35
5 = Temporary Codes
Temporary Codes allows a PIN to be temporarily allocated to a user. On selecting this option, enter the
number of days (0 – 99) that the code is to remain active. The default setting of 0 indicates that the code is
permanent. A temporary code expires and is removed from the codes list at midnight after the assigned
number of days. A code that has been assigned as a Temporary Code is indicated on the user code display
by a ^ between the user number...

Page 42

Galaxy 3 Series Programming Manual
36
On selecting the Modify Groups option, the groups currently allocated to the user are displayed. All user
default to group 1. Pressing the group number toggles the group assigned to the user; pressing 2 and 3 assign
groups 2 and 3 to the user; pressing 1 (when group 1 is already assigned) removes group 1 from the user
code. To assign group choice to the user, press the 7 key. When the required groups have been assigned to
the user, press the ent key to accept the...

Page 43

Galaxy 3 Series Programming Manual
37
By default MAX Number is empty.
To enter the required number:
1.Enter the unique 10 digit number laser etched onto the MAX/MicroMAX card/Fob tag or
enter the unique RF keyfob button identifier generated by the RF RIO (refer to RF RIO programming
instructions II1-0076 for details) or
press the A and 1 keys simultaneously of the KeyProx and present the card/fob to the KeyProx reader
within five seconds. The decrypted number in the card will be self learned onto the...

Page 44

Galaxy 3 Series Programming Manual
38
42 - Codes (cont’d)
If a user’s card number is assigned a *, then the card becomes Dual access. This means that it will not open
the door on its own; it needs another PIN or card as well. If the PIN belonging to the same user has a #
assigned, then that PIN must be entered first before access will be granted to that card.
If the PIN has no # assigned, then the card will work only in conjunction with any other Dual Access card that
shares one or more groups (see...

Page 45

Galaxy 3 Series Programming Manual
39
Option 43 – Summer (Quick Menu Option 9)
The Daylight Savings Time is in accordance with European standards. The Daylight Savings time is described
as follows:
On the first day of each year, the British Summer Time (BST) Start date is set to the last Sunday in March
and the End date is set to the last Sunday in October.
 The operation of the Summer option is as follows: at 01:00 hours (GMT) on the Start date, the system clock
advances to 02:00 hours (DST); at 02:00...

Page 46

Galaxy 3 Series Programming Manual
40
45 - Timer Control
Option 45 – Timer Control
1 = View
This option allows the programmed times in each of the Timers to be viewed:
1.Timer A;
2.Timer B;
3.Autoset
Use the A and B keys to scroll through each of the programmed times.
NOTE:The programmed times cannot be modified using this option.
All of the programmed timers - Timer A, Timer B, Autoset - can be printed out using option 57.11 =
SYSTEM PRINT.Timers.
2 = Holidays
This function allows up to ten holiday...

Page 47

Galaxy 3 Series Programming Manual
41
2 = Assign Groups
This function determines which of the groups are affected by the programmed holiday periods.
On selecting the Assign Groups option, the groups currently assigned to the programmed holiday periods are
indicated by a Y below the group; an N is displayed below the unassigned groups. All groups default to Y.
Pressing the group number toggles the group status. When the required groups have been assigned to the
holidays, press the ent key to accept the...

Page 48

Galaxy 3 Series Programming Manual
42
On selecting the option, the early opening status of the groups is displayed; early opening enabled is indicated
by a Y below the group; an N is displayed below the groups that are not programmed to open early. All
groups default to N.
NOTE:Only the engineer can enable early opening for individual groups, but global enable must be done
first.
5 = Late Work
The Late Work option — if programmed as 1 = ON — authorizes an Autoset Extension in advance of the
prewarning...

Page 49

Galaxy 3 Series Programming Manual
43
46 - Group Omit
2 = Pattern Day
The Pattern Day can only be allocated by the engineer. This option determines the programmed timers that
are effective when the Weekend Day option is selected by the user; the timers of the selected Pattern Day
are adopted by the days selected for weekend work.
On selecting this option the programmed Pattern Day is displayed; the default is 1 = MON.  Use the A or B
keys to select the required day or days and press the ent key to accept...

Page 50

Galaxy 3 Series Programming Manual
44
47 - Remote Access
Option 47 – Remote Access
This menu option permits control of all site initiated remote connectors. The menu structure for this option is
shown below.
Figure 4. Remote Access Structure
47 = Remote Access
1= Service0 = Int Telecoms0 = Direct Access
1 = Call back-1 to 5 = Call back-5
1 = ISDN
0 = Direct Access
1 = Call back-1 to 5 = Call back-5
2 = Ethernet
0 = Direct Access
1 = Call back-1 to 5 = Call back-5
3 = Ext Telecoms0 = Direct Access
1 =...