Galaxy 3 Series Programming Manual
145
Option 58 – Keypad
The keypads connected to the Galaxy control panel can be assigned individual attributes allowing each
keypad to respond in a particular way.
On selecting the Keypad option the details of the first keypad connected to the system are displayed.
The required keypad is selected by entering the keypad address or by using the A and B keys and then
pressing ent; the keypad displays 1=A-key. Press the A and B keys to select the required option and press...

Page 152

Galaxy 3 Series Programming Manual
146
2 = B-key
The programming of the B key is identical to that of the A key.
3 = Buzzer Mimic
This option determines whether the keypad buzzer mimics the function of the programmed keypad output
(refer to option 53 = PROGRAM OUTPUTS). The default function of the keypad output is Entry/Exit
Horn and the default Mimic defaults to On, therefore the keypad buzzer operates as an Entry/Exit Horn at
factory setting.
To disable the keypad buzzer from mimicking the output...

Page 153

Galaxy 3 Series Programming Manual
147
6 = Show Status
This option allows the keypad to display the set status of the groups. When Show Status is enabled, pressing
the 7 and # keys simultaneously when the normal banner is displayed indicates the group set status.
NOTE:The Show Status indicates the set conditions of groups when the system is set (keypad blank) or
unset (normal banner).  Show Status does not operate while engineer mode is accessed.
Pressing the 7 and # keys again toggles the display to...

Page 154

Galaxy 3 Series Programming Manual
148
59 - Quick Menu
n o i t p O u n e Mr e s U
e p y T
0se n o Z t i m O113. 2
1te S d e c r o F413. 2
2em i h C513. 2
3se n o Z y a l p s i D124. 2
4go L y a l p s i D224. 2
5tn i r P424. 2
6ts e T k l a W135. 2
7et a D
/ e m i T146. 2
8se d o C246. 2
9re m m u S346. 2
Option 59 – Quick Menu
The Galaxy quick menu consists of up to 10 menu options that are accessed by all type 2.3 (and above) user
codes that do not have a 7 assigned to their code type. This option...

Page 155

Galaxy 3 Series Programming Manual
149
61 - Diagnostics
Standby Time 8h Standby Time 8hStandby Time 8h Standby Time 8h
Standby Time 8h
Charge Time  4h Charge Time  4hCharge Time  4h Charge Time  4h
Charge Time  4h
Section 9:  Engineer 2
Option 61 – Diagnostics
This option allows several diagnostic tests to be run on the system, providing valuable information on the
operational status of the Galaxy and connected modules.
The Galaxy diagnostic option performs a number of checks including:
the communication...

Page 156

Galaxy 3 Series Programming Manual
150
3. The status of the AC power and battery are displayed. Also, if available, the lowest voltage during the
last battery load test.
4. This displays the battery charging voltage and current information. The panel and Galaxy 3 Series
PSU will also display the current charging state after Battery. This is either Charging or Charged.
5. This displays the battery load test. It is only available for the on-board PSU.
Pressing the ent key again initiates a system wide...

Page 157

Galaxy 3 Series Programming Manual
151
61 - Diagnostics (cont’d)
3 = Record
This option initiates a baseline check of areas 1 to 7 in the table above. The dispay prompts the user to press
the * key to continue with the diagnostic check.
4 = Checks
This option allows each of the areas 1 to 9 listed in the table above to be included or excluded from the
baseline recording. All areas are included by default.
5 = Print
This option allows the stored baseline data to be printed using either the printer module...

Page 158

Galaxy 3 Series Programming Manual
152
Option 62 – Full Test
The Full Test option allows two zones to be selected and tested under full set conditions. Activating the
selected zone results in a full alarm condition, including remote signalling. Constantly active zones (Security,
24 Hours, PA, Fire) remain active throughout the Full Test; an activation generates the appropriate local or
full alarm depending on the zone.
On selecting the Full Test option, the address and function of the first zone on the...

Page 159

Galaxy 3 Series Programming Manual
153
Option 63 – Options
The Options   function allows the Galaxy to be divided into group subsystems and also allows the MAX
proximity access control readers to be integrated into the system.
63 - Options
Figure 10. Options
Options
1 = Groups  
1 = Group Mode0 = Disabled
1 = Enabled
2 = Setting Logic
A/B to move to group and ent to select.
Number keys to toggle:
- = status of group unimportant
S = Group must be set to allow group to set.
3 = Group Name
A/B to move to...

Page 160

Galaxy 3 Series Programming Manual
154
1=Groups
On selecting Options, the keypad displays 1 = Groups; press the ent key to select this function.
1 = Group Mode
This option is used to enable the Groups function (default is 0 = Disabled).  When enabled, the system
options that are eligible for group programming are then made available throughout the menu, otherwise they
do not appear.
Enabling Groups
On selecting 1 = Enabled, press the ent key to accept the programming and return to the previous menu...