Page 131

8 - 13
Straight 2 of 5 IATA (two-bar start/stop)

Straight 2 of 5 IATA On/Off
Straight 2 of 5 IATA Redundancy
If you are encountering errors when reading Straight 2 of 5 IATA bar codes, you may want to adjust the redundancy count.  
Redundancy adjusts the number of times a bar code is decoded before transmission, which may reduce the number of 
errors.  Note that the higher the redundancy count, the longer it will take to decode the bar code.  To adjust the redundancy, 
scan the Straight 2 of 5 IATA...

Page 132

8 - 14
Matrix 2 of 5

Matrix 2 of 5 On/Off
Matrix 2 of 5 Check Character
No Check Character indicates that the scanner reads and transmits bar code data with or without a check character.
When Check Character is set to Validate, but Don’t Transmit, the unit only reads Matrix 2 of 5 bar codes printed with a 
check character, but will not transmit the check character with the scanned data.  
When Check Character is set to Validate and Transmit, the scanner only reads Matrix 2 of 5 bar codes printed with a...

Page 133

8 - 15
Matrix 2 of 5 Message Length
Scan the bar codes below to change the message length.  Refer to Message Length Description (page 8-1) for additional 
information.  Minimum and Maximum lengths = 1-80.  Minimum Default = 3, Maximum Default = 80.
Code 11

Code 11 On/Off
Check Digits Required
These options set whether 1 or 2 check digits are required with Code 11 bar codes.  Auto Select Check Digits determines 
the number of check digits based on the length of the bar code.  If the bar code is 10 digits...

Page 134

8 - 16
Check Digit Validation
When Check Character is set to Validate and Transmit, the scanner will only read Code 11 bar codes printed with the 
specified type check character(s), and will transmit the character(s) at the end of the scanned data.
Code 11 Redundancy
If you are encountering errors when reading Code 11 bar codes, you may want to adjust the redundancy count.  Redun-
dancy adjusts the number of times a bar code is decoded before transmission, which may reduce the number of errors.  
Note...

Page 135

8 - 17
Code 128

Code 128 On/Off
128 Group Separator Output
If you wish to transmit embedded FNC1 characters as group separators (1B hex) with your Code 128 bar code output, scan 
the On bar code.  When Off is scanned, nothing is transmitted for FNC1 characters.  Default =Off.
Code 128 Redundancy
If you are encountering errors when reading Code 128 bar codes, you may want to adjust the redundancy count.  Redun-
dancy adjusts the number of times a bar code is decoded before transmission, which may reduce...

Page 136

8 - 18
Code 128 Message Length
Scan the bar codes below to change the message length.  Refer to Message Length Description (page 8-1) for additional 
information.  Minimum and Maximum lengths = 1-80.   Minimum Default = 3, Maximum Default = 80.
ISBT 128 Concatenation
In 1994 the International Society of Blood Transfusion (ISBT) ratified a standard for communicating critical blood informa-
tion in a uniform manner.  The use of ISBT formats requires a paid license. The ISBT 128 Application Specification...

Page 137

8 - 19
ISBT 128 Predefined Concatenation Sequences
Note: You must enable Code 128 and ISBT 128 to use this feature.
The following bar codes are used to select the pre-defined ISBT 128 Concatenation Sequence you wish to use.  Once you 
have selected the concatenation sequence, use ISBT 128 Predefined Concatenation Sequences On/Off to enable this fea-
ture.  Default = Donation ID Number (001)
and ABO/RhD Blood Groups (002).
ISBT 128 Predefined Concatenation Sequences On/Off
The following selections allow...

Page 138

8 - 20
Default = Off.
ISBT 128 User-Defined Concatenation Sequences
Note: You must enable Code 128 and ISBT 128 to use this feature.
The following bar codes are used to create a custom ISBT 128 Concatenation Sequence.  Select the identifiers you want to 
transmit in the 1st and 2nd positions, both left and right.  Refer to the ISBT 128 Standard Technical Specification for the list 
of data identifiers.
Use the ASCII Conversion Chart (Code Page 1252), page A-2, to find the characters needed for the...

Page 139

8 - 21
ISBT 128 User-Defined Concatenation Sequences On/Off
The following selections allow you to enable or require the User-Defined ISBT 128 Concatenation Sequences.  
If you scan Off, the User-Defined concatenation sequences are disabled.
If you scan the Allow User-Defined Sequence code, then the scanner will output only the data combination specified in 
the User-Defined concatenation sequence you created.  
If you scan the Require User-Defined Sequence code, the data combination specified in the...

Page 140

8 - 22
Transmit Identifiers
You may disable the transmission of the ISBT Code 128 data identifiers by scanning Off.  When this selection is Off, the 
first 2 data (ID) characters are removed from the data stream unless the ISBT code contains the Donation Identification 
Number identifiers.  If the code contains the Donation Identification Number identifiers, only the first ID character is 
removed from the Donation Identification Number.  The second character is transmitted as normal data.  Default =...