Here you can view all the pages of manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Administration For Network Connectivity Instructions Manual. The Lucent Technologies manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 111

Configuration 2: R7r (+CMS)  R7csi 
91
Administration for Network Connectivity
555-233-504— Issue 1 — April 2000 CID: 77730
3  C-LAN Administration
Destination 
NodeName of the far-end node for this channel. This must be a 
name entered on the Node Names screen. 
Destination Port A value of 0 allows any available interface channel on the 
destination node to be used for this connection. The Interface 
Channel number on the Switch-2 Processor Channel screen 
must also be set to 0.
Session - Local The...

Page 112

Configuration 2: R7r (+CMS)  R7csi 3  C-LAN Administration
Administration for Network Connectivity
CID: 77730 555-233-504 — Issue 1 — April 2000
92
> Submit the screen
End
Intuity System Administration
Procedure OverviewThe following is a checklist of procedures that must be completed to administer a 
DEFINITY ECS with a TCP/IP connection to a Lucent Intuity system. The 
DEFINITY administration procedures are described in DEFINITY ECS 
Administrator’s Guide, 555-233-502 and in previous sections of this...

Page 113

Configuration 2: R7r (+CMS)  R7csi 
93
Administration for Network Connectivity
555-233-504— Issue 1 — April 2000 CID: 77730
3  C-LAN Administration
•Apply the coverage path to stations, and if the switch is an r model, specify the 
node name of the Intuity system for each station that has a voice mailbox on the 
Intuity system.
Intuity system administration
The following procedures must be done on the Intuity system:
•Administer the UNIX name and IP address for the Intuity system.
•Administer the switch...

Page 114

Configuration 2: R7r (+CMS)  R7csi 3  C-LAN Administration
Administration for Network Connectivity
CID: 77730 555-233-504 — Issue 1 — April 2000
94
Administer the Switch 
InterfaceYou must now administer the switch interface. Do the following.
1  Starting at the Lucent INTUITY Main menu, select:
The system responds with the Switch Interface Administration window.
2  Use Worksheet B to enter the correct values in this window.
3  Press F3 (Save).
4  Continue with the next procedure, “Administer Extension...

Page 115

Configuration 2: R7r (+CMS)  R7csi 
95
Administration for Network Connectivity
555-233-504— Issue 1 — April 2000 CID: 77730
3  C-LAN Administration
Administer Subscribers
Subscribers must be administered on the Intuity system. For more information on this, 
see the Lucent I
NTUITY Messaging Solutions Release 5 documentation. The following 
screens show examples of subscriber screens on the Intuity system.
add subscriber 3066 Page 1 of 2
                                 SUBSCRIBER
         Name: Jean...

Page 116

Configuration 2: R7r (+CMS)  R7csi 3  C-LAN Administration
Administration for Network Connectivity
CID: 77730 555-233-504 — Issue 1 — April 2000
96
Worksheet A: Names and IP Addresses for Lucent Intuity System
Complete the information on this worksheet to collect information required to 
administer the Lucent I
NTUITY system for integration with the switch.
Field Recommended Your Entry
Intuity System TCP/IP Administration Screen (TCP/IP Administration, Network 
Addressing or Networking Administration,...

Page 117

Configuration 2: R7r (+CMS)  R7csi 
97
Administration for Network Connectivity
555-233-504— Issue 1 — April 2000 CID: 77730
3  C-LAN Administration
Worksheet B: LAN Data for the Lucent Intuity System
Complete the information on this worksheet to administer the Lucent INTUITY system 
for integration with the switch.
Field Recommended Your Entry
Lucent INTUITY System Switch Interface Administration Window
Extension Length
Use the extension length from the switch dial 
plan
4
Host Switch Number
Use 1 if the...

Page 118

Configuration 2: R7r (+CMS)  R7csi 3  C-LAN Administration
Administration for Network Connectivity
CID: 77730 555-233-504 — Issue 1 — April 2000
98
Enable links and processor channels
You must enable links and processor channels before the connections can be used.
To enable a link, open its data module screen (ch da [ext]) and set the Enable 
Link? field to y. 
[note: to view a list of assigned data modules and their extensions, enter the “list 
data-module” command (l da)]
To enable the processor...

Page 119

Configuration 3:R8si R8r Gateway 
 R8si 
99
Administration for Network Connectivity
555-233-504— Issue 1 — April 2000 CID: 77730
3  C-LAN Administration
Configuration 3:R8si R8r Gateway  R8si 
In this configuration, a DEFINITY ECS R8r acts as a gateway between two other 
nodes — one connected via X.25 to an R8si and the other via ethernet to another R8si.
Task Summary
The following tasks need to be completed for Switch 1, Switch 2, and Switch 3:
1  Review checklist
2  Switch 1 administration
 a  Assign...

Page 120

Configuration 3:R8si R8r Gateway 
 R8si 3  C-LAN Administration
Administration for Network Connectivity
CID: 77730 555-233-504 — Issue 1 — April 2000
100
Prerequisite Administration
There are some system administration tasks that need to be completed before you can 
proceed with the connectivity administration described in this section.
Review the checklist of prerequisite administration tasks in Checklist for Prerequisite 
Administration  (page 54), before proceeding with the connectivity administration...