INTER-TEL PRACTICES SPECIFICATIONS GLX INSTALLATION & MAINTENANCE Issue 1, November 1985 FIGURE 2-3. EXPANSION PCB , :. .,:_ ,;._; ;. I...‘. . . . I’?.‘. _/, /. Page 2-8
Page 22
INTER-TEL PRACTICES SPECIFICATIONS GLX INSTALLATION & MAINTENANCE Issue 1, November 1985 4. KEYSETS ’ 4.01 Two models of keysets are available for use on the system: the Executive Keyset and the Standard Keyset. Photographs of the keysets appear on pages 2-10 and 2-11. 4.02 Features on both keysets: l 12-key pushbutton keypad l 6 C.O. line keys l Integrated (built-in) speakerphone l Hearing aid-compatible (HAC) handset l Voice volume and ring volume controls l Reversible baseplate for wall...
Page 23
INTER-TEL PRACTICES SPECIFICATIONS GLX INSTALLATION & MAINTENANCE Issue 1, November 1985 FIGURE 2-4. GLX EXECUTIVE KEYSET a I 6 C.O. LINES 12 FEATURE KEYS RING VOLUME CONTROL 12 -KEY PUSHBUTTON a 7 VOICE VOLUME CONTROL DIRECT STATION SELECTION/ BUSY LAMP FIELD KEYS Page 2-10
Page 24
INTER-TEL PRACTICES SPECIFICATIONS GLX INSTALLATION & MAINTENANCE Issue 1, November 1985 FIGURE 2-5. GLX STANDARD KEYSET A I A 2 / 3 D 4 6 C.O. LINES SPEAKER 12- KEY PUSH BUTTON KEYPAD HEARING AID - COMPATiBLE HANDSET 6 FEATURE KEYS RING VOLUME CONTROL A 7 VOICE VOLUME CONTROL Page 2-11
Page 25
INTER-TEL PRACTICES GLX INSTALLATION & MAINTENANCE SPECIFICATIONS Issue 1, November 1985 5. OPTIONAL EQUIPMENT 5.01 Optional equipment for keysets: 0 Headset: A headset can be attached by-unplugging the hand- set from the base, plugging the headset into the handset jack, and entering a- feature code at the keyset to enable the device. Calls are processed using the ON/OFF key. The GLX keysets are compatible with industry-standard, 4-con- ductor, modular headsets that have dynamic microphones...
Page 26
INTER-TEL PRACTICES SPECIFICATIONS GLX INSTALLATION & MAINTENANCE Issue 1, November 1985 5.03 Battery back-up: To prevent loss of service in the event of a power failure or a brownout condition, there are three possible sources for battery back-up. Inter-Tel recommends the use of the tollowing customer-provided equipment. Refer to page 3-22 for installation instructions. l A 30V battery pack can be connected to the KSU, using the input labeled BATT 30V. The input requires a Molex 3-con-...
Page 27
INTER-TEL PRACTICES INSTALLATION GLX INSTALLATION h MAINTENANCE Issue 1, November 1985 INSTALLATION CONTENTS PAGE 1. 2. 3. 4. 5. 6. 7; 8. ‘9. INTRODUCTION ............................................ 3-2 PRE-INSTALLATION PLANNING ............................... 3-2 A. SITE PLANNING CHECKLIST ............................. 3-3 B. TOOLS AND SUPPLIES CHECKLIST ........................ 3-4 MOUNT THE MAIN DISTRIBUTION FRAME (MDF) ................. 3-5 STATION CABLING...
Page 28
INTER-TEL PRACTICES INSTALLATION GLX INSTALLATION h MAINTENANCE Issue 1, November 1985 1. INTRODUCTION 1.01 This section describes the recommended stalling the system hardware. For hardware to the SPECIEICATIONS section of the manual. 2. PRE-INSTALLATION PLANNING procedures for in- descriptions, refer 2.01 Before installing the system, plan the location for the equipment, develop a floor plan to show all keyset locations, and collect the necessary tools and supplies, 3-3 to 3-5. as...
Page 29
INTER-TEL PRACTICES INSTALLATION GLX INSTALLATION & MAINTENANCE Issue 1, November 1985 A. SITE PLANNIhG CHECKLIST Select the KSU location to minimize station cable run lengths. DO NOT exceed measurements of 40 ohms or 800 feet (243 meters), using 24AWG wire. The ohm value is the loop measurement; the foot (meter) length is the maximum one-way measurement from the KSU. Prepare a floor plan for the keyset locations, using a star (home-run) configuration. Include each keysets intercom number...
Page 30
INTER-TEL PRACTICES INSTALLATION GLX INSTALLATION b MAINTENANCE Issue 1, November 1985 Ample air space should be provided for the KSU since the power supply is convection cooled. DO NOT block the cool- ing vents located on the top and bottom of the KSU. Never place anything on top of the KSU. If keysets are wall mounted, the wall should be able to support twice the weight of the keyset. A keyset weighs 2.5 pounds (1.13 kilograms). B. TOOLS AND SUPPLIES CHECKLIST A high-impedance, digital...