Inter-Tel Glx Installation And Field Maintenance Manual
Here you can view all the pages of manual Inter-Tel Glx Installation And Field Maintenance Manual. The Inter-Tel manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 61
INTER-TEL PRACTICES PROGRAMMING GLX INSTALLATION & MAINTENANCE Issue 1, November 1985 B. KEYSET FEATURES PROGRAMMING 5.03 For more information on these features, refer to the FEA- TURES section. Program entries as described below. Refer to page 4-5 for general programming information, if needed. (1) Place the PRG EN switch in the ON position. (2) From the desired keyset, program the keyset features as follows. a. C.O. line restriction: Designates the C.O. line(s) that cannot be used to make...
Page 62
INTER-TEL PRACTICES PROGRAMMING GLX INSTALLATION 6, MAINTENANCE Issue 1, November 1985 c. Keyset options: No options are preset during ini- tialization. 1. While on hook, dial #3. 2. Dial the desired option(s). For example, dial- ing #3123 will enable options 1, 2, and 3. (To return to default status, skip this step.) Option 1 - Incoming page disable: Internal pages will not be heard through this keysets speaker. Option 2 - Ring intercom...
Page 63
INTER-TEL PRACTICES TROUBLESHOOTING GLX INSTALLATION & MAINTENANCE Issue 1, November 1985 TROUBLESHOOTING CONTENTS PAGE 1. INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-l 2. DEFECTIVE UNIT RETURN POLICY . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-l 3. TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-2 A. PRE-TROUBLESHOOTING CHECKLIST....................... 5-2 B....
Page 64
INTER-TEL PRACTICES TROUBLESHOOTING GLX INSTALLATION & MAINTENANCE Issue 1, November 1985 3. TROUBLESHOOTING A. PRE-TROUBLESHOOTING CHECKLIST 3.01 Use this troubleshooting checklist before you start the system troubleshooting procedures. It may save you time and possibly eliminate the need for detailed troubleshooting. NOTE: In locations where there is low humidity, static can build up= This often causes small shocks or sparks when metal objects are touched. Although the internal metal...
Page 65
INTER-TEL PRACTICES TROUBLESHOOTING GLX INSTALLATION h MAINTENANCE Issue 1, November 1985 NOTE: *If the LED is not flashing, there may still be an error. Place the PWR switch in the OFF position for 10 seconds; then return it to the ON position. the PWR switch off drops all calls in progress.) (Turning If the LED flashes, a software error has occurred. Follow the procedures given below. a. If the ERROR LED is flashing, an error has occurred in the system. Count the number of flashes...
Page 66
INTER-TEL PRACTICES TROUBLESHOOTING GLX INSTALLATION & MAINTENANCE Issue 1, November 1985 B. SYSTEM TROUBLESHOOTING 3.02 The troubleshooting failures have been divided PROCEDURES procedures for correcting equipment into four categories: l Feature Failure l Intercom Call-Related Problems o Outside Call-Related Problems l System Malfunctions ; : : ,: 3.03 The troubleshooting charts list symptoms, possible causes, and corrective actions. Look for the problem reported and per- form the...
Page 67
INTER-TEL PRACTICES TROUBLESHOOTING GLX INSTALLATION h MAINTENANCE Issue 1, November 1985 FIGURE 5-1. FEATURE FAILURE TROUBLESHOOTING CHART SYMPTOM PROBABLE CAUSE CORRECTIVE ACTION Cannot place a User error Refer to page 7-24. call on hold Defective keyset Replace keyset. Defective Expan- Replace Expansion PCB. sion PCB* Defective Main Replace KSU or contact Inter- Control PCB Tel Customer Support for assistance. Last number User error Refer to page 7-23. redial does not work...
Page 68
INTER-TEL PRACTICES GLX INSTALLATION & MAINTENANCE TROUBLESHOOTING Issue 1, November 1985 FIGURE 5-l; FEATURE FAILURE TROUBLESHOOTING CHART (CONTD) SYMPTOM PROBABLE CAUSE CORRECTIVE ACTION Headset enable, PRG EN switch is PRG EN switch must be in the do-not-disturb, in the ON posi- OFF position for these fea- background tion tures to be used. music and call forward codes do not work Cannot initiate User error a conference Conference cir- cuits are busy Intercom channels are busy...
Page 69
INTER-TEL PRACTICES GLX INSTALLATION & MAINTENANCE TROUBLESHOOTING Issue 1, November 1985 FIGURE 5-1. FEATURE FAILURE TROUBLESHOOTING CHART (CONTD) SYMPTOM PROBABLE CAUSE Speakerphone User error not operating properly Automatic speakerphone is disabled Headset is enabled Defective keyset Replace keyset. Defective Expan- sion PCB Replace Expansion PCB. If if problem occurs at keyset 18, 19, 20, or 21. Defective Main Control PCB CORRECTIVE ACTION Refer to page 7-12 and 7-19....
Page 70
INTER-TEL PRACTICES TROUBLESHOOTING GLX INSTALLATION h MAINTENANCE Issue 1, November 1985 i .. FIGURE 5-2. INTERCOM TROUBLESHOOTING CHART NOTE: These symptoms are isolated to one keyset only. For iden- tical problems involving more than one keyset, refer to Figure 5-4, System Malfunctions Troubleshooting Chart, on page 5-13. SYHPTOM No intercom dial tone PROBABLE CAUSE CORRECTIVE ACTION :.. : i -.._:, Defective station Check cable connections. 1 :.-: cabling Defective keyset Replace...