Home > Honeywell > Control panel > Honeywell Galaxy 3 User Manual

Honeywell Galaxy 3 User Manual

Here you can view all the pages of manual Honeywell Galaxy 3 User Manual. The Honeywell manuals for Control panel are available online for free. You can easily download all the documents as PDF.

Page 51

Galaxy 3 Series Programming Manual
45
1.  Service
This option enables type 3.6 users to control the access mode of the remote servicing package.  There are
several options available for increased flexibility and security.
0 = INT Telecoms
This option selects the on-board telecoms as the communication device.
0 = Direct Access
On selecting this option, a 40 minute access period is enabled on the Galaxy panel; remote servicing software
can directly access the system during this period. Once access to the...

Page 52

Galaxy 3 Series Programming Manual
46
3 = EXT Telecoms
0 = Direct Access
See INT Telecoms description
1 – 5 = Call Back 1 – 5 (see Telecoms description)
2.  Send Alarms
Option not available
3.  Call Galaxy
Option not available
4.  Auto Service
 The Galaxy 3 Series panels can be programmed to automatically initiate communications to remote servicing
software, under three circumstances:
• If any site programming has changed the panel will automatically send the new programming to the
downloader.
• On a...

Page 53

Galaxy 3 Series Programming Manual
47
47 - Remote Access (contd)
3 = Confirm
In this mode, when engineering mode is exited following a change to the panel programming, a message is
displayed at the keypad to asking whether a remote connection should be initiated. This must be authorized by
an appropriate user type before the call is made.
Once authorized, a two minute delay period is initiated. During this period, the engineer can initiate or cancel
the call.
If connection is initiated the panel uploads...

Page 54

Galaxy 3 Series Programming Manual
48
4 = Conn. Retry
If the attempt to initiate a remote servicing call fails, the panel can be programmed do repeat dial attempts.
There are three further options:
1 = Retry Interval
The dial attempts can be programmed to occur from 0-60 minutes. Setting the value to 0 disables the feature
The default setting is 30 minutes.
2 = Retry Duration
The length of time that the panel tries to do a remote servicing call can be programmed from 0-24 hours.
setting the value to 0...

Page 55

Galaxy 3 Series Programming Manual
49
47 - Remote Access (contd)
1 = Schedule
This option controls the schedule for the initiation of communication for remote routine inspection. The sched-
ule can be set from 0-365 days. The default is 0 days which disables the function.
2 = Advice
This option controls the method by which communication is initiated. It can be initiated automatically by the
schedule programmed above or manually by user entry of the Service PIN code, with or without a notification...

Page 56

Galaxy 3 Series Programming Manual
50
Option 48 – Access Authorization
This option allows access to be authorized for engineers for system programming and for managers in order to
add/delete/change all user codes.
1 = Engineer
The engineer code is assigned programmed as dual by default. This prevents the engineer from accessing
engineer mode unless authorized to do so by a valid code. To gain access to the engineer menu a type 3.6
user must enter their code, and enable the Engineer Access option. This...

Page 57

Galaxy 3 Series Programming Manual
51
Section 8:  Engineer 1
Option 51 – Parameters
This option allows the engineer to modify the system functions. Options can be selected using the A or B keys
or by entering the two digit parameter number and pressing the ent key.  The selected options can then be
programmed by using the A key to increase or the B key to decrease the values assigned to the parameter;
pressing the ent key accepts the new value and returns to the previous menu level. Any parameters that...

Page 58

Galaxy 3 Series Programming Manual
52
51 - Parameters (cont’d)
Table 9. System Parameters
Parameter Groups Galaxy 48 Galaxy 144 Galaxy 520
53RF Stop Mode not available99 9
54Keypad Access not available99 9
55Confirm not available99 9
56Force Restore not available99 9
57Bell Extend not available99 9
58Power Alarm not available99 9
59Part Tone not available99 9
60RF Parameters not available99 9
61Activity Mon not available99 9
62Lockout not available99 9
63Banner alerts not available99 9
64Set Override not...

Page 59

Galaxy 3 Series Programming Manual
53
01 = Bell Time
The duration of the Bells output activation is programmable within the range 0–30 minutes; the default is 15.
Assigning a value of 00 minutes sets the Bell Time to infinity.
This parameter can be assigned a different value for each group.
The Entry/Exit Horn is subject to the Bell Time parameter in both the set and unset conditions.
02 = Bell Delay
The delayed activation of the bell is programmable within the range 0–20 minutes; the default is 0. The...

Page 60

Galaxy 3 Series Programming Manual
54
Modified Abort Operation
Hash # abort alters the standard operation so that the signalling of the intruder condition is delayed until the
end of the abort time. If the system is unset during the entry time or abort time, no alarm conditions will be
signalled.
Star º abort alters the standard operation so that if a user strays from the entry route within the entry time,
the intruder is signalled as soon as the entry deviation occurs.
NOTE 1:To comply with DD243:2002,...
Start reading Honeywell Galaxy 3 User Manual

Related Manuals for Honeywell Galaxy 3 User Manual

All Honeywell manuals