Here you can view all the pages of manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Administration For Network Connectivity Instructions Manual. The Lucent Technologies manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 131

Configuration 3:R8si R8r Gateway 
 R8si 
111
Administration for Network Connectivity
555-233-504— Issue 1 — April 2000 CID: 77730
3  C-LAN Administration
Interface Chan For TCP/IP, interface channel numbers are in the range 5000 
– 64500.
The recommended values are: 5001 for CMS, 5002 for Intuity 
AUDIX, and 5003 for DCS connections that are not 
gateways. These three values should be reused for multiple 
instances of these applications; for example, if there are two 
Intuity AUDIX’s, use 5002 for both;...

Page 132

Configuration 3:R8si R8r Gateway 
 R8si 3  C-LAN Administration
Administration for Network Connectivity
CID: 77730 555-233-504 — Issue 1 — April 2000
112
> Submit the screen
End
Destination Port A value of 0 allows any available interface channel on the 
destination node to be used for this connection. The Interface 
Channel number on the Switch-3 Processor Channel screen 
must also be set to 0.
Session - Local  For each connection, the Local Session number on this 
switch must equal the Remote Session...

Page 133

Configuration 3:R8si R8r Gateway 
 R8si 
113
Administration for Network Connectivity
555-233-504— Issue 1 — April 2000 CID: 77730
3  C-LAN Administration
Switch 2 Task — Assign Link via procr-intf Data Module to Switch 1
This task administers a processor-interface data module for the x.25 connection to 
node 1. The data module associates a link number with a physical channel number 
and extension number for the PI port used for this connection.
Begin
Steps
> Open Data Module form — enter  a da n
> Enter...

Page 134

Configuration 3:R8si R8r Gateway 
 R8si 3  C-LAN Administration
Administration for Network Connectivity
CID: 77730 555-233-504 — Issue 1 — April 2000
114
Enable Link?: Set to y after the processor channels have been 
assigned.
Maintenance Extension: Specified on dial plan.
Destination Number: TAC (812) + extension (2102) of the data module on 
the far end that will establish the connection.
Establish Connection?n means that the switch at the remote end of this 
connection (Switch 1 in this case) will be...

Page 135

Configuration 3:R8si R8r Gateway 
 R8si 
115
Administration for Network Connectivity
555-233-504— Issue 1 — April 2000 CID: 77730
3  C-LAN Administration
Switch 2 Task — Assign Processor Channels
This task associates data links (hardware) with processor channels (software) on 
Switch 2.
Begin
Steps
> Open Processor Channel Assignment form — enter  ch com p
Note:The Processor Channel number, the Interface Channel number, and the 
Local and Remote Session numbers do not need to be the same number 
but they...

Page 136

Configuration 3:R8si R8r Gateway 
 R8si 3  C-LAN Administration
Administration for Network Connectivity
CID: 77730 555-233-504 — Issue 1 — April 2000
116
> Submit the screen
End
Session - Local The Local and Remote Session numbers can be any value 
between 1 and 256 (si model) or 384 (r model), but they 
must be consistent between endpoints. For each 
connection, the Local Session number on this switch must 
equal the Remote Session number on the remote switch and 
vice versa.
It is allowed, and...

Page 137

Configuration 3:R8si R8r Gateway 
 R8si 
117
Administration for Network Connectivity
555-233-504— Issue 1 — April 2000 CID: 77730
3  C-LAN Administration
Switch 3 Task — Assign Node Names 
This task assigns node names and IP addresses to each node in the network. This 
screen is administered on Switch 3. A Node Names screen must be administered on 
each switch in the network.
The node names and IP addresses in any network should be assigned in a logical and 
consistent manner from the point of view of...

Page 138

Configuration 3:R8si R8r Gateway 
 R8si 3  C-LAN Administration
Administration for Network Connectivity
CID: 77730 555-233-504 — Issue 1 — April 2000
118
Switch 1 Task — Assign IP Interfaces
The IP interface for each C-LAN board on the switch must be defined on the IP 
Interfaces form. Each DEFINITY switch in an IP network has one IP Interfaces form.
Begin
Steps
> Open IP Interfaces form — enter  ch ip-i
> Enter values
change ip-interfaces  Page   1 of   2 
IP Interfaces
Inter-region IP connectivity...

Page 139

Configuration 3:R8si R8r Gateway 
 R8si 
119
Administration for Network Connectivity
555-233-504— Issue 1 — April 2000 CID: 77730
3  C-LAN Administration
Subnet Mask Enter the subnet mask associated with the IP address for 
this IP interface. (The IP address is associated with the 
node name on the Node Names screen). 
In this example, leave the default subnet mask, 
255.255.255.0, which indicates no subnetting for a Class 
C IP address.
See the discussion of subnetting, Subnetting  (page 16), in...

Page 140

Configuration 3:R8si R8r Gateway 
 R8si 3  C-LAN Administration
Administration for Network Connectivity
CID: 77730 555-233-504 — Issue 1 — April 2000
120
Switch 3 Task — Assign Link via ethernet Data Module to the LAN
This task administers an ethernet data module on Switch 3 for the ethernet connection 
to Switch 1. The data module associates a link number with a port address, extension 
number, and node name for the C-LAN port used for this connection.
Begin
Steps
> Open Data Module form — enter  a da n...