Galaxy 3 Series Programming Manual
5
Accessing Engineer Mode
User Authorized Access
Entry to the engineer mode is authorized by a user with access to menu option 48.1  = ACCESS AUTH.
Engineer.  The user selects this option and presses key 1 to enable engineer access. The engineer code must
then be entered within five minutes of the option being enabled. A single entry of the engineer code directly
accesses the mode, without activating an engineer tamper alarm. If the code is not entered within the five...

Page 12

Galaxy 3 Series Programming Manual
6
 User Access
Aborting the Exit Engineer Mode Procedure
If the esc key is pressed at any point while engineer mode is being exited, before the normal banner is dis-
played, the exit procedure is aborted and the system remains in engineering mode.
Multi User Access
The Galaxy allows multi-user access. A maximum of 4 users (3-48), 8 users (3-144) and 16 users (3-520)
can simultaneously carry out tasks on the system. 

Page 13

Galaxy 3 Series Programming Manual
7
 Setting the System
R = Ready
F  = Fault (group is unset and at least 1
zone is open)
P = Part Set
S (flashing)  = selected for setting
S (steady)  = already set
L = Group is locked out and cannot be unset.
-  = Group is not available to the user
Section 3:  Setting Options
Setting the System Using a PIN
Full Setting
Enter:USER CODE + A
If groups are enabled and the user code has been assigned group choice then the keypad displays the set
status of the available...

Page 14

Galaxy 3 Series Programming Manual
8
Unsetting the System Using a PIN
During the unsetting procedure, initiated by the opening of FINAL or ENTRY zone on a set group, the
system is unset by entering the user code followed by the A key.
• If the user does not have group choice, all of the groups assigned to the code are instantly unset.
• If the user has group choice only the group that the FINAL or ENTRY zone is assigned to is
unset; all of the other groups remain set. The system displays the set status...

Page 15

Galaxy 3 Series Programming Manual
9
 Card Setting
If the card user has group choice all groups available to the user will be displayed on the keypad. The user
must select the groups to be set/unset/part set using the appropriate number keys, as per normal PIN users.
If the card user has no group choice then the card held setting function will commence automatically.
Unsetting the System with Proximity Cards
The system or groups can be unset using proximity cards with the MAX or KeyProx modules.
If the...

Page 16

Galaxy 3 Series Programming Manual
10
 Setting Features
Resetting Using Alarm Cause Code
If enabled in menu option 51.72, when a reset is required, an alarm cause code must be entered to reset the
system.
If there are multiple alarm causes and/or multiple groups require to be reset, then the alarm cause code only
has to be entered once. The user enters the most appropriate code as determined on site. The cause code
values should be determined in conjunction with the Alarm Receiving Centre (ARC)....

Page 17

Galaxy 3 Series Programming Manual
11
 Setting Features (cont’d)
Pressing the 7 and # keys again toggles the display to show the status of the groups individually. To move
between each groups, press the 7 and A or the 7 and B keys simultaneously.
Pressing the 7 and # keys again returns the keypad to the banner display.
08:58 TUE 22 NOV 08:58 TUE 22 NOV08:58 TUE 22 NOV 08:58 TUE 22 NOV
08:58 TUE 22 NOV
A1U Group A1 A1U Group A1A1U Group A1 A1U Group A1
A1U Group A1
Group A1 is unset
Galaxy 3-520
The...

Page 18

Galaxy 3 Series Programming Manual
12
 Setting Features (cont’d)
If the programmed Setting Logic results in none of the selected groups being allowed to set, a warning
message is displayed on the keypad. This message does not appear if at least one group sets.
2 Groups not set 2 Groups not set2 Groups not set 2 Groups not set
2 Groups not set
[]  to view []  to view[]  to view []  to view
[]  to view
Entry Time
The system begins the unsetting routine whenever a Final or Entry zone activates. The...

Page 19

Galaxy 3 Series Programming Manual
13
Section 4:  Menu Options 11-19
Option 11 – Omit Zones  (Quick Menu Option 0)
Code + ent + 11 + ent + A or B to select zone + # +
A or B to select zone + # + ..........
ent (to set) or esc (to select another option)
This option allows zones to be temporarily removed (omitted) from the system. Once a zone has been omitted
it does not generate an alarm condition (including tamper). The omitted zones are reinstated automatically
when the system is unset or manually when...

Page 20

Galaxy 3 Series Programming Manual
14
There are five zone types which vary from the standard Omit Zones operation:
•Vibration Zones — if the omitted zone is a Vibration zone, then all zones (in all groups) programmed as
this type are block omitted. The Vibration zones remain omitted until they are manually reinstated.
Unsetting the system does not reinstate Vibration zones.
•ATM1/2/3/4 Zones — a single AT M zone type can be omitted for the duration of the period entered in
the ATM Timeout parameter...