Have a look at the manual Lucent Technologies Definity Audix System Release 4.0 Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
Planning for the DEFINITY AUDIX System Release 4.0 585-300-602 Issue 1 May 1999 Overview 1-3 Compatible Switches and Software 1 Transmission Control Protoc ol/Internet Protoc ol (TCP/IP) c onnec tion into the system. Up to 32 sub scrib ers can b e log g ed into the system at any one time using I NTUITY Messag e Manag er. Compatible Switches and Software The DEFINITY AUDIX system c an b e installed in the following switc hes: nSystem 75 R1V3, System 75 R1V3n nSystem 75 XE nDEFINITY Communic ations System Generic 1 nDEFINITY Communic ations System Generic 3i nDEFINITY Communic ations System Generic 3s nDEFINITY Communic ations System Generic 3si nDEFINITY Communic ation System Generic 3c si (ProLogix) nDEFINITY Communic ations System Generic 3vs nDEFINITY Communic ations System Generic 3r
Planning for the DEFINITY AUDIX System Release 4.0 585-300-602 Issue 1 May 1999 Overview 1-4 Compatible Switches and Software 1 Not all software releases for these switc hes are c omp atib le with the DEFINITY AUDIX system Release 4.0. Tab le 1-1 lists the switches and switc h software load s that are c omp atible with the DEFINITY AUDIX system. Customers with switc h software releases b elow those spec ified in Tab le 1-1 must up g rad e their switc h software to ac c ommod ate the DEFINITY AUDIX system Table 1-1. Switches and Switch Software Releases Compatible with the DEFINITY AUDIX System SwitchDo these Software Releases Support the System in Native Mode? System 75 1 n Release 1 Version 3n Release 1 Version 3n 1. MFATs c annot be used to ac c ess the DEFINITY AUDIX system with DEFINITY switc h Release 5.3. Use of MFATs with the DEFINITY AUDIX system is sup ported in all software releases ab ove 5.3.No No G1 n G1.1n G1.1nNo No G3vs 2 n Version 1 to Version 4 n Release 5 to Release 6No No G3s 2 n Version 1 to Version 3 2. The Transfer Out of AUDIX feature is not supp orted on these switc hes p rior to G3V2g .04.5.0.099.No G3i 2 n Version 1 to Version 3 No G3si n Version 4 n Release 5 to Release 6No No G3si n Release 7 or higher Yes G3csi n Release 6 No G3csi n Release 7 or higher Yes G3r n Version 1 to Version 4 n Release 53 to Release 6 3. These switc h releases d o not sup p ort the use of multifunc tion analog telep hones (MFATs) with the DEFINITY AUDIX system. The DEFINITY G3r switc h sup p orts MFATs in all releases ab ove 5.3.No No G3r n Release 7 or higher Yes
Planning for the DEFINITY AUDIX System Release 4.0 585-300-602 Issue 1 May 1999 Overview 1-5 DEFINITY AUDIX Planning 1 Luc ent Tec hnolog ies also rec ommend s that c ustomers up g rad e to the latest software issue for their switc h releases. DEFINITY AUDIX Planning In p lanning and imp lementing a DEFINITY AUDIX installation, the c ustomer and Luc ent Tec hnolog ies emp loyees must c oord inate their efforts for the need s assessment/c ontrac t, p re-installation, installation, and post-installation ac tivities. The following chapters c ontain an overview of the tasks that must be performed d uring eac h of these p hases. Throug hout the imp lementation p roc ess, the Luc ent Tec hnolog ies p rojec t manag er should b e the c ustomers sing le p oint of c ontac t. If the c ustomer need s assistanc e with the DEFINITY AUDIX system after the c utover is c omp lete and the system is ac c ep ted, the c ustomer should c ontac t the ap p rop riate servic e org anization: nCustomers in the U.S. should c ontac t the TSC at 1-800-242-2121. nCustomers outsid e the U.S. should c ontac t their COEs. Table 1-2. Voice Port Limits Switch TypeMaximum Number of Voice Ports with Digital NetworkingMaximum Number of Voice Ports without Digital Networking All c omp atib le switc hes 8 12
Planning for the DEFINITY AUDIX System Release 4.0 585-300-602 Issue 1 May 1999 Overview 1-6 DEFINITY AUDIX Planning 1
New System Ordered with New Switch 2-1 2 Planning for the DEFINITY AUDIX System Release 4.0 585-300-602 Issue 1 May 1999 2 New System Ordered with New Switch Tab le 2-1 is a c hec klist that summarizes the tasks req uired for p lanning and installing the DEFINITY AUDIX system when it is ord ered with a new switc h. The c hec klist is d esig ned to help all p arties involved c oordinate their p lanning and imp lementation ac tivities. Where it is ap p rop riate, tasks refer to d oc uments that c ontain more detailed instruc tions or information. The symbol Ü in the c hec klist p oints to a worksheet in the ap pend ixes that should b e filled in at that p oint in the p lanning p roc ess. Tab le 2-1 is d esig ned to b e used in c onjunc tion with the AUDIX Streamlined Imp lementation p roc ess flow. For more d etailed information on DEFINITY AUDIX implementation, see the binders produced for AUDIX Streamlined Imp lementation. These b ind ers should b e in eac h Luc ent Tec hnologies b ranc h offic e. For switc h imp lementation tasks, c onsult the b ind ers p rod uc ed for Streamlined Imp lementation and the ap p rop riate switc h p lanning doc ument.
Planning for the DEFINITY AUDIX System Release 4.0 585-300-602 Issue 1 May 1999 New System Ordered with New Switch 2-2 2 Table 2-1. New System with New Switch Task Party RequirementsDate Complete Performing Assessment and Contract Tasks Comp lete need s assessmentAcc ount executiveDetermine the ap p rop riate voic e messag ing and software ap plication solution for the c ustomer. If a DEFINITY AUDIX system is the b est solution, determine the ap p roximate numb er of voice p orts, hours of voice storag e, and PC software app lic ations the customer need s. For further information ab out DEFINITY AUDIX c ap acity and sizing, see DEFINITY A U D IX Sys te m — Sys t em D e s c r i p ti o n , 585-300-214. If the DEFINITY AUDIX system will b e used as a server for I NTUITY Message Manag er over a local area network (LAN), work with the c ustomer’s LAN administrator to set up a d emarcation point on the wallfield . This p oint must be within 25 feet from the b ac k of the switc h. A 10BaseT connection is need ed . Lucent Technolog ies p rovid es a 104A mounting b lock as the d emarcation p oint on the wall for this c onnection to p lug into. Luc ent Technologies also p rovides a D8W mod ular wall c ord to make the c onnection b etween the mounting block and DEFINITY AUDIX ad ap ter cable. ÜFi ll i n Worksheet C-2 to id entify the eq uip ment needed for I NTUITY Messag e Manag er. ÜDetermine whether the c ustomer will use AMIS Analog or Digital Networking . Fill out Worksheet D-1. For more information ab out the system’s req uirements for AMIS Analog and Dig ital Networking , see DEFINITY AUDIX System Release 4.0 — System Desc rip tion , 585-300-214. Determine what primary and sec ond ary Multiling ual announcement sets will b e used . Continued on next page
Planning for the DEFINITY AUDIX System Release 4.0 585-300-602 Issue 1 May 1999 New System Ordered with New Switch 2-3 2 ÜFill in Wo r k s h e e t C - 1 and Wo r k s h e e t C - 7 to ac tivate the Multiling ual op tion and Worksheet C-8 to spec ify lang uag e sets. Id entify any p erip heral eq uip ment the c ustomer need s, includ ing terminals, modems, and c ables not inc lud ed with the DEFINITY AUDIX system PEC. ÜFill in Wo r k s h e e t E- 1. Generate a config urationAcc ount executive or design sp ec ialistSee DEFINITY AUDIX System — System Description, 585-300-214 for detailed information ab out the DEFINITY AUDIX system. ÜIf the c ustomer wants to use Dig ital Networking , comp lete form 1154 in Ap pendix H. Review equipment room req uirementsPro j ec t manag er or account executiveSee DEFINITY AUDIX System — System Description, 585-300-214 for detailed information ab out environmental c onsid erations. Review the eq uip ment room’s environmental req uirements with the customer and ob tain the c ustomers signature. Preparing for Installation Ord er d oc umentationAcc ount executiveIf the c ustomer wants d ocumentation to arrive b efore the DEFINITY AUDIX system, order it at this time, or any time b efore you p lac e the ord er for the system. Table 2-1. New System with New Switch (Continued) Task Party RequirementsDate Complete Continued on next page
Planning for the DEFINITY AUDIX System Release 4.0 585-300-602 Issue 1 May 1999 New System Ordered with New Switch 2-4 2 The CD-ROM, DEFINITY AUDIX System Release 4.0 Documents , 585-300-803, includes the following doc umentation: Planning for the DEFINITY AUDIX System Release 4.0 , 585-300-602 D EFI N I TY A U D I X Sy st e m — Sy st e m Description , 585-300-214 DEFINITY AUDIX System — Feature Descriptions , 585-300-206 BCS Prod uct Security Hand book, 555-025-600 DEFINITY AUDIX System — Ad ministration, 585-300-507 DEFINITY AUDIX System Release 4.0 — Sc reens Referenc e , 585-300-213 Installation and Switc h Administration for the DEFINITY AUDIX System Release 4.0, 585-300-122 DEFINITY AUDIX System Release 4.0 — Maintenanc e, 585-300-121 AUDIX Ad ministration and Data Ac q uisition Pa c ka g e , 585-302-502 AMIS Analog Networking, 585-300-512 DEFINITY AUDIX System — Dig ital Networking , 585-300-534 Ord er training Acc ount ExecutiveDetermine whether the c ustomer wants to p urchase live or CD-ROM-based training , and ord er the ap prop riate c ourses. Table 2-1. New System with New Switch (Continued) Task Party RequirementsDate Complete Continued on next page
Planning for the DEFINITY AUDIX System Release 4.0 585-300-602 Issue 1 May 1999 New System Ordered with New Switch 2-5 2 Attend training Customer Attend any training c ourses you p urc hased . Prep are the site Customer Prep are the eq uip ment room for installation. See DEFINITY AUDIX System — System Description, 585-300-214 for comp lete information ab out environmental c onsid erations. To install the DEFINITY AUDIX system, each station must have a unique extension and c aller ID. The DEFINITY AUDIX system will rejec t the switch datab ase if two or more extensions have the same c aller ID or no caller ID b ecause this ap p ears to the DEFINITY AUDIX system as a d up licate ID. Mod ify the switc h datab ase at this time, if nec essary, to ensure that eac h station has a uniq ue caller ID. See Installation and Switc h Ad ministration for the DEFINITY AUDIX System Release 4.0, 585-300-122. Per f o r m software/station reviewsPro j ec t manag er and customerDetermine how the customer would like the switc h and the DEFINITY AUDIX system ad ministered d uring initial administration. ÜFill in the worksheets in Appendix B, Appendix C, and Appendix D. See Installation and Switc h Ad ministration for the DEFINITY AUDIX System Release 4.0, 585-300-122, and DEFINITY AUDIX System — Ad ministration , 585-300-507, for information ab out translations and ad ministration. Disc uss system sec urity issues, inc lud ing toll fraud. See B C S Pr o d uc t Se c ur i t y H a nd b oo k, 855-025-600, DEFINITY AUDIX System — System Desc rip tion , 555-300-214, DEFINITY AUDIX System — Feature Desc rip tions, 585-300-206 for more information about these issues. Table 2-1. New System with New Switch (Continued) Task Party RequirementsDate Complete Continued on next page
Planning for the DEFINITY AUDIX System Release 4.0 585-300-602 Issue 1 May 1999 New System Ordered with New Switch 2-6 2 Discuss the system password with the c ustomer. Customers c an c hang e the system p assword for the cust log in to whatever they want. Lucent Tec hnolog ies controls the p assword for the craft and other log ins, so the RSC c an p erform remote maintenanc e Allocate a Direc t Inward Dialing (DID) or Central Offic e (CO) Line for the AUDIX maintenanc e p ortPro j ec t manag er and customerThe c ustomer is resp onsib le for p rovid ing a remote-maintenanc e ac cess line to the modem of the DEFINITY AUDIX system. The c ustomer c an p urchase a 1FB from the local telep hone servic e provid er or provid e a DID line from the switc h. A c irc uit terminating at the switc h c onsole or other answering p osition is not suitable. Chec k the customer sitePro j ec t manag erVerify that the c ustomer’s eq uip ment room is ready for equipment delivery. Rec e iv e eq uip mentCustomer Rec eive the switch with the DEFINITY AUDIX system installed. Installing the System Install the DEFINITY AUDIX hard wareInstaller Install the c ab les, modems, terminals, and any other p erip heral equipment as describ ed in Installation and Switc h Administration for the DEFINITY AUDIX System Release 4.0, 585-300-122. Test the hard ware Installer Test the DEFINITY AUDIX hard ware. See Installation and Switc h Administration for the DEFINITY AUDIX System Release 4.0, 585-300-122, for d etailed instruc tions. Perform initial switc h ad ministrationSoftware sp ec ialist or design sp ec ialistUse the worksheets from App end ix B and the instructions in Installation and Switc h Ad ministration for the DEFINITY AUDIX System Release 4.0, 585-300-122, to perform the initial switch administration. Table 2-1. New System with New Switch (Continued) Task Party RequirementsDate Complete Continued on next page