INTER-TEL PRACTICES INSTALLATION GLX INSTALLATION % MAINTENANCE Issue 1, November 1985 For C.O. Lines -- if terminated on RJ14 jacks away from the MDF: For a better understanding of the supplies needed, refer to Fig- ure 3-4 on page 3-11. Two 4-conductor modular jack assemblies for every two C.O. lines installed. Two 2-pair mod-to-mod line cords for every two C.O. lines. 2-pair cable to extend from the RJ14 jack location to the MDF. For C.O. Lines -- if terminated on RJ14 jacks near the...
Page 32
INTER-TEL PRACTICES INSTALLATION GLX INSTALLATION c MAINTENANCE Issue 1, November 1985 4. STATION A. RUN THE 4.01 Using CABLING STATION CABLES the floor plan developed in pre-installation plan- ning, run 2-pair twisted cable from the MDF to each keyset loca- tion. Label both ends of every cable with the keyset intercom number (10-21). Follow these guidelines when running cable: l Avoid cable runs parallel to fluorescent light fixtures or AC lines not in conduit. If these obstacles are...
Page 33
INTER-TEL PRACTICES INSTALLATION GLX INSTALLATION h MAINTENANCE Issue 1, November 1985 FIGURE 3-2, TERMINATE STATION CABLES AT THE MDF See detailed chart of the individual wire terminations on the next page. AMPHENOL CONNECTOR i V/BR BR/V 211 v/s I s/v I I - L 66MI -5O- TYPE CONNECTING BLOCK Diagram of the station block above. 4 - CONDUCTOR MODULAR JACK ASSEMBLY & FEMALE AMPHENOL- TYPE CONNECTOR 66MI-60-TYPE CONN;CTtT;; ::YSET Page 3-7
Page 34
INTER-TEL PRACTICES INSTALLATION GLX INSTALLATION h MAINTENANCE Issue 1, November 1985 FIGURE 3-3. TERMINATE STATION CABLES AT THE MDF (CONT.) TERMINAL CABLE NUMBER PAIR FUNCTION 26 W-BL TIP 1 BL-W RING 27 w-o GND 2 o-w +28VDC 28 W-G TIP 3 G-W RING 29 W-BR GND 4 BR-W +28VlX 30 w-s TIP 5 s-w RING 31 R-BL GND 6 BL-R +28VDC 32 R-O TIP 7 O-R RING 33 R-G GND 8 G-R +28VDC 34 R-BR TIP 9 BR-R RING 35 R-S GND 10 S-R +28VDC 36 BK-BL TIP 11 BL-BK RING 37 BK-0 GND 12 0-BK +28VDC...
Page 35
INTER-TEL PRACTICES INSTALLATION GLX INSTALLATION & MAINTENANCE Issue 1, November 1985 C. TERMINATE S+ATION CABLES AT KEYSET LOCATIONS 4.03 Terminate the keyset end of each station cable on a 4-con- ductor modular jack assembly as shown in Figure 3-3 below. DO NOT mount them on the wall at this time. FIGURE 3-3. KEYSET MODULAR JACK ASSEMBLY WIRING BL/W D. PERFORM THE STATION LOOP RESISTANCE TEST NOTE: If performing the loop resistance test after the system is installed, unplug the keyset...
Page 36
INTER-TEL PRACTICES INSTALLATION GLX INSTALLATION h MAINTENANCE Issue 1, November 1985 5. CONNECT TIiE C-0. LINES 5.01 The installation procedure used to terminate C.O. lines at the MDF is dependent on the type of jack used by the telephone company and how close their jacks are to the MDF. The C.O. lines may be terminated on RJ14 (C or W) jacks or on an RJ21X block. Follow one of the three methods (A, B, or C) below. IMPORTANT NOTES: The first C.O. jack on the KSU connects lines 1 and 2, the...
Page 37
INTER-TEL PRACTICES INSTALLATION GLX INSTALLATION & MAINTENANCE Issue 1, November 1985 FIGURE 3-4. C.O. LINE TERMINATIONS FROM RJ14 JACKS RJl4 (C OR W) JACKS 7 r 4 - CONDUCTOR MOD. JACK ASSEMBLIES y TO C-0. ( hJ&o+ PER JACK) L-PAIR MOD-TO-MOD LINE CORDS 2-PAIR CABLES -KSU : _:: : ,‘X L P-PAIR MOD-TO-MOD LINE CORDS BL/W FIGURE 3-5. MODULAR JACK ASSEMBLY WIRING FOR C.O. LINES W/BL w/o o/w RING I RING2 Page 3-11
Page 38
INTER-TEL PRACTICES GLX INSTALLATION & MAINTENANCE INSTALLATION Issue 1, November 1985 B. C-0. LINES TERMINATED ON RJ14 JACKS NEAR THE MDF 5.02 Before using this procedure, read the IMPORTANT NOTES on page 3-10. Plug one end of a 2-pair line cord into each RJ14 jack. The other end of each line cord will be plugged into the corresponding C.O. jack on the KSU after it is installed. c. C.O. LINES TERMINATED ON AN RJ21X BLOCK I ,J ,> -. j .:; 5.03 Before using this procedure, read the IMPORTANT...
Page 39
INTER-TEL PRACTICES INSTALLATION GLX INSTALLATION b MAINTENANCE Issue 1, November 1985 : FIGURE 3-61 C-0. LINE TERMINATIONS FROM AN RJ2lX BLOCK TO RJ2lX C.O. BLOCK ._.. . AMPHENOL-TYI CONNECTOR CABLES 6. UNPACK AND INSPECT TEE KSU -KS” J _ 2 -PAIR MOD-TO-MOD LINE CORDS (1) Unpack the KSU and lay it on a flat surface with the cover facing up. Open it by removing the four retaining screws and lifting off the cover. **********t********************************************** * CAUTION...
Page 40
INTER-TEL PRACTICES INSTALLATION GLX INSTALLATION h MAINTENANCE Issue 1, November 1985 (3) If the KSU or any of its components are damaged, contact Inter-Tels Order Processing Department immediately. (4) You MUST activate the lithium battery by removing the red piece of paper located between it and the battery clip. Otherwise, the data base memory during a power outage. will not be protected (5) If you are installing the Expansion PCB, proceed to the next page. Otherwise, replace the KSU...