Page 81
Galaxy 3 Series Programming Manual 75 Table 17. Available Zone Functions 52 - Program Zones (cont’d) Zone Function 01 Final 02 Exit 03 Intruder 04 24 Hours 05 Security 06 Dual 07 Entry 08 Push Set 09 Keyswitch 10 Secure Final 11 P a rt F i na l 12 Part Entry 13 PA 14 PA Silent 15 PA Delay 16 PA Delay Silent 17 Link 18 Spare 19 Fire 20 Tamper 21 Bell Tamper 22 Beam Pair 23 Battery Low 24 Line Fail 25 AC Fail 26 LogZone Function 27 Remote Access 28 Video 29 Video Exit 30 Intruder Delay 31 Log...
Page 82
Galaxy 3 Series Programming Manual 76 01 Final Zones programmed as Final initiate the unsetting procedure and terminate setting procedure; opening the Final zone when the system or group is set starts the entry timer; opening and then closing the Final zone during the exit procedure sets the system or assigned groups, providing all the zones are closed. The opening (+) and closing (–) of Final zones during the setting and unsetting procedures are recorded in the event log. Pressing the 7 key when...
Page 83
Galaxy 3 Series Programming Manual 77 06 Dual (Double Knock) The operation of the Dual (Double Knock) function is identical to the Intruder function, with the exception that an alarm condition is activated only when there have been two activations from any Dual zones (assigned to the same group) within a 20 minute period while the system is set. 07 Entry This function initiates the unsetting procedure in the same way as a Final zone. However, during the setting routine an Entry zone operates as an Exit...
Page 84
Galaxy 3 Series Programming Manual 78 If the system is set, operating a Keyswitch immediately unsets the assigned groups; there is no entry time countdown. The Part attribute of the Keyswitch function defaults to 0 (disabled); the standard Keyswitch function full sets the system. To part set the system using the Keyswitch, the Part attribute must be enabled. NOTE:The operation of a Keyswitch zone can be extended to the setting and unsetting of multiple groups by pressing the 7 key when assigning a group...
Page 85
Galaxy 3 Series Programming Manual 79 13 PA The PA (Personal Attack) function is continuously operational. Activation of this zone type overrides the Bell Delay parameter and causes an instant full alarm condition that requires to be reset with a code authorized for PA Reset — refer to Option 51 – PARAMETERS, 22 = PA Reset; the Intruder outputs are not acti- vated by PA zones. NOTE:If a PA zone is open, it is indicated on the keypad whenever a valid code is entered. The group that the open PA is assigned...
Page 86
Galaxy 3 Series Programming Manual 80 17 Link This zone type has no operational function; it is designed to be used as a source of a link - refer to option 54 = LINKS. The activation (+) and de-activation (–) of Link zones is recorded in the event log. 18 Spare The Spare function allows any zones that are not being used to be ignored by the system; the resistance readings from the circuit - including the tamper conditions - do not activate an alarm condition. NOTE:It is recommended that all unused zones...
Page 87
Galaxy 3 Series Programming Manual 81 24 Line Fail The Line Fail function is used to monitor the communication line that a remote signalling device is connected to for communications failure. When the system is in the unset state, the first activation of a Line Fail zone causes a local alarm and the message COMMS FAILURE is displayed, subsequent Line Fail activations do not sound the local alarm; the only indication is the keypad display. When the system is set, activation of the Line Fail zone overrides...
Page 88
Galaxy 3 Series Programming Manual 82 30 Intruder Delay The Intruder Delay function is identical to the Intruder function, with the exception that the full alarm activa- tion can be delayed for up to 50 minutes (0–3000 seconds); this is determined by the Delay Alarm param- eter (option 51.31). The Intruder Delay zone must remain open for the period of the Delay Alarm param- eter; while the zone is open the Entry/Exit Horns activate to remind the user that the Delay Alarm is count- ing down. Unsetting the...
Page 89
Galaxy 3 Series Programming Manual 83 35 = Exit Guard The Exitguard function allows a zone to be used to omit other zones on the system. This is useful for permit- ting access via doors programmed as 24 Hours or Security. The Exitguard zone must be the source of a link (refer to option 54 = LINKS); the destination of the Exitguard link is either a zone address or an output type. When opened, the Exitguard omits the zone entered as the link destination; an alarm is not activated if the Exitguard zone is...
Page 90
Galaxy 3 Series Programming Manual 84 38 PA Unset This PA Unset function is identical to the PA Silent function, with the exception that it is only operational when the system is unset; the function is inactive when the group is set. 39 Keyswitch Reset The Keyswitch Reset function allows alarms to be cancelled and the system to rearm without unsetting the Galaxy. The type of reset authorization is determined by the Keyswitch Level (option 51.14). The type required to reset Intruder, PA and Tamper alarms...