Home > Lucent Technologies > Communications System > Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Administration For Network Connectivity Instructions Manual

Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Administration For Network Connectivity Instructions Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Administration For Network Connectivity Instructions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 524
    							Configuration 3:R8si R8r Gateway 
     R8si 
    111
    Administration for Network Connectivity
    555-233-504— Issue 1 — April 2000 CID: 77730
    3  C-LAN Administration
    Interface Chan For TCP/IP, interface channel numbers are in the range 5000 
    – 64500.
    The recommended values are: 5001 for CMS, 5002 for Intuity 
    AUDIX, and 5003 for DCS connections that are not 
    gateways. These three values should be reused for multiple 
    instances of these applications; for example, if there are two 
    Intuity AUDIX’s, use 5002 for both; or if there are four 
    DEFINITY ECS’s, use 5003 for all four. The combination of 
    Link, Interface Channel, and Mach ID must be unique.
    Destination Node Name of the far-end node for this channel. This must be a 
    name entered on the Node Names screen.
    Destination Port A value of 0 allows any available interface channel on the 
    destination node to be used for this connection. The Interface 
    Channel number on the Switch-3 Processor Channel screen 
    must also be set to 0.
    Session - Local For each connection, the Local Session number on this switch 
    must equal the Remote Session number on the remote switch 
    and vice versa. Session - Remote
    Mach ID Destination switch ID identified on the dial plan of the 
    destination switch.
    Processor Channel 32: (The Ethernet side of the gateway)
    Enable Set to y.
    Appl. Use gtwy-tcp for conversion between X.25 and TCP/IP.
    Gateway To Indicates a software connection between processor channels 
    32 and 23.
    Mode Node-1 is the “server” for this session. Set node-3 to “client” 
    (c).
    Interface Link This must match the link number assigned on the data module 
    screen.
    Interface Chan For TCP/IP, interface channel numbers are in the range 5000 
    – 64500.
    The recommended values are: 5001 for CMS, 5002 for Intuity 
    AUDIX, and 5003 for DCS connections that are not 
    gateways. The combination of Link, Interface Channel, and 
    Mach ID must be unique.
    The recommended values for gateway switches is 
    6001–6099. The interface channel number must be unique for 
    each gateway.
    Destination Node Name of the far-end node for this channel. This must be a 
    name entered on the Node Names screen. Field Conditions/Comments
    3 of 4 
    						
    							Configuration 3:R8si R8r Gateway 
     R8si 3  C-LAN Administration
    Administration for Network Connectivity
    CID: 77730 555-233-504 — Issue 1 — April 2000
    112
    > Submit the screen
    End
    Destination Port A value of 0 allows any available interface channel on the 
    destination node to be used for this connection. The Interface 
    Channel number on the Switch-3 Processor Channel screen 
    must also be set to 0.
    Session - Local  For each connection, the Local Session number on this 
    switch must equal the Remote Session number on the remote 
    switch and vice versa. Session - Remote
    Mach ID Leave blank for gtwy-tcp. Field Conditions/Comments
    4 of 4 
    						
    							Configuration 3:R8si R8r Gateway 
     R8si 
    113
    Administration for Network Connectivity
    555-233-504— Issue 1 — April 2000 CID: 77730
    3  C-LAN Administration
    Switch 2 Task — Assign Link via procr-intf Data Module to Switch 1
    This task administers a processor-interface data module for the x.25 connection to 
    node 1. The data module associates a link number with a physical channel number 
    and extension number for the PI port used for this connection.
    Begin
    Steps
    > Open Data Module form — enter  a da n
    > Enter values.
    add data-module next                                                                    
    Page 1 of 1
                                     DATA MODULE
      Data Extension: 4121 Name: _x.25 on link 2 to node-1
    __
               Type: procr-intf
     COS: 1       Maintenance Extension: 4191Physical Channel: 02_ COR: 1       Destination Number: 8122102            ITC: Restricted TN: 1      Establish Connection? n
               Link: 2_ DTE/DCE: dce  Connected Data Module: _______
                           Enable Link: n
    ABBREVIATED DIALING
      List1: _______________
    SPECIAL DIALING OPTION: ________________
        
    ASSIGNED MEMBER (Station with a data extension button for this data module)
             Ext               Name
        1.
    Field Conditions/Comments
    Type: This indicates the data-module type for this 
    connection.
    Physical Channel: This must be the same as the link number.
    ITC: Enter restricted. (unrestricted is used only for 
    wideband transmission.)
    Link: The link number must be in the range 1 –25 (for 
    R8si), not previously assigned on this switch.
    Name: Information-only; appears in list generated by the “list 
    data module” command.
    COS:
    The values for these fields will be specified by the 
    system administrator. COR:
    TN:
    DTE/DCE: The DTE/DCE assignments must be opposites on the 
    two ends of the connection. Use dte for node 1.
    1 of 2 
    						
    							Configuration 3:R8si R8r Gateway 
     R8si 3  C-LAN Administration
    Administration for Network Connectivity
    CID: 77730 555-233-504 — Issue 1 — April 2000
    114
    Enable Link?: Set to y after the processor channels have been 
    assigned.
    Maintenance Extension: Specified on dial plan.
    Destination Number: TAC (812) + extension (2102) of the data module on 
    the far end that will establish the connection.
    Establish Connection?n means that the switch at the remote end of this 
    connection (Switch 1 in this case) will be responsible 
    for the call setup. Enter y when administering the data 
    module for Switch 1.
    Connected Data 
    Module:This is an information-only field.
    Keep the default values for the rest of the fields. Field Conditions/Comments
    2 of 2 
    						
    							Configuration 3:R8si R8r Gateway 
     R8si 
    115
    Administration for Network Connectivity
    555-233-504— Issue 1 — April 2000 CID: 77730
    3  C-LAN Administration
    Switch 2 Task — Assign Processor Channels
    This task associates data links (hardware) with processor channels (software) on 
    Switch 2.
    Begin
    Steps
    > Open Processor Channel Assignment form — enter  ch com p
    Note:The Processor Channel number, the Interface Channel number, and the 
    Local and Remote Session numbers do not need to be the same number 
    but they should be made the same whenever possible to simplify network 
    “bookkeeping” and diagnostics.
    > Enter values
    change communications-interface processor-channels
                                                                    Page 1 of X
    PROCESSOR CHANNEL ASSIGNMENT
    Proc                Gtwy        Interface    Destination      Session    Mach
    Chan Enable  Appl.  To  Mode  Link/Chan   Node       Port  Local/Remote  ID
      1:  n
      _______  _    __  _____  _________  0____  ___   ___    __
      2:  n  _______  _    __  _____  _________  0____  ___   ___    __
       :
    21:    y
     dcs____   _   2_ 21___ _________ 0____  21_   21_    1_
    23:    y
     dcs____  _  2_ 23___ _________ 0__23_   23_    3_
       :    
    256: n
      _______ _    __  _____  _________  0____  ___   ___    __
    Field Conditions/Comments
    Processor Channel 21: (X.25 connection to Switch 1)
    Enable Set to y.
    Appl. Set to dcs for DCS signaling.
    Mode Used for TCP/IP connections only.
    Interface Link This must match the link number assigned on the procr-intf 
    data module screen.
    Interface Chan The interface channel number must be in the range 1 – 64 
    for an X.25 link.
    Destination Node Used for TCP/IP connections only.
    Destination Port Used for TCP/IP connections only.
    1 of 2 
    						
    							Configuration 3:R8si R8r Gateway 
     R8si 3  C-LAN Administration
    Administration for Network Connectivity
    CID: 77730 555-233-504 — Issue 1 — April 2000
    116
    > Submit the screen
    End
    Session - Local The Local and Remote Session numbers can be any value 
    between 1 and 256 (si model) or 384 (r model), but they 
    must be consistent between endpoints. For each 
    connection, the Local Session number on this switch must 
    equal the Remote Session number on the remote switch and 
    vice versa.
    It is allowed, and sometimes convenient, to use the same 
    number for the Local and Remote Session numbers. It is 
    allowed, but not recommended, to use the same Session 
    numbers for two or more connections. Session - Remote
    Mach ID Destination switch ID identified on the dial plan of the 
    destination switch. This is usually called the “node 
    number.”
    Processor Channel 23: (connection to Switch 1 for gateway to Switch 3)
    Enable Set to y.
    Appl. Set to dcs for DCS signaling.
    Mode Used for TCP/IP connections only.
    Interface Link This must match the link number assigned on the procr-intf 
    data module screen.
    Interface Chan The interface channel number must be in the range 1 – 64 
    for an X.25 link.
    Destination Node Used for TCP/IP connections only.
    Destination Port Used for TCP/IP connections only.
    Session - Local For each connection, the Local Session number on this 
    switch must equal the Remote Session number on the 
    remote switch and vice versa. Session - Remote
    Mach ID Destination switch ID identified on the dial plan of the 
    destination switch. Field Conditions/Comments
    2 of 2 
    						
    							Configuration 3:R8si R8r Gateway 
     R8si 
    117
    Administration for Network Connectivity
    555-233-504— Issue 1 — April 2000 CID: 77730
    3  C-LAN Administration
    Switch 3 Task — Assign Node Names 
    This task assigns node names and IP addresses to each node in the network. This 
    screen is administered on Switch 3. A Node Names screen must be administered on 
    each switch in the network.
    The node names and IP addresses in any network should be assigned in a logical and 
    consistent manner from the point of view of the whole network. These names and 
    addresses should be assigned in the planning stages of the network and should be 
    available from the customer system administrator or from a Lucent representative.
    Note:Enter node names for Intuity AUDIX and MSA adjuncts on page 1. Enter 
    node names for switches, routers, and CMS starting on page 2.
    Begin
    Steps
    > Open Node Names form — enter  ch node-n
    > Go to page 2.
    > Enter values.
    > Submit the screen
    End
    change node-names
                                                                        Page 2 of 6
                                     NODE NAMES
       Name              IP Address          Name  IP Address
    default
    __________ 0__.0__.0__.0__ _______________ ___.___.___.___
    node-1 _ _  192.168.10_.1__  _______________    ___.___.___.___
    node-3____        192.168.10_.3__  _______________    ___.___.___.___
    ________________   ___.___.___.___  _______________    ___.___.___.___
    Field Conditions/Comments
    Name Enter unique node names for the following 2 nodes:
    •C-LAN Ethernet port on Switch 3
    •C-LAN Ethernet port on Switch 1.
    IP Address The unique IP addresses of the nodes named in the previous 
    field. 
    						
    							Configuration 3:R8si R8r Gateway 
     R8si 3  C-LAN Administration
    Administration for Network Connectivity
    CID: 77730 555-233-504 — Issue 1 — April 2000
    118
    Switch 1 Task — Assign IP Interfaces
    The IP interface for each C-LAN board on the switch must be defined on the IP 
    Interfaces form. Each DEFINITY switch in an IP network has one IP Interfaces form.
    Begin
    Steps
    > Open IP Interfaces form — enter  ch ip-i
    > Enter values
    change ip-interfaces  Page   1 of   2 
    IP Interfaces
    Inter-region IP connectivity allowed?  n
    Enable Net
    Eth Pt Type   Slot  Code Sfx Node Name   Subnet Mask  Gateway Addr Rgn
    y
       C-LAN 01a10 TN799 B node-1 255.255.255.0  .._. 1
    n 255.255.255.0  n 255.255.255.0  n 255.255.255.0  
    Field Conditions/Comments
    Inter-region IP 
    connectivity 
    allowed?Enter y to allow IP endpoints (phones and trunks) to use 
    MedPro resources administered in regions that are 
    different from the endpoints’ regions.
    Enable Eth Pt The Ethernet port must be enabled (y) before it can be 
    used. The port must be disabled (n) before changes can be 
    made to its attributes on this screen.
    Type Enter c-lan or medpro.
    Slot Enter the slot location for the circuit pack.
    Code Display only. This field is automatically populated with 
    TN799 for C-LAN or TN802 for MedPro.
    Sfx Display only. This field is automatically populated with B 
    for the TN802 and TN799.
    Node name Enter the unique node name for the IP interface. The node 
    name here must already be administered on the Node 
    Names screen
    1 of 2 
    						
    							Configuration 3:R8si R8r Gateway 
     R8si 
    119
    Administration for Network Connectivity
    555-233-504— Issue 1 — April 2000 CID: 77730
    3  C-LAN Administration
    Subnet Mask Enter the subnet mask associated with the IP address for 
    this IP interface. (The IP address is associated with the 
    node name on the Node Names screen). 
    In this example, leave the default subnet mask, 
    255.255.255.0, which indicates no subnetting for a Class 
    C IP address.
    See the discussion of subnetting, Subnetting  (page 16), in 
    Chapter 1 and Configuration 1: R8r  R8si  
    (page 60) in this chapter for details about subnet masks.
    Gateway Addr Leave blank for this configuration. The only connection 
    to this IP interface is node-1 on Switch 1. Node-1 is on 
    the same subnetwork as this IP interface, so no gateway is 
    needed.
    In general, for connectivity to other (sub)networks, enter 
    the address of a network node that will serve as the 
    default gateway to the other (sub)networks.
    Net Rgn Enter the region number for this IP interface. Field Conditions/Comments
    2 of 2 
    						
    							Configuration 3:R8si R8r Gateway 
     R8si 3  C-LAN Administration
    Administration for Network Connectivity
    CID: 77730 555-233-504 — Issue 1 — April 2000
    120
    Switch 3 Task — Assign Link via ethernet Data Module to the LAN
    This task administers an ethernet data module on Switch 3 for the ethernet connection 
    to Switch 1. The data module associates a link number with a port address, extension 
    number, and node name for the C-LAN port used for this connection.
    Begin
    Steps
    > Open Data Module form — enter  a da n 
    > Enter values.
    > Submit the screen
    End
    add data module next              Page 1 of x
                       DATA MODULE
    Data Extension: 4531          Name: ethernet on link 3 
     BCC: 2
                  Type: ethernet
                  Port: 01a1017              Link: 3_
    Network uses 1’s for broadcast addresses? y
    Field Conditions/Comments
    Type: This indicates the data-module type for this connection.
    Port: In this example, the C-LAN circuit pack is in slot 01a10; the 
    ethernet connection is through port 17.
    Link:The link number must be in the range 1 – 25 (for R8si), not 
    previously assigned on this switch.
    Name: Information-only; appears in the “list data module” command list.
    Network 
    uses 1’s for 
    broadcast 
    addresses?Leave the default (y) if the private network contains only 
    DEFINITY switches and adjuncts. Set to n only if the network 
    includes non-DEFINITY switches that use the 0’s method of 
    forming broadcast addresses. See Appendix A, “Data Module - 
    type ethernet” for more information about this field. 
    						
    All Lucent Technologies manuals Comments (0)

    Related Manuals for Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Administration For Network Connectivity Instructions Manual