Page 141
Galaxy 3 Series Programming Manual 135 8 = Protocol The Ethernet module is capable if signalling using either TCP (Transmission Control Protocol) or UDP (Uni- versal Datagram Protocol). Earlier versions of Ethernet module, Alarm Monitoring and Galaxy Gold only supported the TCP protocol. NOTE:If communicating with V3.26 Alarm Monitoring or V6.26 Galaxy Gold the TCP option should be selected. If encryption is required for alarm signalling the UDP protocol should be selected. Irrespective of the...
Page 142
Galaxy 3 Series Programming Manual 136 2 = Manager Authorize This option requires authorization from the site manager in order to gain remote access to the Galaxy panel. There are two methods that the manager can use to enable access to the Galaxy via Galaxy Gold. Timed Access – Galaxy Gold must access the Galaxy panel within 40 minutes of this option being enabled by the manager (Option 47.1.2.0). Once connected there is no time limit on the access period. On terminating the connection, Galaxy Gold can...
Page 143
Galaxy 3 Series Programming Manual 137 Note: if the receiver option is programmed as Dual then a successful transmission must be made to both primary and secondary to be considered a successful transmission. 07 = Line Fail The line fail option controls which Ethernet connections are monitored. The Ethernet module can be pro- grammed to monitor both the network availability and the programmed transmission paths between the Ethernet module and receiver applications. Line fail events (whether network or...
Page 144
Galaxy 3 Series Programming Manual 138 4 = Any When selected the Ethernet module monitors all transmission paths. If a supervision failure is detected in any of the paths a line fail condition will be activated. 5 = All When selected the Ethernet module monitors all transmission paths. If a supervision failure is detected in all of the paths a line fail condition will be activated. 08 = SIA Control When using the SIA control command protocol for integration purposes the IP address of the computer sending...
Page 145
Galaxy 3 Series Programming Manual 139 1 = On If selected encryption is enabled for communications between the Ethernet module and remote PC using the SIA control command protocol. In order for data to be received when this option is selected the receiver must support decryption. 4 = Alarm Mon. This option controls encryption for the Alarm Monitoring alarm transmission paths. Default is disabled. 0 = Off If selected encryption is disabled for the Alarm Monitoring alarm transmission paths. 1 = On If...
Page 146
Galaxy 3 Series Programming Manual 140 5 = Ext Telecoms The external telecom module has the same menu structure and function as the internal telecoms with the following exceptions: 11 Fail to Comm This is controlled by the number of attempts and not time. 15 Backup Module This option allows another module to become the primary communication module if a line fail is detected on the external telecoms module. There are 6 options: 1 = Off; 2 = Ext RS232; 3 = ISDN; 4 = Ethernet; 5 = Int Telecoms; 6 =...
Page 147
Galaxy 3 Series Programming Manual 141 6 = Int RS232 Port56 - Communications (cont’d) Figure 9. Internal RS232 Programming structure The Galaxy 3 Series supports an on-board RS232 serial port. This ports is: • Programmable independently from the panel. • Speed configurable from 300 to 56K bps (or highest practical speed). • Able to configure data length, parity and stop bits. • Supervised (optional via programming). The RS232 port is configurable to support: • Connection to a PC. • Connection to a...
Page 148
Galaxy 3 Series Programming Manual 142 1 Mode The Mode option allows selection of the method of connection to the PC: 1 = Printer This option is selected if the Galaxy is communicating with a serial printer. 2 = Direct This mode is selected if the Galaxy panel and PC are located in close proximity to one another and can inter- face via an RS232 cable. 3 = Modem This mode is selected if the RS232 is communicating, via a modem and telephone line, with a remote PC. 1 = Telephone No. The telephone number of...
Page 149
Galaxy 3 Series Programming Manual 143 3 Account No. This is the site identifier. A unique account number must be entered, this can be up to a maximum of six digits. The B key is used to erase an existing number. Each press deletes the last digit displayed. 4 Comms Setup Serial communication between the on-board R232 port and a remote PC require the following 4 elements. 1 = Baud Rate This is the number of bits that occur each second (bps). This can be set as follows: 1=300; 2=600; 3=1200; 4=2400;...
Page 150
Galaxy 3 Series Programming Manual 144 Option 57 – System Print The System Print option allows the details of the system programming to be printed. There are 2 options for the printer output: 1 = Printer Module 2 = Int RS232 1 From either option, the specific details of one or all of the menu options in the following table can be selected: 57 - System Print n o i t p O u n e M.o N u n e M 1 0at a D m e t s y S32 2 0se d o C24 3 0sr e t e m a r a P15 4 0se n o Z25 5 0st u p t u O35 6 0sk n i L45 7 0no...