Home > Lucent Technologies > Communications System > Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Administration For Network Connectivity Instructions Manual

Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Administration For Network Connectivity Instructions Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Administration For Network Connectivity Instructions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 524
    							Configuration 5B:R8csi  R8r (2 C-LANs) 
     R8si 
    171
    Administration for Network Connectivity
    555-233-504— Issue 1 — April 2000 CID: 77730
    3  C-LAN Administration
    Configuration 5B:R8csi  R8r (2 C-LANs)  R8si 
    In this configuration, a DEFINITY ECS R8r acts as a gateway between two other 
    nodes — one connected via ppp to an R8csi and the other via ethernet to another R8si. 
    This configuration is the same as configuration 5A except that Switch 1 has two 
    C-LAN circuit packs instead of one. One C-LAN handles the ppp connection and the 
    other handles the ethernet connection.  
    Task Summary
    The following tasks need to be completed for Switch 1, Switch 2, and Switch 3:
    1  Review checklist
    2  Switch 1 administration
     a  Assign node names
     b  Assign link to (via a data module) to node-2
     c  Assign link to (via a data module) to the LAN
     d  Assign link (via a data module) from C-LAN(a) to C-LAN(b)
     e  Assign link (via a data module) from C-LAN(b) to C-LAN(a)
     f  Assign processor channels
     g  Assign IP Route: C-LAN(a) to node-3
     h  Assign IP Route: C-LAN(b) to node-2
    3  Switch 2 administration
     a  Enable bus bridge connectivity
     b  Assign node names
     c  Assign link (via a data module) to node-1a-ppp
     d  Assign processor channels
     e  Assign IP Route to node-3
    DEFINITY
    ECS R8r
    ppp
    Switch 1
    DEFINITY ECS
    Switch 3
    DEFINITY ECS
    Switch 2
    R8si
    Hub
    Ethernet
    R8csi
    C-LAN(b)C-LAN
    ppp
    node-1b-ethnode-3 node-1a-pppnode-2
    node-1a
    node-1b
    DS1
    C-LAN
    DS1
    C-LAN(a) 
    						
    							Configuration 5B:R8csi  R8r (2 C-LANs) 
     R8si 3  C-LAN Administration
    Administration for Network Connectivity
    CID: 77730 555-233-504 — Issue 1 — April 2000
    172
    4  Switch 3 administration
     a  Assign node names
     b  Assign link (via a data module) to the LAN
     c  Assign processor channels
    5  Enable links and processor channels
    Prerequisite Administration
    There are some system administration tasks that need to be completed before you can 
    proceed with the connectivity administration described in this section.
    Review the checklist of prerequisite administration tasks in the Checklist for 
    Prerequisite Administration  (page 54), before proceeding with the connectivity 
    administration in this section. 
    						
    							Configuration 5B:R8csi  R8r (2 C-LANs) 
     R8si 
    173
    Administration for Network Connectivity
    555-233-504— Issue 1 — April 2000 CID: 77730
    3  C-LAN Administration
    SWITCH 2 SWITCH 1 SWITCH 3
    Configuration 5B
    DEFINITY ECS R7csi DEFINITY ECS R7r DEFINITY ECS R7si
    Processor
    channelsProcessor
    channelsProcessor
    channelsInterface
    channelsInterface
    channelsInterface
    channelsInterface
    channels
    1
    2
    21
    23
    1281
    500
    x(any)
    6004
    645001
    2
    31
    32
    256 1
    5000
    645001
    5000
    5003
    645001
    5000
    5003
    64500 1
    12
    13
    384
    Link 1 Link 1
    Link 12 Link 21Link 2Link 1
    x
    x1
    2(any)
    (any)
    Bus
    bridge
    hardware connections
    Processor
    UN331B
    C-LAN(a)
    TN799C-LAN(b)
    TN799 PktInt
    TN1655DS1
    TN767/
    TN464 DS1
    TN767/
    TN464
    Processor bus
    TDM
    bus
    Packet bus
    ppp10BaseT
    ethernet
    Processor
    TN790B
    Processor bus
    TDM bus
    TDM bus
    Packet bus Packet bus
    NetPkt
    TN794 DS1
    TN767/
    TN464 DS1
    TN767/
    TN464Processor
    TN798BVoice
    data
    Voice
    data
    ppp
    dataNetwork
    control
    UN332B
    56
    4321
    cydfec5b EWS 051799
    node-2
    Ext 3020
    loc 1a0413
    192.168.10.12node-1a-ppp
    Ext 2010
    loc 1c0709
    192.168.10.11node-1a
    Ext 2013
    loc 1c0713
    192.168.10.13node-1b
    Ext 2378
    loc 1c0815
    192.168.10.130node-1b-eth
    Ext 2377
    loc 1c0817
    192.168.10.128node-3
    Ext 3901
    loc 1a0517
    192.168.10.129
    132465
    C-LAN
    TN799 C-LAN
    TN799
    software-defined connections 
    						
    							Configuration 5B:R8csi  R8r (2 C-LANs) 
     R8si 3  C-LAN Administration
    Administration for Network Connectivity
    CID: 77730 555-233-504 — Issue 1 — April 2000
    174
    Switch 1 Task — Assign Node Names
    This task assigns node names and IP addresses to each node in the network. This 
    screen is administered on Switch 1. A Node Names screen must be administered on 
    each switch in the network.
    Note:Enter node names for Intuity AUDIX and MSA adjuncts on page 1. Enter 
    node names for switches, routers, and CMS starting on page 2.
    Begin
    Steps
    > Open Node Names form — enter  ch node-n
    > Go to page 2
    > Enter values.
    > Submit the screen1
    End
    change node-names  Page 2 of 6
                                 NODE NAMES
    Name              IP Address  Name                IP Address
    default
    _________ 0__.0__.0__.0__ _______________ ___.___.___.___
    node-1a-ppp 192.168.10_.11_   _______________    ___.___.___.___
    node-1a
    ______  192.168.10_.13________________ ___.___.___.___
    node-1b  ______  192.168.10_.130_______________ ___.___.___.___
    node-1b-eth __  192.168.10_.128   _______________    ___.___.___.___
    node-2____ 
    192.168.10_.12_   _______________    ___.___.___.___
    node-3____  192.168.10_.129  _______________    ___.___.___.___
    Field Conditions/Comments
    Name Enter unique node names for the following 6 nodes:
    •C-LAN(a) PPP port on Switch 1 for the connection to Switch 2
    •C-LAN(a) PPP port on Switch 1 for the connection to C-LAN(b)
    •C-LAN(b) PPP port on Switch 1 for the connection to C-LAN(a)
    •C-LAN(b) Ethernet port on Switch 1
    •C-LAN PPP port on Switch 2.
    •C-LAN Ethernet port on Switch 3
    IP Address The unique IP addresses of the nodes named in the previous field. 
    						
    							Configuration 5B:R8csi  R8r (2 C-LANs) 
     R8si 
    175
    Administration for Network Connectivity
    555-233-504— Issue 1 — April 2000 CID: 77730
    3  C-LAN Administration
    Switch 1 Task — Assign Link via ppp Data Module to Switch 2
    This task administers a ppp data module on Switch 1 for the ppp connection to Switch 
    2. The data module associates a link number with a port address, extension number, 
    and node name for the C-LAN port used for this connection.
    Begin
    Steps
    > 
    Open Data Module form — enter ad da 2010
    > Enter values
    add data-module 2010 
                                                                     Page 1 of x
                              DATA MODULE
        Data Extension: 2010            Name: _ppp on link 1 to node 2___
      BCC: 2
                  Type: ppp
         COS: 1              Port: 01c0709 COR: 1              Link: 1_            TN: 1
           Enable Link? n
             Node Name: node-1a-ppp _
    Subnet Mask: 255.255.255.0 
    Establish Connection: y
    DESTINATION
                Digits: 8993020
    _________
          Node Name: node-2__________
                  CHAP? n
    Field Conditions/Comments
    Type: This indicates the data-module type for this link.
    Port: In this example, the C-LAN(a) circuit pack is in slot 01c07; the 
    ppp connection is through port 09.
    Link: The link number must be in the range 1 – 33 (for R8r), not 
    previously assigned on this switch.
    Enable Link? If you need to add an IP route that uses this node as a gateway, 
    this field must be set to 
    y before adding the IP route. Otherwise 
    leave this field set to 
    n until the link administration is complete; 
    that is, until after all data modules and the processor channels are 
    assigned, then set to 
    y.
    Name: Information-only; appears in list generated by the “list data 
    module” command.
    BCC: Bearer Capability Class. This is a display-only field.
    1 of 2 
    						
    							Configuration 5B:R8csi  R8r (2 C-LANs) 
     R8si 3  C-LAN Administration
    Administration for Network Connectivity
    CID: 77730 555-233-504 — Issue 1 — April 2000
    176
    > Submit the screen
    End
    COS
    The values for these fields will be specified by the system 
    administrator. COR:
    TN:
    Node Name: The node name for the interface defined by this data module. This 
    must be a name entered on the Node Names screen.
    Establish 
    Connection?y means that this switch will be responsible for the call setup. 
    Enter n when administering the data module for Switch 2.
    Destination 
    Digits:Trunk access code (899) plus extension of data module on node-2 
    (3020).
    Destination 
    Node Name:Name of the node at the far end of this connection. Must be a 
    name entered on the Node Names screen
    CHAP? This field enables/disables the Challenge Handshake 
    Authentication Protocol security mechanism on this link. If you 
    enter y, the system will prompt for a CHAP secret (password). Field Conditions/Comments
    2 of 2 
    						
    							Configuration 5B:R8csi  R8r (2 C-LANs) 
     R8si 
    177
    Administration for Network Connectivity
    555-233-504— Issue 1 — April 2000 CID: 77730
    3  C-LAN Administration
    Switch 1 Task — Assign IP Interfaces
    The IP interface for each C-LAN board on the switch must be defined on the IP 
    Interfaces form. Each DEFINITY switch in an IP network has one IP Interfaces form.
    Begin
    Steps
    > Open IP Interfaces form — enter  ch ip-i
    > Enter values
    change ip-interfaces  Page   1 of   2 
    IP Interfaces
    Inter-region IP connectivity allowed?  n
    Enable Net
    Eth Pt Type   Slot  Code Sfx Node Name   Subnet Mask  Gateway Addr Rgn
    y
       C-LAN 01c08 TN799 B node-1b-eth 255.255.255.0  .._. 1
    n 255.255.255.0  n 255.255.255.0  n 255.255.255.0  
    Field Conditions/Comments
    Inter-region IP 
    connectivity 
    allowed?Enter y to allow IP endpoints (phones and trunks) to use 
    MedPro resources administered in regions that are 
    different from the endpoints’ regions.
    Enable Eth Pt The Ethernet port must be enabled (y) before it can be 
    used. The port must be disabled (n) before changes can be 
    made to its attributes on this screen.
    Type Enter c-lan or medpro.
    Slot Enter the slot location for the circuit pack.
    Code Display only. This field is automatically populated with 
    TN799 for C-LAN or TN802 for MedPro.
    Sfx Display only. This field is automatically populated with B 
    for the TN802 and TN799.
    Node name Enter the unique node name for the IP interface. The node 
    name here must already be administered on the Node 
    Names screen
    1 of 2 
    						
    							Configuration 5B:R8csi  R8r (2 C-LANs) 
     R8si 3  C-LAN Administration
    Administration for Network Connectivity
    CID: 77730 555-233-504 — Issue 1 — April 2000
    178
    Subnet Mask Enter the subnet mask associated with the IP address for 
    this IP interface. (The IP address is associated with the 
    node name on the Node Names screen). 
    In this example, leave the default subnet mask, 
    255.255.255.0, which indicates no subnetting for a Class 
    C IP address.
    See the discussion of subnetting , Subnetting  (page 16), 
    in Chapter 1 and Configuration 1: R8r  R8si  
    (page 60) in this chapter for details about subnet masks.
    Gateway Addr Leave blank for this configuration. The only connection 
    to this IP interface is node-3 on Switch 3, which is on the 
    same subnetwork as this IP interface, so no gateway is 
    needed.
    In general, for connectivity to other (sub)networks, enter 
    the address of a network node that will serve as the 
    default gateway to the other (sub)networks.
    Net Rgn Enter the region number for this IP interface. Field Conditions/Comments
    2 of 2 
    						
    							Configuration 5B:R8csi  R8r (2 C-LANs) 
     R8si 
    179
    Administration for Network Connectivity
    555-233-504— Issue 1 — April 2000 CID: 77730
    3  C-LAN Administration
    Switch 1 Task — Assign Link via ethernet Data Module to the LAN
    This task administers an ethernet data module on Switch 1 for the ethernet 
    connection. The data module associates a link number with a port address, extension 
    number, and node name for the C-LAN port used for this connection.
    Begin
    Steps
    > Open Data Module form — enter  a da n
    > Enter values
    > Submit the screen
    End
    add data next 
                                                                      Page 1 of X
                              DATA MODULE
        Data Extension: 2377            Name: ethernet on link 2
    BCC: 2
                  Type: ethernet
                  Port: 01c0817_
                  Link: 2 
    Network uses 1’s for broadcast addresses? y
    Field Conditions/Comments
    Type: This indicates the data-module type for this connection.
    Port: Ethernet connections must be assigned to port 17 on the 
    C-LAN(b) circuit pack.
    Link:The link number must be in the range 1 – 33 (for R8r), not 
    previously assigned on this switch.
    Name: Information-only; appears in list generated by the “list data 
    module” command.
    Network uses 
    1’s for 
    broadcast 
    addresses?Leave the default (y) if the private network contains only 
    DEFINITY switches and adjuncts. Set to n only if the network 
    includes non-DEFINITY switches that use the 0’s method of 
    forming broadcast addresses. See Appendix A, “Data Module - 
    type ethernet” for more information about this field. 
    						
    							Configuration 5B:R8csi  R8r (2 C-LANs) 
     R8si 3  C-LAN Administration
    Administration for Network Connectivity
    CID: 77730 555-233-504 — Issue 1 — April 2000
    180
    Switch 1 Task — Assign Link via ppp Data Module to C-LAN(a)
    This task administers a ppp data module on Switch 1 for the ppp connection from the 
    C-LAN(b) circuit pack to the C-LAN(a) circuit pack.
    Begin
    Steps
    > 
    Open Data Module form — enter ad da 2378
    > Enter values
    add data-module 2378 
                                                                     Page 1 of x
                               DATA MODULE
        Data Extension: 2378  Name: _ppp on link 21 to clan(a)_
     BCC: 2
                  Type: ppp
         COS: 1              Port: 01c0815 COR: 1              Link: 21TN: 1
           Enable Link? n
             Node Name: node-1b_____ 
    Subnet Mask: 255.255.255.0 
    Establish Connection: n
    DESTINATION
                Digits: 
    ______
          Node Name: node-1a______               CHAP? n
    Field Conditions/Comments
    Type: This indicates the data-module type for this link.
    Port: In this example, the C-LAN(b) circuit pack is in slot 01c08; the 
    ppp connection is through port 15.
    Link: The link number must be in the range 1 – 33 (for R8r), not 
    previously assigned on this switch
    Enable Link? If you need to add an IP route that uses this node as a gateway, 
    this field must be set to 
    y before adding the IP route. Otherwise 
    leave this field set to 
    n until the link administration is complete; 
    that is, until after all data modules and the processor channels are 
    assigned, then set to 
    y.
    Name: Information-only; appears in list generated by the “list data 
    module” command.
    BCC: Bearer Capability Class. This is a display-only field.
    1 of 2 
    						
    All Lucent Technologies manuals Comments (0)

    Related Manuals for Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Administration For Network Connectivity Instructions Manual