Page 101
Galaxy 3 Series Programming Manual 95 09 Set (Reflex) The Set output is activated when the assigned groups on the system are set. This output is a Reflex output and follows the set and unset status of the groups. 10 Engineer (Reflex) The Engineer output is activated while the engineer mode is being accessed. 11 Spare (Latch) The Spare output has function: it is used to designate outputs that are not being used on the system. 12 Ready (Reflex) The Ready output is active when all zones in the system...
Page 102
Galaxy 3 Series Programming Manual 96 18 E/E Horn (Latch) The Entry/Exit Horn output has a dual function: • in an alarm condition its function is identical to that of the Horn output; • during the unsetting and setting of the system it is used to provide an indication on the status of the system. The indication states are as follows: • General Alarm - ON 500 msecs. OFF 500 msecs. • Clear to Exit -Continuous • Exit interrupted - ON 100 msecs. OFF 100 msecs. • 75% Exit Time - ON 200 msecs. OFF 200 msecs....
Page 103
Galaxy 3 Series Programming Manual 97 24 Batt Test This output is activated when a battery load test is in progress. Refer to option 61.1.4 = Diagnostics.Latest.PSU Comms. 25 Wrong CD This output is activated whenever a wrong code alarm occurs. That is, when six wrong codes in succession are entered at the keypad. The output, by default pulses on for 90 seconds. 26 Alert (Latch) The Alert output is activated when the control panel loses communication with one of the remote modules or keypads. 27 Fire...
Page 104
Galaxy 3 Series Programming Manual 98 33 Warning (Latch) The Warning output is activated by the first occurrence of a high (1200-1300Ω) and low (800-900Ω) resistance reading on each of the system zones in a single 24 hour period: the activating zone is recorded in the log. NOTE:The time period finishes at midnight, not 24 hours from first activation. Subsequent high and low resistance readings from the same zone on the same day do not activate the output if it has been reset by a valid user code. NOTE:If...
Page 105
Galaxy 3 Series Programming Manual 99 42 Illegal Code (Latch) The Illegal Code is activated 60 seconds after an entry of a single Dual Code or a code which is entered outwith the Timer A and/or Timer B times assigned to it in menu option 42.1.4=CODES.User Codes.Time Zone. 43 Max Tamp (Latch) The MAX TAMP output is activated when a MAX, MicroMAX or MAX 3 tamper is activated. 44 Abort (Latch) The ABORT output is activated when a valid code is entered during the Abort period on system entry. 45 Unset The...
Page 106
Galaxy 3 Series Programming Manual 100 53 - Program Outputs (cont’d) Link outputs can be activated by any of the link option sources. The operation of the Link output is depend- ent on the Output Mode and Groups assigned to the output. The Groups assigned to the Link must have at least one group common to the link output, if that output is to be activated. This feature can be used to multi- ply the number of different link outputs available on the system. NOTE:When a zone function is the source of a...
Page 107
Galaxy 3 Series Programming Manual 101 77 Bell Test This output activates when Bell Test is selected via menu 32. This causes the bell and strobe output to activate. This output is normally used to activate a relay to cut power to the bell. 78 Comms Test (Pulse) This output is used for remote routine inspection, via the downloader software. When a remote inspection is carried out, this output will activate for 10 seconds in order to trigger the test input of an external comms device. 53 - Program...
Page 108
Galaxy 3 Series Programming Manual 102 Option 54 – Links The Links option offers a powerful method of interconnecting zones, output functions, codes, keypads, and MAX modules. The links table is constructed by creating a link between one of the source types and a valid destination type. Activating the source of a link activates the destination – this can be used to switch outputs on and off to omit zones, codes, keypads and MAX modules from the system. The links function allows MAX/MicroMAX/MAX 3...
Page 109
Galaxy 3 Series Programming Manual 103 8.If the link destination is d). Output Type and Groups have been enabled (refer to option 63=OP- TIONS) then each link must be allocated to at least one group (use the A or B key to move between the group blocks; press keys 1 – 8 to assign the relevant groups in each block) and press the ent key. NOTE:The groups determine which of the assigned output type destinations the link activates. 9.The details of the assigned link are displayed. NOTE:If the link is...
Page 110
Galaxy 3 Series Programming Manual 104 54 - Links (cont’d) Table 24. Link destination NOTE: ¹¹There are 16 Link timers in the system. These Link timers are triggered by the Latch and Reflex timer destinations. Both the Latch and Reflex options operate the same set of Link timers. They just start the timers in different ways. A Latch timer can restart the Link timer while it is running. A Reflex timer cannot. Destination Type* ModifierNotes a) Not used - The link is not operational. b) Zone Address -When...