Here you can view all the pages of manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Administration For Network Connectivity Instructions Manual. The Lucent Technologies manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 91

Configuration 1: R8r  R8si 
71
Administration for Network Connectivity
555-233-504— Issue 1 — April 2000 CID: 77730
3  C-LAN Administration
> Submit the screen
End
Session - Local The Local and Remote Session numbers can be any value 
between 1 and 256 (si model) or 384 (r model), but they must 
be consistent between endpoints. For each connection, the 
Local Session number on this switch must equal the Remote 
Session number on the remote switch and vice versa.
It is allowed, and sometimes convenient,...

Page 92

Configuration 1: R8r  R8si 3  C-LAN Administration
Administration for Network Connectivity
CID: 77730 555-233-504 — Issue 1 — April 2000
72
Enable links and processor channels
You must enable links and processor channels before the connections can be used.
To enable a link, open its data module screen (ch da [ext]) and set the Enable 
Link? field to y. 
[note: to view a list of assigned data modules and their extensions, enter the “list 
data-module” command (l da)]
To enable the processor channels, open...

Page 93

Configuration 2: R7r (+CMS)  R7csi 
73
Administration for Network Connectivity
555-233-504— Issue 1 — April 2000 CID: 77730
3  C-LAN Administration
Configuration 2: R7r (+CMS)  R7csi 
This configuration is a 10BaseT ethernet connection between a DEFINITY ECS R8r 
and a DEFINITY ECS R8csi switch in a DCS network, which includes routers 
between the switches. The R8r is connected to a CMS adjunct (the DEFINITY 
administration for Intuity AUDIX would be similar) via the LAN. 
Note:This network has 5 IP...

Page 94

Configuration 2: R7r (+CMS)  R7csi 3  C-LAN Administration
Administration for Network Connectivity
CID: 77730 555-233-504 — Issue 1 — April 2000
74
Task Summary
The following tasks need to be completed for Switch 1 and Switch 2:
1  Review prerequisite administration checklist
2  Switch 1 administration
 a  Assign node names
 b  Assign IP Interfaces
 c  Assign link (via a data module) to the LAN
 d  Assign processor channels
3  Switch 2 administration
 a  Enable bus bridge connectivity
 b  Assign node...

Page 95

Configuration 2: R7r (+CMS)  R7csi 
75
Administration for Network Connectivity
555-233-504— Issue 1 — April 2000 CID: 77730
3  C-LAN Administration
SWITCH 1Configuration 2
DEFINITY ECS R8rDEFINITY ECS R8csi
Processor
channelsProcessor
channelsInterface
channelsInterface
channels
1
2
12
3841
5000
5001
x(any)
645001
2
21
256
Link 2Link 5
1
5000
5001
5003
64500
SWITCH 2
hardware connectionsProcessor
UN331B
Processor bus
TDM bus
Packet bus
DS1
TN767/
TN464
C-LAN
TN799
Voice data
Ethernet
dataNetwork
control...

Page 96

Configuration 2: R7r (+CMS)  R7csi 3  C-LAN Administration
Administration for Network Connectivity
CID: 77730 555-233-504 — Issue 1 — April 2000
76
Switch 1 Task — Assign Node Names
This task assigns node names and IP addresses to each node in the network. This 
screen is administered on Switch 1. A Node Names screen must be administered on 
each switch in the network.
The node names and IP addresses in any network should be assigned in a logical and 
consistent manner from the point of view of the whole...

Page 97

Configuration 2: R7r (+CMS)  R7csi 
77
Administration for Network Connectivity
555-233-504— Issue 1 — April 2000 CID: 77730
3  C-LAN Administration
Switch 1 Task — Assign IP Interfaces
The IP interface for each C-LAN and MedPro board on the switch must be defined on 
the IP Interfaces form. Each DEFINITY switch in an IP network has one IP Interfaces 
form.
Begin
Steps
> Open IP Interfaces form — enter  ch ip-i
> Enter values
change ip-interfaces  Page   1 of   2 
IP Interfaces
Inter-region IP...

Page 98

Configuration 2: R7r (+CMS)  R7csi 3  C-LAN Administration
Administration for Network Connectivity
CID: 77730 555-233-504 — Issue 1 — April 2000
78
> Submit the screen
End
Subnet Mask Enter the subnet mask associated with the IP address for this IP 
interface. 
The IP address for node-1, specified on the Node Names screen, 
is 192.168.1.124. The 192 in the first octet puts this address in 
the range of “Class C” addresses, which means the first 3 octets 
are used for the network ID and the fourth octet...

Page 99

Configuration 2: R7r (+CMS)  R7csi 
79
Administration for Network Connectivity
555-233-504— Issue 1 — April 2000 CID: 77730
3  C-LAN Administration
Switch 1 Task — Assign Link via ethernet Data Module to the LAN  
This task administers an ethernet data module for the ethernet connection to the CMS 
adjunct and to Switch 2. The data module defines a network interface — it associates 
a link number with a port address and node name for the C-LAN port used for this 
connection.
Begin
Steps
> Open Data...

Page 100

Configuration 2: R7r (+CMS)  R7csi 3  C-LAN Administration
Administration for Network Connectivity
CID: 77730 555-233-504 — Issue 1 — April 2000
80
Switch 1 Task — Assign Processor Channels
This task associates data links (hardware) with processor channels (software) on the 
node 1 switch. 
Begin
Steps
> Open the Processor Channel Assignment form — enter  ch com p
> Enter values
change communications-interface processor-channels
                                                                    Page 1...