Here you can view all the pages of manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Administration For Network Connectivity Instructions Manual. The Lucent Technologies manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 121
Configuration 3:R8si R8r Gateway R8si 101 Administration for Network Connectivity 555-233-504— Issue 1 — April 2000 CID: 77730 3 C-LAN Administration Switch 1 Task — Assign Node Names This task assigns node names and IP addresses to each node in the network. This screen is administered on Switch 1. A Node Names screen must be administered on each switch in the network. A node is defined as any of the following — a C-LAN port, a bridge or router, a CMS ethernet port, or an Intuity AUDIX or other...
Page 122
Configuration 3:R8si R8r Gateway R8si 3 C-LAN Administration Administration for Network Connectivity CID: 77730 555-233-504 — Issue 1 — April 2000 102 Switch 1 Task — Assign pdm Data Module This task administers a pdm data module for the connection between the PGATE board and the DS1 board for the connection to node-2. The data module associates a link number with a port address and extension number for the PGATE port used for this connection. Begin Steps > Open the Data Module form — enter a da...
Page 123
Configuration 3:R8si R8r Gateway R8si 103 Administration for Network Connectivity 555-233-504— Issue 1 — April 2000 CID: 77730 3 C-LAN Administration Secondary data modules?Enter n. Connected To Enter dte. Keep the default values for the rest of the fields. Field Conditions/Comments 2 of 2
Page 124
Configuration 3:R8si R8r Gateway R8si 3 C-LAN Administration Administration for Network Connectivity CID: 77730 555-233-504 — Issue 1 — April 2000 104 Switch 1 Task — Assign Link via x.25 Data Module to Switch 2 This task administers an x.25 data module for the connection to node 2. The data module associates a link number with a port address and extension number for the PGATE port used for this connection. Begin Steps > If a PGATE circuit pack is not already administered in slot 1c01, insert the...
Page 125
Configuration 3:R8si R8r Gateway R8si 105 Administration for Network Connectivity 555-233-504— Issue 1 — April 2000 CID: 77730 3 C-LAN Administration > Submit the screen End Name:Information-only; appears in list generated by the “list data module” command. COS: The values for these fields will be specified by the system administrator. COR: TN: DTE/DCE: The DTE/DCE assignments must be opposites on the two ends of the connection. Use dce for node 2. Enable Link? Set to y after the processor...
Page 126
Configuration 3:R8si R8r Gateway R8si 3 C-LAN Administration Administration for Network Connectivity CID: 77730 555-233-504 — Issue 1 — April 2000 106 Switch 1 Task — Assign IP Interfaces The IP interface for each C-LAN board on the switch must be defined on the IP Interfaces form. Each DEFINITY switch in an IP network has one IP Interfaces form. Begin Steps > Open IP Interfaces form — enter ch ip-i > Enter values change ip-interfaces Page 1 of 2 IP Interfaces Inter-region IP connectivity...
Page 127
Configuration 3:R8si R8r Gateway R8si 107 Administration for Network Connectivity 555-233-504— Issue 1 — April 2000 CID: 77730 3 C-LAN Administration Subnet Mask Enter the subnet mask associated with the IP address for this IP interface. (The IP address is associated with the node name on the Node Names screen). In this example, leave the default subnet mask, 255.255.255.0, which indicates no subnetting for a Class C IP address. See the discussion of subnetting, Subnetting (page 16), in...
Page 128
Configuration 3:R8si R8r Gateway R8si 3 C-LAN Administration Administration for Network Connectivity CID: 77730 555-233-504 — Issue 1 — April 2000 108 Switch 1 Task — Assign Link via ethernet Data Module to the LAN This task administers an ethernet data module for ethernet connections. The data module associates a link number with a port address, extension number, and node name for the C-LAN port used for this connection. Begin Steps > Open Data Module form — enter a da n > Enter values. > Submit...
Page 129
Configuration 3:R8si R8r Gateway R8si 109 Administration for Network Connectivity 555-233-504— Issue 1 — April 2000 CID: 77730 3 C-LAN Administration Switch 1 Task — Assign Processor Channels This task associates data links (hardware) with processor channels (software) on the node-1 switch. Begin Steps> > Open Processor Channel Assignment form — enter ch com p Note:The Processor Channel number, the Interface Channel number, and the Local and Remote Session numbers do not need to be the same number...
Page 130
Configuration 3:R8si R8r Gateway R8si 3 C-LAN Administration Administration for Network Connectivity CID: 77730 555-233-504 — Issue 1 — April 2000 110 Session - Local The Local and Remote Session numbers can be any value between 1 and 256 (si model) or 384 (r model), but they must be consistent between endpoints. For each connection, the Local Session number on this switch must equal the Remote Session number on the remote switch and vice versa. It is allowed, and sometimes convenient, to use the...