Honeywell Galaxy 3 User Manual
Here you can view all the pages of manual Honeywell Galaxy 3 User Manual. The Honeywell manuals for Control panel are available online for free. You can easily download all the documents as PDF.
Page 201
Galaxy 3 Series Programming Manual C-1 Appendix C: SIA Event Structure SIA Event Structure t n e v E e p y TA I S L E V E L. C C A k c o l Bt a m r o F k c o l B A T A D ) e d o c k c o l b N () e d o c k c o l b A ( t a m r o F k c o l B i i c s Ano i t a n a l p x E E N O Z4, 3xx x x x x #zz z z V E / x x i r / x x : x x i t Ndd d d d d d d d d d d d d d d i i i i i i i i s e e e e e e e e e Act e h c t i w s y e k , d e m r a l a r o t c e t e D 2xx x x x x #zz z z V E / x x i r / x x : x x i t N...
Page 203
Galaxy 3 Series Programming Manual D-1 Appendix D: Event Log Messages Event Log NOTE:M = Mandatory. NM = Non-Mandatory NOTE:A plus (+) means an event has started. A negative (-) means an event has finished. KEYPAD TEXT DESCRIPTION Trigger Event 0001 + CU-BATT Control Unit Standby Battery Low has occurred (battery voltage below 10.5 Vd.c.).13. Elec Status 20. FaultM 0001 - CU-BATT Control Unit Standby Battery Low has finished (battery voltage now above 10.5 Vd.c.). 13. Elec. Status M 0002 + CU-AC...
Page 204
Galaxy 3 Series Programming Manual D-2 Event Log (cont’d) NOTE:M = Mandatory. NM = Non-Mandatory NOTE:A plus (+) means an event has started. A negative (-) means an event has finished. KEYPAD TEXT DESCRIPTION Trigger Event DURESS Duress code has been entered. 1. PA/Duress M ENG ASSEM Engineering Assemble Zone menu (Menu Option 64) has been accessed. 14. Menu Access M ENG CHECK Engineering Pre-Check menu (Menu Option 66) has been accessed. 14. Menu Access M ENG DIAG Engineering Diagnostics menu (Menu...
Page 205
Galaxy 3 Series Programming Manual D-3 NOTE:M = Mandatory. NM = Non-Mandatory NOTE:A plus (+) means an event has started. A negative (-) means an event has finished. Event Log (cont’d) KEYPAD TEXT DESCRIPTION Trigger Event +FINAL Final zone activated (opened) during Setting/Unsetting procedure or when Set. 7. Set Fault NM –FINAL Final zone de-activated (closed) during Setting/Unsetting procedure or when Set. 7. Set Fault NM FIRE Fire zone activated (opened). 6. Fire M FOB REJCT Illegal fobNone M FORCE...
Page 206
Galaxy 3 Series Programming Manual D-4 Event Log (cont’d) NOTE:M = Mandatory. NM = Non-Mandatory NOTE:A plus (+) means an event has started. A negative (-) means an event has finished. KEYPAD TEXT DESCRIPTION Trigger Event LOC WRITE Diagnostics local write event None M +LOCKTIMER Lockout timer activated.No ne NM –LOCKTIMER Lockout timer de-activated. None NM +LOG Log zone activated (opened). 16. Log NM –LOG Log zone de-activated (closed). 16. Log NM LOG 90% Event log 90% fullAlways TR NM LOG DELAY Log...
Page 207
Galaxy 3 Series Programming Manual D-5 Event Log (cont’d) NOTE:M = Mandatory. NM = Non-Mandatory NOTE:A plus (+) means an event has started. A negative (-) means an event has finished. KEYPAD TEXT DESCRIPTION Trigger Event PA DEL/SL PA Delayed Silent zone activated (opened). 1. PA/Duress M PA DELAY PA Delayed zone activated (opened). 1. PA/Duress M PA RESET PA Reset has occurred. 1. PA/Duress NM PA SILENT PA Silent zone activated (opened). 1. PA/Duress M PA UNSET PA Unset zone activated while group in...
Page 208
Galaxy 3 Series Programming Manual D-6 Event Log (cont’d) NOTE:M = Mandatory. NM = Non-Mandatory NOTE:A plus (+) means an event has started. A negative (-) means an event has finished. KEYPAD TEXT DESCRIPTION Trigger Event RM ACCESS Remote Access zone activated 14. Menu Access NM +SEC FINAL Security Final zone activated (opened) 4. Security M -S E C F INA L S e c uri ty F i na l zo ne c lo s e d (c lo s e d )4. Security 18. Zone restoralM +SECURITY Security zone activated (opened). 4. Security M...
Page 209
Galaxy 3 Series Programming Manual E-1 Appendix E: Site Data Storage Also referred to as the ‘dumpbox mode’, this function allows the Grade 3 panel to emulate the behaviour of an External RS232 module, which can then be attached to another Galaxy panel, including Legacy panels of previous versions, to copy the programming data. For the purposes of this document, the Grade 3 panel in use is referred to as the Grade 3 panel. The panel to which the Grade 3 panel is connected is referred to as the Legacy...
Page 210
Galaxy 3 Series Programming Manual E-2 Data Storage (cont’d) Using Storage Mode On the Legacy panel, enter and leave Engineer mode, so the External RS232 module is recognised. Then re- enter Engineer mode to use the storage mode facilities. On the Legacy panel, enter menu 56.2.4=Communications.RS232.Copy/Overwrite. To copy the programming data FROM the Legacy panel TO the Grade 3 panel, select 1=Copy Site. To copy the programming data FROM the Grade 3 panel TO the Legacy panel, select 2=Overwrite Site....