Page 101

Galaxy 3 Series Programming Manual
95
09 Set (Reflex)
The Set output is activated when the assigned groups on the system are set. This output is a Reflex output
and follows the set and unset status of the groups.
10 Engineer (Reflex)
The Engineer output is activated while the engineer mode is being accessed.
11 Spare (Latch)
The Spare output has function: it is used to designate outputs that are not being used on the system.
12 Ready (Reflex)
The Ready output is active when all zones in the system...

Page 102

Galaxy 3 Series Programming Manual
96
18 E/E Horn (Latch)
The Entry/Exit Horn output has a dual function:
• in an alarm condition its function is identical to that of the Horn output;
• during the unsetting and setting of the system it is used to provide an indication on the
status of the system.  The indication states are as follows:
• General Alarm - ON 500 msecs. OFF 500 msecs.
• Clear to Exit -Continuous
• Exit interrupted - ON 100 msecs. OFF 100 msecs.
• 75% Exit Time - ON 200 msecs. OFF 200 msecs....

Page 103

Galaxy 3 Series Programming Manual
97
24 Batt Test
This output is activated when a battery load test is in progress. Refer to option
61.1.4 = Diagnostics.Latest.PSU Comms.
25 Wrong CD
This output is activated whenever a wrong code alarm occurs. That is, when six wrong codes in succession
are entered at the keypad. The output, by default pulses on for 90 seconds.
26 Alert (Latch)
The Alert output is activated when the control panel loses communication with one of the remote modules or
keypads.
27 Fire...

Page 104

Galaxy 3 Series Programming Manual
98
33 Warning (Latch)
The Warning output is activated by the first occurrence of a high (1200-1300Ω) and low (800-900Ω)
resistance reading on each of the system zones in a single 24 hour period: the activating zone is recorded in the
log.
NOTE:The time period finishes at midnight, not 24 hours from first activation.
Subsequent high and low resistance readings from the same zone on the same day do not activate the output if
it has been reset by a valid user code.
NOTE:If...

Page 105

Galaxy 3 Series Programming Manual
99
42 Illegal Code (Latch)
The Illegal Code is activated 60 seconds after an entry of a single Dual Code or a code which is entered
outwith the Timer A  and/or Timer B times assigned to it in menu option 42.1.4=CODES.User
Codes.Time Zone.
43 Max Tamp (Latch)
The MAX TAMP output is activated when a MAX, MicroMAX or MAX
3 tamper is activated.
44 Abort (Latch)
The ABORT output is activated when a valid code is entered during the Abort period on system entry.
45 Unset
The...

Page 106

Galaxy 3 Series Programming Manual
100
53 - Program Outputs (cont’d)
Link outputs can be activated by any of the link option sources. The operation of the Link output is depend-
ent on the Output Mode and Groups assigned to the output. The Groups assigned to the Link must have at
least one group common to the link output, if that output is to be activated. This feature can be used to multi-
ply the number of different link outputs available on the system.
NOTE:When a zone function is the source of  a...

Page 107

Galaxy 3 Series Programming Manual
101
77  Bell Test
This output activates when Bell Test is selected via menu 32. This causes the bell and strobe output to
activate. This output is normally used to activate a relay to cut power to the bell.
78  Comms Test (Pulse)
This output is used for remote routine inspection, via the downloader software. When a remote inspection is
carried out, this output will activate for 10 seconds in order to trigger the test input of an external comms
device.
53 - Program...

Page 108

Galaxy 3 Series Programming Manual
102
Option 54 – Links
The Links option offers a powerful method of interconnecting zones, output functions, codes, keypads, and
MAX modules. The links table is constructed by creating a link between one of the source types and a valid
destination type. Activating the source of a link activates the destination – this can be used to switch outputs
on and off to omit zones, codes, keypads and MAX modules from the system.
The links function allows MAX/MicroMAX/MAX
3...

Page 109

Galaxy 3 Series Programming Manual
103
8.If the link destination is d). Output Type and Groups have been enabled (refer to option 63=OP-
TIONS) then each link must be allocated to at least one group (use the A or B key to move between the
group blocks; press keys 1 – 8 to assign the relevant groups in each block) and press the ent key.
NOTE:The groups determine which of the assigned output type destinations the link activates.
9.The details of the assigned link are displayed.
NOTE:If the link is...

Page 110

Galaxy 3 Series Programming Manual
104
54 - Links (cont’d)
Table 24. Link destination
NOTE:
¹¹There are 16 Link timers in the system. These Link timers are triggered by the Latch and Reflex
timer destinations. Both the Latch and Reflex options operate the same set of Link timers. They just
start the timers in different ways. A Latch timer can restart the Link timer while it is running. A Reflex
timer cannot.
Destination Type* ModifierNotes
a) Not used - The link is not operational.
b) Zone Address -When...