Page 141

Galaxy 3 Series Programming Manual
135
8 = Protocol
The Ethernet module is capable if signalling using either TCP (Transmission Control Protocol) or UDP (Uni-
versal Datagram Protocol). Earlier versions of Ethernet module, Alarm Monitoring and Galaxy Gold only
supported the TCP protocol.
NOTE:If communicating with V3.26 Alarm Monitoring or V6.26 Galaxy Gold the TCP option should be
selected.
If encryption is required for alarm signalling the UDP protocol should be selected.
Irrespective of the...

Page 142

Galaxy 3 Series Programming Manual
136
2 = Manager Authorize
This option requires authorization from the site manager in order to gain remote access to the Galaxy panel.
There are two methods that the manager can use to enable access to the Galaxy via Galaxy Gold.
Timed Access – Galaxy Gold must access the Galaxy panel within 40 minutes of this option being enabled by
the manager (Option 47.1.2.0). Once connected there is no time limit on the access period. On terminating the
connection, Galaxy Gold can...

Page 143

Galaxy 3 Series Programming Manual
137
Note: if the receiver option is programmed as Dual then a successful transmission must be made to both
primary and secondary to be considered a successful transmission.
07 = Line Fail
The line fail option controls which Ethernet connections are monitored. The Ethernet module can be pro-
grammed to monitor both the network availability and the programmed transmission paths between the
Ethernet module and receiver applications.
Line fail events (whether network or...

Page 144

Galaxy 3 Series Programming Manual
138
4 = Any
When selected the Ethernet module monitors all transmission paths. If a supervision failure is detected in any
of the paths a line fail condition will be activated.
5 = All
When selected the Ethernet module monitors all transmission paths. If a supervision failure is detected in all of
the paths a line fail condition will be activated.
08 = SIA Control
When using the SIA control command protocol for integration purposes the IP address of the computer
sending...

Page 145

Galaxy 3 Series Programming Manual
139
1 = On
If selected encryption is enabled for communications between the Ethernet module and remote PC using the
SIA control command protocol. In order for data to be received when this option is selected the receiver must
support decryption.
4 = Alarm Mon.
This option controls encryption for the Alarm Monitoring alarm transmission paths. Default is disabled.
0 = Off
If selected encryption is disabled for the Alarm Monitoring alarm transmission paths.
1 = On
If...

Page 146

Galaxy 3 Series Programming Manual
140
5 = Ext Telecoms
The external telecom module has the same menu structure and function as the internal telecoms with the
following exceptions:
11 Fail to Comm
 This is controlled by the number of attempts and not time.
15 Backup Module
This option allows another module to become the primary communication module if a line fail is detected on
the external telecoms module. There are 6 options:
1 = Off;  2 = Ext RS232;  3 = ISDN;  4 = Ethernet;  5 = Int Telecoms;  6 =...

Page 147

Galaxy 3 Series Programming Manual
141
6 = Int RS232 Port56 - Communications (cont’d)
Figure 9. Internal RS232  Programming structure
The Galaxy 3 Series  supports an on-board RS232 serial port. This ports is:
• Programmable independently from the panel.
• Speed configurable from 300 to 56K bps (or highest practical speed).
• Able to configure data length, parity and stop bits.
• Supervised (optional via programming).
The RS232 port is configurable to support:
• Connection to a PC.
• Connection to a...

Page 148

Galaxy 3 Series Programming Manual
142
1 Mode
The Mode option allows selection of the method of connection to the PC:
1 = Printer
This option is selected if the Galaxy is communicating with a serial printer.
2 = Direct
This mode is selected if the Galaxy panel and PC are located in close proximity to one another and can inter-
face via an RS232 cable.
3 = Modem
This mode is selected if the RS232 is communicating, via a modem and telephone line, with a remote PC.
1 = Telephone No.
The telephone number of...

Page 149

Galaxy 3 Series Programming Manual
143
3 Account No.
This is the site identifier. A unique account number must be entered, this can be up to a maximum of six digits.
The B key is used to erase an existing number. Each press deletes the last digit displayed.
4 Comms Setup
Serial communication between the on-board R232 port and a remote PC require the following 4 elements.
1 = Baud Rate
This is the number of bits  that occur each second (bps). This can be set as follows:
1=300; 2=600; 3=1200; 4=2400;...

Page 150

Galaxy 3 Series Programming Manual
144
Option 57 – System Print
The System Print option allows the details of the system programming to be printed. There are 2 options for
the printer output:
  1 = Printer Module
  2 = Int RS232 1
From either option, the specific details of one or all of the menu options in the following table can be selected:
57 - System Print
n o i t p O u n e M.o N u n e M
1 0at a D m e t s y S32
2 0se d o C24
3 0sr e t e m a r a P15
4 0se n o Z25
5 0st u p t u O35
6 0sk n i L45
7 0no...
Start reading Honeywell Galaxy 3 User Manual

Related Manuals for Honeywell Galaxy 3 User Manual

All Honeywell manuals