.255.0 n 255.255.255.0 n 255.255.255.0 Field Conditions/Comments Inter-region IP connectivity allowed?Enter y to allow IP endpoints (phones and trunks) to use MedPro resources administered in regions that are different from the endpoints’ regions. Enable Eth Pt The Ethernet port must be enabled (y) before it can be used. The port must be disabled (n) before changes can be made to its attributes on this screen. Type Enter c-lan or medpro. Slot Enter the slot location for the circuit pack. Code Display only. This field is automatically populated with TN799 for C-LAN or TN802 for MedPro. Sfx Display only. This field is automatically populated with B for the TN802 and TN799. Node name Enter the unique node name for the IP interface. The node name here must already be administered on the Node Names screen 1 of 2
Configuration 3:R8si R8r Gateway R8si 107 Administration for Network Connectivity 555-233-504— Issue 1 — April 2000 CID: 77730 3 C-LAN Administration Subnet Mask Enter the subnet mask associated with the IP address for this IP interface. (The IP address is associated with the node name on the Node Names screen). In this example, leave the default subnet mask, 255.255.255.0, which indicates no subnetting for a Class C IP address. See the discussion of subnetting, Subnetting (page 16), in Chapter 1 and Configuration 1: R8r R8si (page 60) in this chapter for details about subnet masks. Gateway Addr Leave blank for this configuration. The only connection to this IP interface is node-3 on Switch 3. Node-3 is on the same subnetwork as this IP interface, so no gateway is needed. In general, for connectivity to other (sub)networks, enter the address of a network node that will serve as the default gateway to the other (sub)networks. Net Rgn Enter the region number for this IP interface. Field Conditions/Comments 2 of 2
Configuration 3:R8si R8r Gateway R8si 3 C-LAN Administration Administration for Network Connectivity CID: 77730 555-233-504 — Issue 1 — April 2000 108 Switch 1 Task — Assign Link via ethernet Data Module to the LAN This task administers an ethernet data module for ethernet connections. The data module associates a link number with a port address, extension number, and node name for the C-LAN port used for this connection. Begin Steps > Open Data Module form — enter a da n > Enter values. > Submit the screen End add data module next Page 1 of x DATA MODULE Data Extension: 3391 Name: ethernet on link 3 BCC: 2 Type: ethernet Port: 01b0117 Link: 3 Network uses 1’s for broadcast addresses? y Field Conditions/Comments Type: This indicates the data-module type for this connection. Port: In this example, the C-LAN circuit pack is in slot 01b01; the ethernet connection is through port 17. Link:The link number must be in the range 1 – 33 (for R8r). Name: Information-only; appears in list generated by the “list data module” command. Network uses 1’s for broadcast addresses?Leave the default (y) if the private network contains only DEFINITY switches and adjuncts. Set to n only if the network includes non-DEFINITY switches that use the 0’s method of forming broadcast addresses. See Appendix A, “Data Module - type ethernet” for more information about this field.
Configuration 3:R8si R8r Gateway R8si 109 Administration for Network Connectivity 555-233-504— Issue 1 — April 2000 CID: 77730 3 C-LAN Administration Switch 1 Task — Assign Processor Channels This task associates data links (hardware) with processor channels (software) on the node-1 switch. Begin Steps> > Open Processor Channel Assignment form — enter ch com p Note:The Processor Channel number, the Interface Channel number, and the Local and Remote Session numbers do not need to be the same number but they should be made the same whenever possible to simplify network “bookkeeping” and diagnostics. > Enter values change communications-interface processor-channels Page 1 of X PROCESSOR CHANNEL ASSIGNMENT Proc Gtwy Interface Destination Session Mach Chan Enable Appl. To Mode Link/Chan Node Port Local/Remote ID 1: n ________ _ __ _____ _________ 0____ ___ ___ __ 2: n ________ _ __ _____ _________ 0____ ___ ___ __ : 21: y dcs_____ _ 5_ 21___ _________ 0____ 21_ 21_ 2_ : 23: y gtwy-tcp 32__ 5_ 23___ _________ 0____ 23_ 23_ __ : 31: y dcs_____ s 3_ 5003 node-3___ 0_ 31_ 31_ 3_ : 32: y gtwy-tcp23_s 3_ 6002 node-3___ 0_ 32_ 32_ __ : 256: n ________ _ __ _____ _________ 0____ ___ ___ __ Field Conditions/Comments Processor Channel 21: (X.25 connection to Switch 2) Enable Set to y. Appl. Set to dcs for DCS signaling. Mode Used for TCP/IP connections only. Interface Link This must match the link number assigned on the x.25 data module screen. Interface Chan The interface channel number must be in the range 1 – 64 for an X.25 link. Destination Node Used for TCP/IP connections only. Destination Port Used for TCP/IP connections only. 1 of 4
Configuration 3:R8si R8r Gateway R8si 3 C-LAN Administration Administration for Network Connectivity CID: 77730 555-233-504 — Issue 1 — April 2000 110 Session - Local The Local and Remote Session numbers can be any value between 1 and 256 (si model) or 384 (r model), but they must be consistent between endpoints. For each connection, the Local Session number on this switch must equal the Remote Session number on the remote switch and vice versa. It is allowed, and sometimes convenient, to use the same number for the Local and Remote Session numbers. It is allowed, but not recommended, to use the same Session numbers for two or more connections. Session - Remote Mach ID Destination switch ID identified on the dial plan of the destination switch. Processor Channel 23: (The X.25 side of the gateway) Enable Set to y. Appl. Use gtwy-tcp for conversion between X.25 and TCP/IP. Gateway To Indicates a software connection between processor channels 23 and 32. Mode Used for TCP/IP connections only. Interface Link This must match the link number assigned on the x.25 data module screen. Interface ChanThe interface channel number must be in the range 1 – 64 for an X.25 link. Destination Node Used for TCP/IP connections only. Destination Port Used for TCP/IP connections only. Session - Local For each connection, the Local Session number on this switch must equal the Remote Session number on the remote switch and vice versa. Session - Remote Mach ID Leave blank for gtwy-tcp. Processor Channel 31: (ethernet connection to Switch 3) Enable Set to y. Appl. Set to dcs for DCS signaling. Mode Node-1 is the “server” for this session. Set node-3 to “client” (c). Interface Link This must match the link number assigned on the node-1 data module screen. Field Conditions/Comments 2 of 4