Here you can view all the pages of manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Administration For Network Connectivity Instructions Manual. The Lucent Technologies manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 181

Configuration 5A: R8csi  R8r (one C-LAN) 
 R8si 
161
Administration for Network Connectivity
555-233-504— Issue 1 — April 2000 CID: 77730
3  C-LAN Administration
Switch 2 Task — Assign Processor Channels
This task associates data links (hardware) with processor channels (software) on the 
Switch 2.
Begin
Steps
> Open the Processor Channel Assignment form — enter  ch com p
> Enter values
change communications-interface processor-channels...

Page 182

Configuration 5A: R8csi  R8r (one C-LAN) 
 R8si 3  C-LAN Administration
Administration for Network Connectivity
CID: 77730 555-233-504 — Issue 1 — April 2000
162
> Submit the screen
End
Session - Local The Local and Remote Session numbers can be any value 
between 1 and 256 (si model) or 384 (r model), but they 
must be consistent between endpoints. For each 
connection, the Local Session number on this switch must 
equal the Remote Session number on the remote switch 
and vice versa.
It is allowed, and...

Page 183

Configuration 5A: R8csi  R8r (one C-LAN) 
 R8si 
163
Administration for Network Connectivity
555-233-504— Issue 1 — April 2000 CID: 77730
3  C-LAN Administration
Switch 2 Task — Assign IP Route to node-3
This task specifies an initial route for messages handled by node-2 that are destined 
for node-3. An IP route is required for this route because there are intermediate nodes 
between node-2 and node-3.
Begin
Steps
> Enable the ppp link on the node-2 data module screen: 
ch da 3020, set Enable Link? to...

Page 184

Configuration 5A: R8csi  R8r (one C-LAN) 
 R8si 3  C-LAN Administration
Administration for Network Connectivity
CID: 77730 555-233-504 — Issue 1 — April 2000
164
Switch 3 Task — Assign Node Names
This task assigns node names and IP addresses to each node in the network. This 
screen is administered on Switch 3. A Node Names screen must be administered on 
each switch in the network.
The node names and IP addresses in any network should be assigned in a logical and 
consistent manner from the point of...

Page 185

Configuration 5A: R8csi  R8r (one C-LAN) 
 R8si 
165
Administration for Network Connectivity
555-233-504— Issue 1 — April 2000 CID: 77730
3  C-LAN Administration
Switch 3 Task — Assign IP Interfaces
The IP interface for each C-LAN board on the switch must be defined on the IP 
Interfaces form. Each DEFINITY switch in an IP network has one IP Interfaces form.
Begin
Steps
> Open IP Interfaces form — enter  ch ip-i
> Enter values
change ip-interfaces  Page   1 of   2 
IP Interfaces
Inter-region IP...

Page 186

Configuration 5A: R8csi  R8r (one C-LAN) 
 R8si 3  C-LAN Administration
Administration for Network Connectivity
CID: 77730 555-233-504 — Issue 1 — April 2000
166
Subnet Mask Enter the subnet mask associated with the IP address for 
this IP interface. (The IP address is associated with the 
node name on the Node Names screen). 
In this example, leave the default subnet mask, 
255.255.255.0, which indicates no subnetting for a Class 
C IP address.
See the discussion of subnetting, Subnetting  (page 16), in...

Page 187

Configuration 5A: R8csi  R8r (one C-LAN) 
 R8si 
167
Administration for Network Connectivity
555-233-504— Issue 1 — April 2000 CID: 77730
3  C-LAN Administration
Switch 3 Task — Assign Link via ethernet Data Module to the LAN
This task administers an ethernet data module on Switch 3 for the ethernet 
connection. The data module associates a link number with a port address, extension 
number, and node name for the C-LAN port used for this connection.
Begin
Steps
> Open Data Module form — enter  a da n
>...

Page 188

Configuration 5A: R8csi  R8r (one C-LAN) 
 R8si 3  C-LAN Administration
Administration for Network Connectivity
CID: 77730 555-233-504 — Issue 1 — April 2000
168
Switch 3 Task — Assign Processor Channels
This task associates data links with processor channels on Switch 3.
Begin
Steps
> Open the Processor Channel Assignment form — enter  ch com p
> Enter values
change communications-interface processor-channels
                                                                    Page 1 of X
PROCESSOR...

Page 189

Configuration 5A: R8csi  R8r (one C-LAN) 
 R8si 
169
Administration for Network Connectivity
555-233-504— Issue 1 — April 2000 CID: 77730
3  C-LAN Administration
> Submit the screen
End
Session - Local The Local and Remote Session numbers can be any value 
between 1 and 256 (si model) or 384 (r model), but they must be 
consistent between endpoints. For each connection, the Local 
Session number on this switch must equal the Remote Session 
number on the remote switch and vice versa.
It is allowed, and...

Page 190

Configuration 5A: R8csi  R8r (one C-LAN) 
 R8si 3  C-LAN Administration
Administration for Network Connectivity
CID: 77730 555-233-504 — Issue 1 — April 2000
170
Enable links and processor channels
You must enable links and processor channels before the connections can be used.
To enable a link, open its data module screen (ch da [ext]) and set the Enable 
Link? field to y. 
[note: to view a list of assigned data modules and their extensions, enter the “list 
data-module” command (l da)]
To enable the...