Sending Functions
5-11
5
Original Orientation
To send the document in the orientation that can be read properly, specify the upper orientation of original. To 
use the functions below, select the orientation in which the original is set on the platen.
• 2-sided/Book Original
• Border Erase
* If [On] is selected as the  Orientation Confirmation (page 8-14)  setting in the System Menu, the selection 
screen for original orientation appears when you select any of the above functions.
When placing the...

Page 172

Sending Functions
5-12
4Select original orientation from [Top Edge Top] and 
[Top Edge Left].
5Press [OK].
6Specify the destination, and press the Start key to 
start sending.
File Format
Select the file format  of the image to send.
The table below lists the file  formats and their details.
NOTE: In the color mode, when auto color (color/black an d white) is selected, [JPEG] and [XPS] cannot be 
specified, and when black and whit e is selected, [JPEG], [High Comp. PD F], and [XPS] cannot be specified....

Page 173

Sending Functions
5-13
5
Use the procedure below to select the file format for transmission.
1Press the Send key.
2Place the originals on the platen.
3Press [Original/Sending Data Format] and then 
[File Format].
4Select the file format fr om [PDF], [TIFF], [JPEG], 
[XPS], and [High Comp. PDF].
When the color mode in scanning has been 
selected for Grayscale or  Full Color, set the image 
quality.
If you selected [PDF] or  [High Comp. PDF], press 
[Encryption] and specify the encryption settings.
5Press...

Page 174

Sending Functions
5-14
PDF Encryption Functions
If you have selected PDF or High Comp. PDF for file format, you can restrict the access level for displaying, 
printing, and editing PDFs by assigning a secure password.
The items you can restrict the access level with are as follows.
When you send a PDF file, use the procedure bel ow to encrypt the PDF file for transmission.
1Press the Send key.
2Place the originals on the platen.
3Press [Original/Sending  Data Format], [File 
Format], [PDF] or [High Comp....

Page 175

Sending Functions
5-15
5
11Restrict the access level of the PDF file. Press [ ] 
of  Printing Allowed  to select the item (the scope of 
limit). The item to be displayed differs according to 
the version of Acrobat selected in  Compatibility in 
step 4.
The table below shows the available settings.
12Press [ ] of  Changes Allowed , and select the 
item (the scope of limit).  The item to be displayed 
differs according to the version of Acrobat selected 
in  Compatibility  in step 4.
The table below shows...

Page 176

Sending Functions
5-16
The table below shows the available settings.
14Press [OK]  three times to return to Original/
Sending Data Format
.
15Specify the destination, and press the  Start key to 
start sending.
Image Quality
Select image quality suitable  to the type of original.
The table below shows the quality options.
Use the procedure below to select the quality when sending scanned originals.
1Press the  Send key.
2Place the originals on the platen.
3Press [Color/Image Quality] and then [Original...

Page 177

Sending Functions
5-17
5
Adjusting Density
Use the procedure below to adjust the density when scanning the originals.
The table below shows the available settings.
The procedure for adjusting the density is explained below.
1Press the Send key.
2Place the originals on the platen.
3Press [Color/Image Quality] and then [Density].
4When selecting manual density adjustment, press 
[-3] to [+3] ( Lighter - Darker ) to adjust density.
When selecting auto density adjustment, press 
[Auto].
5Press [OK].
6Specify...

Page 178

Sending Functions
5-18
Scan Resolution
Select the fineness of scanning resolution. The finer the scanning becomes (the larger the number becomes), 
the better the image quality becomes. However, better resolu tion also results in larger file size (file capacity) and 
longer scanning and sending times. The selectable  resolution is 200x100dpi Normal, 200x200dpi Fine, 
200x400dpi Super Fine, 300x300dpi, 400x400dpi Ultra Fine, or 600x600dpi.
The procedure for adjusting the scanning resolution when sending a...

Page 179

Sending Functions
5-19
5
Sharpness
Select the sharpness of the image outline.
The table below shows the available settings.
Use the procedure below to set the sharpness when sending scanned images.
1Press the Send key.
2Place the originals on the platen.
3Press [Color/Image Quality] and then [Sharpness].
4Press [-3] to [+3] ( Unsharpen - Sharpen ) to adjust 
the sharpness.
5Press [OK].
6Specify the destination, and press the  Start key to 
start sending.
Item
Detail
Sharpen Emphasize the image outline....

Page 180

Sending Functions
5-20
Background Density Adjustment
Lightens the background of the colored original when it is too dark.
NOTE: You cannot adjust the background density if you selected [Black & White] in Color / Grayscale / Black 
and White Selection (see page 5-21). 
Use the procedure below to set the background density when sending scanned images.
1Press the Send key.
2Place the originals on the platen.
3Press [Color/Image Quality] and then [Background 
Density Adj.].
4Press [On], and press [1] to [5]...