Here you can view all the pages of manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Administration For Network Connectivity Instructions Manual. The Lucent Technologies manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 201

Configuration 5B:R8csi  R8r (2 C-LANs) 
 R8si 
181
Administration for Network Connectivity
555-233-504— Issue 1 — April 2000 CID: 77730
3  C-LAN Administration
> Submit the screen
End
COS
The values for these fields will be specified by the system 
administrator. COR:
TN:
Node Name: The node name for the interface defined by this data module. 
This must be a name entered on the Node Names screen.
Subnet Mask:
Establish 
Connection?n means that the node at the remote end of this connection 
(node-1b in...

Page 202

Configuration 5B:R8csi  R8r (2 C-LANs) 
 R8si 3  C-LAN Administration
Administration for Network Connectivity
CID: 77730 555-233-504 — Issue 1 — April 2000
182
Switch 1 Task — Assign Link via ppp Data Module to C-LAN(b)
This task administers a ppp data module on Switch 1 for the ppp connection from the 
C-LAN(a) circuit pack to the C-LAN(b) circuit pack. 
Begin
Steps
> 
Open Data Module form — enter ad da 2013
> Enter values
add data-module 2013...

Page 203

Configuration 5B:R8csi  R8r (2 C-LANs) 
 R8si 
183
Administration for Network Connectivity
555-233-504— Issue 1 — April 2000 CID: 77730
3  C-LAN Administration
> Submit the screen
End
COS
The values for these fields will be specified by the system 
administrator. COR:
TN:
Node Name: The node name for the interface defined by this data 
module. This must be a name entered on the Node Names 
screen.
Subnet Mask:
Establish 
Connection?y means that this node is responsible for the call setup for 
the link to...

Page 204

Configuration 5B:R8csi  R8r (2 C-LANs) 
 R8si 3  C-LAN Administration
Administration for Network Connectivity
CID: 77730 555-233-504 — Issue 1 — April 2000
184
Switch 1 Task — Assign Processor Channels
This task associates data links (hardware) with processor channels (software) on 
Switch 1. Note that there are no processor channels or interface channels associated 
with the ppp connection between the two C-LAN circuit packs.
Begin
Steps
> Open the Processor Channel Assignment form — enter  ch com p.
>...

Page 205

Configuration 5B:R8csi  R8r (2 C-LANs) 
 R8si 
185
Administration for Network Connectivity
555-233-504— Issue 1 — April 2000 CID: 77730
3  C-LAN Administration
Destination Node Name of the far-end node for this channel. This must be a 
name entered on the Node Names screen. For ppp 
connections, it must match the Destination Node Name 
entered on the ppp Data Module screen.
Destination Port A value of 0 allows any available interface channel on the 
destination node to be used for this connection. The...

Page 206

Configuration 5B:R8csi  R8r (2 C-LANs) 
 R8si 3  C-LAN Administration
Administration for Network Connectivity
CID: 77730 555-233-504 — Issue 1 — April 2000
186
> Submit the screen
End
Session - Local For each connection, the Local Session number on this switch 
must equal the Remote Session number on the remote switch 
and vice versa. Session - Remote
Mach ID Destination switch ID identified on the dial plan of the 
destination switch. Field Conditions/Comments
3 of 3 

Page 207

Configuration 5B:R8csi  R8r (2 C-LANs) 
 R8si 
187
Administration for Network Connectivity
555-233-504— Issue 1 — April 2000 CID: 77730
3  C-LAN Administration
Switch 1 Task — Assign IP Route: C-LAN(a) to node-3
This task specifies a route for packets handled by C-LAN(a) destined for node-3. This 
route is needed because node-1a and node-3 are connected via ppp and there are 
intermediate nodes between them.
Begin
Steps
> Enable the ppp link on the node-1a data module screen: 
ch da 2013, set Enable...

Page 208

Configuration 5B:R8csi  R8r (2 C-LANs) 
 R8si 3  C-LAN Administration
Administration for Network Connectivity
CID: 77730 555-233-504 — Issue 1 — April 2000
188
Switch 1 Task — Assign IP Route: C-LAN(b) to node-2
This task specifies a route for packets handled by C-LAN(b) destined for node-2. This 
route is needed because node-1b and node-2 are connected via ppp and there are 
intermediate nodes between them.
Begin
Steps
> Enable the ppp link on the node-1b data module screen: 
ch da 2378, set Enable...

Page 209

Configuration 5B:R8csi  R8r (2 C-LANs) 
 R8si 
189
Administration for Network Connectivity
555-233-504— Issue 1 — April 2000 CID: 77730
3  C-LAN Administration
Switch 2 Task — Enable Bus Bridge Connectivity
This task enables the bus bridge functionality on the C-LAN circuit pack to provide a 
path between the packet bus and the processor.
Note:Bus Bridge Connectivity is used on the csi model only. This task may 
have been complete when the C-LAN circuit pack was installed.
Begin
Steps
> Open the...

Page 210

Configuration 5B:R8csi  R8r (2 C-LANs) 
 R8si 3  C-LAN Administration
Administration for Network Connectivity
CID: 77730 555-233-504 — Issue 1 — April 2000
190
Switch 2 Task — Assign Node Names
This task assigns node names and IP addresses to each node in the network. This 
screen is administered on Switch 2. A Node Names screen must be administered on 
each switch in the network.
The node names and IP addresses in any network should be assigned in a logical and 
consistent manner from the point of view...
Start reading Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Administration For Network Connectivity Instructions Manual

Related Manuals for Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Administration For Network Connectivity Instructions Manual

All Lucent Technologies manuals