Honeywell Galaxy 3 User Manual
Here you can view all the pages of manual Honeywell Galaxy 3 User Manual. The Honeywell manuals for Control panel are available online for free. You can easily download all the documents as PDF.
Page 11
Galaxy 3 Series Programming Manual 5 Accessing Engineer Mode User Authorized Access Entry to the engineer mode is authorized by a user with access to menu option 48.1 = ACCESS AUTH. Engineer. The user selects this option and presses key 1 to enable engineer access. The engineer code must then be entered within five minutes of the option being enabled. A single entry of the engineer code directly accesses the mode, without activating an engineer tamper alarm. If the code is not entered within the five...
Page 12
Galaxy 3 Series Programming Manual 6 User Access Aborting the Exit Engineer Mode Procedure If the esc key is pressed at any point while engineer mode is being exited, before the normal banner is dis- played, the exit procedure is aborted and the system remains in engineering mode. Multi User Access The Galaxy allows multi-user access. A maximum of 4 users (3-48), 8 users (3-144) and 16 users (3-520) can simultaneously carry out tasks on the system.
Page 13
Galaxy 3 Series Programming Manual 7 Setting the System R = Ready F = Fault (group is unset and at least 1 zone is open) P = Part Set S (flashing) = selected for setting S (steady) = already set L = Group is locked out and cannot be unset. - = Group is not available to the user Section 3: Setting Options Setting the System Using a PIN Full Setting Enter:USER CODE + A If groups are enabled and the user code has been assigned group choice then the keypad displays the set status of the available...
Page 14
Galaxy 3 Series Programming Manual 8 Unsetting the System Using a PIN During the unsetting procedure, initiated by the opening of FINAL or ENTRY zone on a set group, the system is unset by entering the user code followed by the A key. • If the user does not have group choice, all of the groups assigned to the code are instantly unset. • If the user has group choice only the group that the FINAL or ENTRY zone is assigned to is unset; all of the other groups remain set. The system displays the set status...
Page 15
Galaxy 3 Series Programming Manual 9 Card Setting If the card user has group choice all groups available to the user will be displayed on the keypad. The user must select the groups to be set/unset/part set using the appropriate number keys, as per normal PIN users. If the card user has no group choice then the card held setting function will commence automatically. Unsetting the System with Proximity Cards The system or groups can be unset using proximity cards with the MAX or KeyProx modules. If the...
Page 16
Galaxy 3 Series Programming Manual 10 Setting Features Resetting Using Alarm Cause Code If enabled in menu option 51.72, when a reset is required, an alarm cause code must be entered to reset the system. If there are multiple alarm causes and/or multiple groups require to be reset, then the alarm cause code only has to be entered once. The user enters the most appropriate code as determined on site. The cause code values should be determined in conjunction with the Alarm Receiving Centre (ARC)....
Page 17
Galaxy 3 Series Programming Manual 11 Setting Features (cont’d) Pressing the 7 and # keys again toggles the display to show the status of the groups individually. To move between each groups, press the 7 and A or the 7 and B keys simultaneously. Pressing the 7 and # keys again returns the keypad to the banner display. 08:58 TUE 22 NOV 08:58 TUE 22 NOV08:58 TUE 22 NOV 08:58 TUE 22 NOV 08:58 TUE 22 NOV A1U Group A1 A1U Group A1A1U Group A1 A1U Group A1 A1U Group A1 Group A1 is unset Galaxy 3-520 The...
Page 18
Galaxy 3 Series Programming Manual 12 Setting Features (cont’d) If the programmed Setting Logic results in none of the selected groups being allowed to set, a warning message is displayed on the keypad. This message does not appear if at least one group sets. 2 Groups not set 2 Groups not set2 Groups not set 2 Groups not set 2 Groups not set [] to view [] to view[] to view [] to view [] to view Entry Time The system begins the unsetting routine whenever a Final or Entry zone activates. The...
Page 19
Galaxy 3 Series Programming Manual 13 Section 4: Menu Options 11-19 Option 11 – Omit Zones (Quick Menu Option 0) Code + ent + 11 + ent + A or B to select zone + # + A or B to select zone + # + .......... ent (to set) or esc (to select another option) This option allows zones to be temporarily removed (omitted) from the system. Once a zone has been omitted it does not generate an alarm condition (including tamper). The omitted zones are reinstated automatically when the system is unset or manually when...
Page 20
Galaxy 3 Series Programming Manual 14 There are five zone types which vary from the standard Omit Zones operation: •Vibration Zones — if the omitted zone is a Vibration zone, then all zones (in all groups) programmed as this type are block omitted. The Vibration zones remain omitted until they are manually reinstated. Unsetting the system does not reinstate Vibration zones. •ATM1/2/3/4 Zones — a single AT M zone type can be omitted for the duration of the period entered in the ATM Timeout parameter...