Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Administration For Network Connectivity Instructions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
Configuration 2: R7r (+CMS) R7csi 91 Administration for Network Connectivity 555-233-504— Issue 1 — April 2000 CID: 77730 3 C-LAN Administration Destination NodeName of the far-end node for this channel. This must be a name entered on the Node Names screen. Destination Port A value of 0 allows any available interface channel on the destination node to be used for this connection. The Interface Channel number on the Switch-2 Processor Channel screen must also be set to 0. Session - Local The Local and Remote Session numbers can be any value between 1 and 256 (si model) or 384 (r model), but they must be consistent between endpoints. For each connection, the Local Session number on this switch must equal the Remote Session number on the remote switch and vice versa. It is allowed, and sometimes convenient, to use the same number for the Local and Remote Session numbers. It is allowed, but not recommended, to use the same Session numbers for two or more connections. Session - Remote Mach ID This field is not used for CMS. Processor Channel 21: (ethernet connection to Switch 1) Enable Set to y. Appl.dcs indicates that this connection will carry DCS data. ModeNode-5 will be the “client” on this session. Set node-1 (on Switch 1) to “server” (s). Interface Link This must match the link number assigned on the node-5 data module screen. Interface Chan A value of 0 allows any available interface channel to be used for this connection. The Destination Port number on the Switch-1 Processor Channel screen must also be set to 0. Destination NodeName of the far-end node for this channel. This must be a name entered on the Node Names screen. Destination Port This number must match the Interface Channel number assigned on the Switch-1 Processor Channel screen. Field Conditions/Comments 2 of 3
Configuration 2: R7r (+CMS) R7csi 3 C-LAN Administration Administration for Network Connectivity CID: 77730 555-233-504 — Issue 1 — April 2000 92 > Submit the screen End Intuity System Administration Procedure OverviewThe following is a checklist of procedures that must be completed to administer a DEFINITY ECS with a TCP/IP connection to a Lucent Intuity system. The DEFINITY administration procedures are described in DEFINITY ECS Administrator’s Guide, 555-233-502 and in previous sections of this chapter. The Intuity system administration procedures are describe following the checklist. For a complete description of the administration procedures for connecting an Intuity system to a DEFINTIY ECS, see Intuity Messaging Solutions — Using a LAN to Integrate with DEFINTIY ECS, 585-313-602 for Intuity R4.4 or 585-313-604 for Intuity R5. DEFINITY ECS administration The following procedures must be done on the host switch: •Administer the local node number in the dial plan. •Administer the Intuity system voice ports as stations, including Class of Restriction (COR) and Class of Service (COS). •If the switch is a csi model, assign the bus bridge. •Assign node names for the Intuity system and the switch. •Administer a hunt group, and add the Intuity system voice ports to that hunt group. •Add an ethernet data module. •Administer a processor channel for the link from the switch to the Intuity system. •Enable the link on the ethernet data module. •Set up a coverage path for access to the voice port hunt group. Session - Local The Local and Remote Session numbers can be any value between 1 and 256 (si model) or 384 (r model), but they must be consistent between endpoints. For each connection, the Local Session number on this switch must equal the Remote Session number on the remote switch and vice versa. It is allowed, and sometimes convenient, to use the same number for the Local and Remote Session numbers. It is allowed, but not recommended, to use the same Session numbers for two or more connections. Session - Remote Mach ID Destination switch ID. This is the Local Node Number on the dial plan of the destination switch. Field Conditions/Comments 3 of 3
Configuration 2: R7r (+CMS) R7csi 93 Administration for Network Connectivity 555-233-504— Issue 1 — April 2000 CID: 77730 3 C-LAN Administration •Apply the coverage path to stations, and if the switch is an r model, specify the node name of the Intuity system for each station that has a voice mailbox on the Intuity system. Intuity system administration The following procedures must be done on the Intuity system: •Administer the UNIX name and IP address for the Intuity system. •Administer the switch interface link to the host switch. This includes the Extension Length, Host Switch Number, AUDIX Number, Switch Number, Switch IP Address, and TCP Port. •Administer extension numbers, channels, and services. •Administer subscribers. Administer the TCP/IP Network AddressingDo the following procedures to administer the Intuity system. If not already done, you must set up the basic networking addressing for the Intuity system. Do the following: 1 Beginning at the Lucent INTUITY Main menu, select: The system responds with the Network Addressing window. 2 Use Worksheet A to enter the correct values in this window. 3 Press F3 (Save). 4 Continue with the next procedure, “Administer Switch Interface.” > Network Ad d ressing > TCP/IP Ad ministration +-------------------------------------------------------+ + Network Addressing + +-------------------------------------------------------+ | TCP/IP Interface: eeE_0| | Host Name: denaudix| |IP Address: 192.168.1.125 | Subnet Mask: 192.168.1.224| |Default Gateway IP Address: 192.168.1.97| +-------------------------------------------------------+
Configuration 2: R7r (+CMS) R7csi 3 C-LAN Administration Administration for Network Connectivity CID: 77730 555-233-504 — Issue 1 — April 2000 94 Administer the Switch InterfaceYou must now administer the switch interface. Do the following. 1 Starting at the Lucent INTUITY Main menu, select: The system responds with the Switch Interface Administration window. 2 Use Worksheet B to enter the correct values in this window. 3 Press F3 (Save). 4 Continue with the next procedure, “Administer Extension Numbers, Channels, and Services.” Administer Extension Numbers, Channels, and ServicesTo associate the switch voice ports, you must do the following on the Intuity system: •Map channels to switch extensions •Map services to channels •Assign services to called numbers. For more information on this, see “Administering Channels” in the Lucent I NTUITY Messaging Solutions Release 5 documentation. Continue with the next procedure, “Administer Subscribers.” > Switch Link Administration > Call Data Interface Administration > Switch Interface Administration +-------------------------------------------------------------------------+ + Switch Interface Administration + +-------------------------------------------------------------------------+ | Switch Link Type: LAN Country: UNITED STATES | | Extension Length: 4 Switch: DEFINITY OVERLAN | | Host Switch Number: 1 | | AUDIX Number: 1 | || |Switch IP Address/ TCP Switch IP Address/ TCP | |Number Host Name Port Number Host Name Port | | 1 192.168.1.124 5002 | | | | | | | | |
Configuration 2: R7r (+CMS) R7csi 95 Administration for Network Connectivity 555-233-504— Issue 1 — April 2000 CID: 77730 3 C-LAN Administration Administer Subscribers Subscribers must be administered on the Intuity system. For more information on this, see the Lucent I NTUITY Messaging Solutions Release 5 documentation. The following screens show examples of subscriber screens on the Intuity system. add subscriber 3066 Page 1 of 2 SUBSCRIBER Name: Jean Collins Locked? n Extension: 150 Password: COS: class00 Miscellaneous: Switch Number: 1 Covering Extension: 161 Community ID: 1 Broadcast Mailbox? n Secondary Ext: Account Code: add subscriber 3066 Page 2 of 2 SUBSCRIBER CLASS OF SERVICE PARAMETERS Addressing Format: extension Login Announcement Set: System System Multilingual is ON Call Answer Primary Annc. Set: System Call Answer Language Choice? n Call Answer Secondary Annc. Set: System PERMISSIONS Type: call-answer Announcement Control? y Outcalling? n Priority Messages? n Broadcast: none IMAPI Access? y IMAPI Message Transfer? n Fax Creation? n Trusted Server Access? y INCOMING MAILBOX Order: fifo Category Order: nuo Retention Times (days), New: 10 Old: 10 Unopened: 10 OUTGOING MAILBOX Order: fifo Category Order: unfda Retention Times(days), File Cab: 10 Delivered/Nondeliverable: 5 Voice Mail Message (seconds), Maximum Length: 300 Minimum Needed: 32 Call Answer Message (seconds), Maximum Length: 120 Minimum Needed: 8 End of Message Warning Time (seconds): Maximum Mailing Lists: 25 Total Entries in all Lists: 250 Mailbox Size (seconds), Maximum: 3600 Minimum Guarantee: 0
Configuration 2: R7r (+CMS) R7csi 3 C-LAN Administration Administration for Network Connectivity CID: 77730 555-233-504 — Issue 1 — April 2000 96 Worksheet A: Names and IP Addresses for Lucent Intuity System Complete the information on this worksheet to collect information required to administer the Lucent I NTUITY system for integration with the switch. Field Recommended Your Entry Intuity System TCP/IP Administration Screen (TCP/IP Administration, Network Addressing or Networking Administration, TCP/IP Administration) TCP/IP Interface eeE_0 Host Name (called UNIX Machine Name on R4.4) This information may already be administered. If not, enter the UNIX name for this machine. The name is case-sensitive. denaudix IP Address IP address administered on the Lucent Intuity system 192.168.1.125 Subnet Mask 192.168.1.224 Default Gateway IP Address 192.168.1.97
Configuration 2: R7r (+CMS) R7csi 97 Administration for Network Connectivity 555-233-504— Issue 1 — April 2000 CID: 77730 3 C-LAN Administration Worksheet B: LAN Data for the Lucent Intuity System Complete the information on this worksheet to administer the Lucent INTUITY system for integration with the switch. Field Recommended Your Entry Lucent INTUITY System Switch Interface Administration Window Extension Length Use the extension length from the switch dial plan 4 Host Switch Number Use 1 if the integration supports only one DEFINITY switch. If more than one DEFINITY system will be supported, use the number administered on the Local Node Number field in the host switch dial plan. 1 AUDIX Number The number assigned to the Lucent INTUITY system on the DEFINITY ECS. For r-model switches, a number from 1 to 8; for csi and si, 1. This must match the Machine-ID field of the Processor Channels screen. 1 Switch Number Enter the nod e numb er of the switc h b eing ad ministered . If there is only one switc h, the value must b e 1 . This must matc h the Local Node Number field in the switch dial p lan. 1 IP Address/Host Name Enter the IP address for the switch being administered. 192.168.1.124 TCP Port Enter a TCP port number for each Intuity AUDIX for each switch being administered. This must match the Interface Channel field of the Processor Channels screen. You should use 5002 for every switch linked over the LAN in a DCS network. Use the numbers6001-6999 for gateway TCP links to remote switches in a DCS network. 5002
Configuration 2: R7r (+CMS) R7csi 3 C-LAN Administration Administration for Network Connectivity CID: 77730 555-233-504 — Issue 1 — April 2000 98 Enable links and processor channels You must enable links and processor channels before the connections can be used. To enable a link, open its data module screen (ch da [ext]) and set the Enable Link? field to y. [note: to view a list of assigned data modules and their extensions, enter the “list data-module” command (l da)] To enable the processor channels, open the processor channel screen (ch com p) and set the Enable field to y for each assigned processor channel. Note:1. You must disable a link or processor channel before you can change its parameters. Note:2. The busy-out command overrules the data module Enable Link? field. Note:3. On the C-LAN boards, low-level connectivity can remain intact when higher-level applications such as DCS are not functioning. For example, an external ping to a C-LAN’s ethernet port could be successful even when the board is busied-out. When debugging connectivity problems, pinging only checks low-level connectivity.
Configuration 3:R8si R8r Gateway R8si 99 Administration for Network Connectivity 555-233-504— Issue 1 — April 2000 CID: 77730 3 C-LAN Administration Configuration 3:R8si R8r Gateway R8si In this configuration, a DEFINITY ECS R8r acts as a gateway between two other nodes — one connected via X.25 to an R8si and the other via ethernet to another R8si. Task Summary The following tasks need to be completed for Switch 1, Switch 2, and Switch 3: 1 Review checklist 2 Switch 1 administration a Assign node names b Assign pdm data module c Assign IP Interfaces d Assign link (via an x.25 data module) to Switch 2 e Assign link (via an ethernet data module) to the LAN f Assign processor channels 3 Switch 2 administration a Assign link (via a proc-intf data module) to node 1 b Assign processor channels 4 Switch 3 administration a Assign node names b Assign IP Interfaces c Assign link (via an ethernet data module) to the LAN d Assign processor channels 5 Enable links and processor channels DEFINITY ECS R8r BX.25Switch 1 DEFINITY ECS Switch 3 DEFINITY ECS Switch 2 R8si Hub Ethernet R8si C-LANC-LAN PI PGATE node-3 node-1 DS1 PDM
Configuration 3:R8si R8r Gateway R8si 3 C-LAN Administration Administration for Network Connectivity CID: 77730 555-233-504 — Issue 1 — April 2000 100 Prerequisite Administration There are some system administration tasks that need to be completed before you can proceed with the connectivity administration described in this section. Review the checklist of prerequisite administration tasks in Checklist for Prerequisite Administration (page 54), before proceeding with the connectivity administration in this section. SWITCH 2 SWITCH 1SWITCH 3 Configuration 3 DEFINITY ECS R7si DEFINITY ECS R7rDEFINITY ECS R7si Processor channelsProcessor channelsProcessor channelsInterface channelsInterface channelsInterface channelsInterface channels 1 2 2561 2 641 2 64 21 22 2321 22 2321 22 231 500 x(any) x(any) 645001 2 31 32 256 1 5000 5003 6002 64500 1 21 22 23 31 32 384 Link 2 Link 5 Link 3Link 3 Gateway-tcp hardware connections Processor UN331B PGATE TN577DS1 TN767/ TN464 DS1 TN767/ TN464 Digital line TN754 Processor bus Processor bus TDM bus RS232 Packet bus 10BaseT ethernet Processor TN790B Processor TN790B Processor bus TDM bus TDM bus Packet bus Packet bus NetPkt TN794 DS1 TN767/ TN464 DS1 TN767/ TN464 NetPkt TN794PI TN765 Voice data Voice data Network control UN332B 1 cydfec3a EWS 052099 Ext 4121 Ext 2102 loc 1c0102node-1 Ext 3391 loc 1b0117 192.168.10.1node-3 Ext 4351 loc 1a1017 192.168.10.3 1324 X.25 BX.25 DCP MPDM C-LAN TN799 PktInt TN1655 342C-LAN TN799 software-defined connections