Galaxy 3 Series Programming Manual 155 2 = Setting Logic The Setting Logic option restricts a group from setting by determining which other groups must be set before it can set. For example, group 1 may be prohibited for setting unless groups 3, 7 are already set. The Set- ting Logic is individually defined for each group. Programming Setting Logic On selecting the Setting Logic option, group 1 is displayed. Use the A or B keys to move to the required group or directly select it by pressing the...
Page 162
Galaxy 3 Series Programming Manual 156 3 = Group Name This option is used to assign a name of up to 12 characters to each of the groups. This name is assembled from the character set and/or library options. On selecting the Group Name option, the name currently assigned to group 1 is displayed. All group names default to Group X (where X is the group number). Use the A or B keys to move to the required group or directly select it by pressing the required group number; press the ent key to access the...
Page 163
Galaxy 3 Series Programming Manual 157 Group Name Display When viewing the groups assigned to an option, for example user code or outputs, simultaneously pressing the # and 7 keys displays the groups individually. The keypad displays the group number, name and the status of the particular option being displayed. Press the # key to toggle the status of the group. To move to another group press the A or B keys or enter the number of the group directly. Notes on Groups 1. All zones default to group 1. 2....
Page 164
Galaxy 3 Series Programming Manual 158 2 = MAX Address The address and the on-line or standalone status of the MAX Modules are assigned and modified using this option. On selecting MAX Address the Galaxy searches for the MAX with the highest address. The Galaxy 48 prompts for the AB line (1-1); the Galaxy 144 prompts for the AB line (1-2); the Galaxy 520 prompts for the AB line (1-4) that is to be searched. Select the line and press the ent key. On locating the MAX, the keypad prompts for the TYPE of...
Page 165
Galaxy 3 Series Programming Manual 159 Select the required MAX/MicroMAX address using the A and B keys or by entering the MAX/MicroMAX address directly and pressing the ent key. The first MAX parameter, 1 = Description is displayed. Use the A or B keys to move to the required parameter and press the ent key. 1 = Descriptor This option is used to assign a name of up to 12 characters to each of the MAX modules. This name is assem- bled from the character set and/or library options. On selecting the...
Page 166
Galaxy 3 Series Programming Manual 160 3 = Open Timeout This is the period following the user card swipe that the door can remain open when gaining access. If the door remains open longer than the period assigned to the Open Timeout, then an alarm occurs. NOTE:If the Open Timeout is programmed as 0 seconds, then the door can remain open indefinitely without resulting in an alarm being activated. On entering the Open Timeout parameter, the current value is displayed; assign the required time within the...
Page 167
Galaxy 3 Series Programming Manual 161 In access mode access will be granted if there are common groups between the card and the MAX reader and all the groups assigned to the card are unset. For the card held function, the groups affected by the func- tion will be all the groups assigned to the card, so long as there is at least one common group between the card and the MAX. Common Group Restriction The group restrictions can be enhanced further by pressing the 7 key when assigning group in Group...
Page 168
Galaxy 3 Series Programming Manual 162 5 = Emergencies This option allows each individual MAX/MicroMAX/MAX3 unit to be configured to respond to fire zones in a given set of groups. Upon the opening of a fire zone in one of the groups allocated to the MAX/MicroMAX/ MAX 3, the MAX/MicroMAX/MAX3 will trigger the door strike and hold the door open until the system is reset. All the MAX/MicroMAX/MAX 3 LEDs will light and the buzzer will sound. Closing the fire zone will have no effect - the MAX/MicroMAX/MAX 3...
Page 169
Galaxy 3 Series Programming Manual 163 Option 64 – Assemble Zone The Assemble Zones option allows 2 zone functions to be customised to the user’s requirements; these are the 1 Custom-A and 2 Custom-B zones. Once a custom zone function has been assembled, it is assigned to zones using option 52 = PROGRAM ZONES. Programming a Custom Zone The flexibility of this menu option allows for an extensive range of possibilities. It is therefore important that the engineer is fully aware of the system and has a...
Page 170
Galaxy 3 Series Programming Manual 164 1 = Outputs Any of the available output types can be assigned to the custom zone. On selecting this attribute the 01=BELLS output type is displayed along with it status; the default status is disabled. The status indicates the conditions under which the custom zone activates the output. To assign the output type status press the # key, this toggles between each of the status settings: 1. Disabledthe output is not activated by the custom zone, 2 Setthe output is...