Galaxy 3 Series Programming Manual
C-1
Appendix C:  SIA  Event Structure
SIA Event Structure
t n e v E
e p y TA I S
L E V E L. C C A
k c o l Bt a m r o F k c o l B A T A D
) e d o c k c o l b N () e d o c k c o l b A ( t a m r o F k c o l B i i c s Ano i t a n a l p x E
E N O Z4, 3xx x x x
x #zz z z V E / x x i r / x x : x x i t Ndd d d d d d d d d d d d d d d i i i i i i i i s e e e e e e e e e Act e h c t i w s y e k , d e m r a l a r o t c e t e D
2xx x x x x #zz z z V E / x x i r / x
x : x x i t N...

Page 202

Galaxy 3 Series Programming Manual
C-2 

Page 203

Galaxy 3 Series Programming Manual
D-1
Appendix D:  Event Log Messages
Event Log
NOTE:M = Mandatory.  NM = Non-Mandatory
NOTE:A plus (+) means an event has started. A negative (-) means an event has finished.
KEYPAD TEXT DESCRIPTION Trigger Event
0001 + CU-BATT Control Unit Standby Battery Low has occurred (battery voltage below 10.5 Vd.c.).13. Elec Status
20. FaultM
0001 - CU-BATT Control Unit Standby Battery Low has finished (battery voltage now above 10.5 Vd.c.). 13. Elec. Status M
0002 + CU-AC...

Page 204

Galaxy 3 Series Programming Manual
D-2
Event Log (cont’d)
NOTE:M = Mandatory.  NM = Non-Mandatory
NOTE:A plus (+) means an event has started. A negative (-) means an event has finished.
KEYPAD TEXT DESCRIPTION Trigger Event
DURESS Duress code has been entered. 1. PA/Duress M
ENG ASSEM Engineering Assemble Zone menu (Menu Option 64) has been accessed. 14. Menu Access M
ENG CHECK Engineering Pre-Check menu (Menu Option 66) has been accessed. 14. Menu Access M
ENG DIAG Engineering Diagnostics menu (Menu...

Page 205

Galaxy 3 Series Programming Manual
D-3
NOTE:M = Mandatory.  NM = Non-Mandatory
NOTE:A plus (+) means an event has started. A negative (-) means an event has finished.
Event Log (cont’d)
KEYPAD TEXT DESCRIPTION Trigger Event
+FINAL Final zone activated (opened) during Setting/Unsetting procedure or when Set. 7. Set Fault NM
–FINAL Final zone de-activated (closed) during Setting/Unsetting procedure or when Set. 7. Set Fault NM
FIRE Fire zone activated (opened). 6. Fire M
FOB REJCT Illegal fobNone M
FORCE...

Page 206

Galaxy 3 Series Programming Manual
D-4
Event Log (cont’d)
NOTE:M = Mandatory.  NM = Non-Mandatory
NOTE:A plus (+) means an event has started. A negative (-) means an event has finished.
KEYPAD TEXT DESCRIPTION Trigger Event
LOC WRITE Diagnostics local write event None M
+LOCKTIMER Lockout timer activated.No ne NM
–LOCKTIMER Lockout timer de-activated. None NM
+LOG Log zone activated (opened). 16. Log NM
–LOG Log zone de-activated (closed). 16. Log NM
LOG 90% Event log 90% fullAlways TR NM
LOG DELAY Log...

Page 207

Galaxy 3 Series Programming Manual
D-5
Event Log (cont’d)
NOTE:M = Mandatory.  NM = Non-Mandatory
NOTE:A plus (+) means an event has started. A negative (-) means an event has finished.
KEYPAD TEXT DESCRIPTION Trigger Event
PA DEL/SL PA Delayed Silent zone activated (opened). 1. PA/Duress M
PA DELAY PA Delayed zone activated (opened). 1. PA/Duress M
PA RESET PA Reset has occurred. 1. PA/Duress NM
PA SILENT PA Silent zone activated (opened). 1. PA/Duress M
PA UNSET PA Unset  zone activated while group in...

Page 208

Galaxy 3 Series Programming Manual
D-6
Event Log (cont’d)
NOTE:M = Mandatory.  NM = Non-Mandatory
NOTE:A plus (+) means an event has started. A negative (-) means an event has finished.
KEYPAD TEXT DESCRIPTION Trigger Event
RM ACCESS Remote Access zone activated 14. Menu Access NM
+SEC FINAL Security Final zone activated (opened) 4. Security M
-S E C  F INA L S e c uri ty F i na l zo ne  c lo s e d  (c lo s e d )4. Security
18. Zone restoralM
+SECURITY Security zone activated (opened). 4. Security M...

Page 209

Galaxy 3 Series Programming Manual
E-1
Appendix E:  Site Data Storage
Also referred to as the ‘dumpbox mode’, this function allows the Grade 3 panel to emulate the behaviour of
an External RS232 module, which can then be attached to another Galaxy panel, including Legacy panels of
previous versions, to copy the programming data.
For the purposes of this document, the Grade 3 panel in use is referred to as the Grade 3 panel. The panel to
which the Grade 3 panel is connected is referred to as the Legacy...

Page 210

Galaxy 3 Series Programming Manual
E-2
Data Storage (cont’d)
Using Storage Mode
On the Legacy panel, enter and leave Engineer mode, so the External RS232 module is recognised. Then re-
enter Engineer mode to use the storage mode facilities.
On the Legacy panel, enter menu 56.2.4=Communications.RS232.Copy/Overwrite.
To copy the programming data FROM the Legacy panel TO the Grade 3 panel, select 1=Copy Site. To
copy the programming data FROM the Grade 3 panel TO the Legacy panel, select 2=Overwrite Site....
Start reading Honeywell Galaxy 3 User Manual

Related Manuals for Honeywell Galaxy 3 User Manual

All Honeywell manuals