Here you can view all the pages of manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Administration For Network Connectivity Instructions Manual. The Lucent Technologies manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 121

Configuration 3:R8si R8r Gateway 
 R8si 
101
Administration for Network Connectivity
555-233-504— Issue 1 — April 2000 CID: 77730
3  C-LAN Administration
Switch 1 Task — Assign Node Names
This task assigns node names and IP addresses to each node in the network. This 
screen is administered on Switch 1. A Node Names screen must be administered on 
each switch in the network.
A node is defined as any of the following — a C-LAN port, a bridge or router, a CMS 
ethernet port, or an Intuity AUDIX or other...

Page 122

Configuration 3:R8si R8r Gateway 
 R8si 3  C-LAN Administration
Administration for Network Connectivity
CID: 77730 555-233-504 — Issue 1 — April 2000
102
Switch 1 Task — Assign pdm Data Module
This task administers a pdm data module for the connection between the PGATE 
board and the DS1 board for the connection to node-2. The data module associates a 
link number with a port address and extension number for the PGATE port used for 
this connection.
Begin
Steps
> Open the Data Module form — enter  a da...

Page 123

Configuration 3:R8si R8r Gateway 
 R8si 
103
Administration for Network Connectivity
555-233-504— Issue 1 — April 2000 CID: 77730
3  C-LAN Administration
Secondary data 
modules?Enter n.
Connected To Enter 
dte.
Keep the default values for the rest of the fields. Field Conditions/Comments
2 of 2 

Page 124

Configuration 3:R8si R8r Gateway 
 R8si 3  C-LAN Administration
Administration for Network Connectivity
CID: 77730 555-233-504 — Issue 1 — April 2000
104
Switch 1 Task — Assign Link via x.25 Data Module to Switch 2
This task administers an x.25 data module for the connection to node 2. The data 
module associates a link number with a port address and extension number for the 
PGATE port used for this connection.
Begin
Steps
> If a PGATE circuit pack is not already administered in slot 1c01, insert the...

Page 125

Configuration 3:R8si R8r Gateway 
 R8si 
105
Administration for Network Connectivity
555-233-504— Issue 1 — April 2000 CID: 77730
3  C-LAN Administration
> Submit the screen
End
Name:Information-only; appears in list generated by the “list data 
module” command.
COS:
The values for these fields will be specified by the system 
administrator. COR:
TN:
DTE/DCE: The DTE/DCE assignments must be opposites on the two ends 
of the connection. Use dce for node 2.
Enable Link? Set to y after the processor...

Page 126

Configuration 3:R8si R8r Gateway 
 R8si 3  C-LAN Administration
Administration for Network Connectivity
CID: 77730 555-233-504 — Issue 1 — April 2000
106
Switch 1 Task — Assign IP Interfaces
The IP interface for each C-LAN board on the switch must be defined on the IP 
Interfaces form. Each DEFINITY switch in an IP network has one IP Interfaces form.
Begin
Steps
> Open IP Interfaces form — enter  ch ip-i
> Enter values
change ip-interfaces  Page   1 of   2 
IP Interfaces
Inter-region IP connectivity...

Page 127

Configuration 3:R8si R8r Gateway 
 R8si 
107
Administration for Network Connectivity
555-233-504— Issue 1 — April 2000 CID: 77730
3  C-LAN Administration
Subnet Mask Enter the subnet mask associated with the IP address for 
this IP interface. (The IP address is associated with the 
node name on the Node Names screen). 
In this example, leave the default subnet mask, 
255.255.255.0, which indicates no subnetting for a Class 
C IP address.
See the discussion of subnetting, Subnetting  (page 16), in...

Page 128

Configuration 3:R8si R8r Gateway 
 R8si 3  C-LAN Administration
Administration for Network Connectivity
CID: 77730 555-233-504 — Issue 1 — April 2000
108
Switch 1 Task — Assign Link via ethernet Data Module to the LAN
This task administers an ethernet data module for ethernet connections. The data 
module associates a link number with a port address, extension number, and node 
name for the C-LAN port used for this connection.
Begin
Steps
> Open Data Module form — enter  a da n 
> Enter values.
> Submit...

Page 129

Configuration 3:R8si R8r Gateway 
 R8si 
109
Administration for Network Connectivity
555-233-504— Issue 1 — April 2000 CID: 77730
3  C-LAN Administration
Switch 1 Task — Assign Processor Channels
This task associates data links (hardware) with processor channels (software) on the 
node-1 switch.
Begin
Steps>
> Open Processor Channel Assignment form — enter  ch com p
Note:The Processor Channel number, the Interface Channel number, and the 
Local and Remote Session numbers do not need to be the same number...

Page 130

Configuration 3:R8si R8r Gateway 
 R8si 3  C-LAN Administration
Administration for Network Connectivity
CID: 77730 555-233-504 — Issue 1 — April 2000
110
Session - Local The Local and Remote Session numbers can be any value 
between 1 and 256 (si model) or 384 (r model), but they must 
be consistent between endpoints. For each connection, the 
Local Session number on this switch must equal the Remote 
Session number on the remote switch and vice versa.