Page 71
INTER-TEL PRACTICES GLX INSTALLATION h MAINTENANCE TROUBLESHOOTING Issue 1, November 1985 FIGURE 52. INTERCOM TROUBLESHOOTING CHART (CONTD) SYMPTOM PROBABLE CAUSE Data noise System does not heard through have an isolated, speakerphone dedicated, AC or handset outlet Defective or loose cable connections Check for loose, open, or crossed wires, and correct. Station cable exposed to interference Ensure proper station cable runs. Refer to page 3-6. Defective keyset Replace keyset....
Page 72
INTER-TEL PRACTICES GLX INSTALLATION h MAINTENANCE TROUBLESHOOTING Issue 1, November 1985 FIGURE 5-3. C-0. LINE TROUBLESHOOTING CHART SYMPTOM PROBABLE CAUSE CORRECTIVE ACTION C.O. lines will C.O. ring dura- Attach a linemans test set not ring for tion timer is to one of the lines at the incoming calls set too long RJ connector. Place an out- going call that will ring in on the line with the test set. Check for ring signal. If you hear ring signal, set the timer to a shorter dura- tion....
Page 73
INTER-TEL PRACTICES TROUBLESHOOTING GLX INSTALLATION & MAINTENANCE Issue 1, November 1985 FIGURE 5-3. C.O. LINE TROUBLESHOOTING CHART (CONTD) SYMPTOM PROBABLE CAUSE CORRECTIVE ACTION Cannot place C.O. line uses an outside dial pulse signal call. C.O. dial tone is present and intercom works. Keyset is toll restricted (key- set option 6 enabled) The system is compatible with DTMF signal C.O. lines unless a DTMF-to-rotary converter is installed on each of the C.O. lines. Check the...
Page 74
INTER-TEL PRACTICES GLX INSTALLATION 6 MAINTENANCE TROUBLESHOOTING Issue 1, November 1985 FIGURE 5-3. C-0. LINE TROUBLESHOOTING CHART (CONTD) SYMPTOM PROBABLE CAUSE Outside call User error (line dropped upon key pressed answering or after initial during connection is conversation made) User error (digit key pressed after connection is made) Data base error Defective keyset Replace keyset. Defective Expan- sion PCB Replace Expansion PCB if the problem occurs on C.O. line 4, 5, or 6,...
Page 75
INTER-TEL PRACTICES GLX INSTALLATION h MAINTENANCE TROUBLESHOOTING Issue 1, November 1985 FIGURE 5-4. SYSTEM MALFUNCTIONS TROUBLESHOOTING CHART SYMPTOM All keysets in the system are inoperative. No LEDs light when a C.O. line key is pressed. PROBABLE CAUSE KSU AC power cord Plug cord into isolated, is not plugged in dedicated, AC outlet. Dedicated breaker has tripped AC fuse is open Station fuse(s) are open Defective Main Control PCB Defective power supply CORRECTIVE ACTION Reset...
Page 76
INTER-TEL PRACTICES GLX INSTALLATION & MAINTENANCE TROUBLESHOOTING Issue 1, November 1985 : -, FIGURE S-4. SYSTEM MALFUNCTIONS TROUBLESHOOTING CHART (CONTD) SYMPTOM PROBABLE CAUSE (2.0. line is Defective C.O. inoperative line from central throughout office the system CORRECTIVE ACTION Attach a linemans test set the line at the RJ connector and check for C.O. dial tone. If not present, contact the telephone company. . . ._ :; .:: C.O. lines mis- wired Check C.O. line connections...
Page 77
INTER-TEL PRACTICES TROUBLESHOOTING GLX INSTALLATION h MAINTENANCE Issue 1, November 1985 FIGURE 5-4. SYSTEM MALFUNCTIONS TROUBLESHOOTING CHART (CONTD) SYMPTOM PROBABLE CAUSE CORRECTIVE ACTION Radio frequency AC power cir- Refer to page 3-3. If cor- interference cuit is not rectly grounded, unplug AC (RFI) or elec- grounded power cord from.outlet and tromagnetic properly insert a ground isolation :. .: ::. interference plug into outlet. Plug AC : :. (EMI) present power cord into ground...
Page 78
INTER-TEL PRACTICES TROUBLESHOOTING GLX INSTALLATION h MAINTENANCE Issue 1, November 1985 4. CUSTOMER SfiPPORT DEPARTMENT 4.01 If problems persist, contact Inter-Tels Customer Support Department for assistance. They can be reached between 8:00 AM and 5:00 PM Mountain Standard Time (MST) at 602-961-9000 or l-800-523-8180. 4.02 For emergencies only: After office hours and on weekends, call 602-961-0277 and leave your message with the operator. A Customer Support Product Specialist will return...
Page 79
INTER-TEL PRACTICES GLX INSTALLATION h MAINTENANCE TROUBLESHOOTING Issue 1, November 1985 (8) w (10) Enter your distributor code (Inter-Tel account number as it appears on your monthly invoice) and press RETURN. Your terminal will print WELCOME TO ISIS, followed by a series of menus that will guide you to the information you need. When you are finished, select EXIT ISIS (option the main menu and terminate your call according instructions for you modem. G) from to the NOTE: If you have...
Page 80
INTER-TEL PRACTICES REPLACEMENT PARTS GLX INSTALLATION & MAINTENANCE Issue 1, November 1985 REPLACEMENT PARTS CONTENTS PAGE 1. INTRODUCTION ............................................. 6-l 2. ORDERING PROCEDURE ................... ../ ................. 6-l 3. REPLACEMENT PARTS LIST ................................... 6-l 4. RECOMMENDED SPARE PARTS .................................. 6-l 1. INTRODUCTION 1.01 This section provides the information necessary to order replacement parts...